The optimal placement of switching devices on rural medium-voltage systems

Bibliography: leaves 104-106. === Electricity is supplied to rural areas by radial networks operating for example at 11 or 22 kV. A problem with radial networks is that faults on the feeders result in the loss of electricity supply to all customers if they are not sectionalised. Some radial networks...

Full description

Bibliographic Details
Main Author: Pitamber, Neemesh
Other Authors: Dingley, Charles
Format: Dissertation
Language:English
Published: University of Cape Town 2014
Subjects:
Online Access:http://hdl.handle.net/11427/5126
id ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-5126
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-51262020-12-10T05:11:16Z The optimal placement of switching devices on rural medium-voltage systems Pitamber, Neemesh Dingley, Charles Electrical Engineering Bibliography: leaves 104-106. Electricity is supplied to rural areas by radial networks operating for example at 11 or 22 kV. A problem with radial networks is that faults on the feeders result in the loss of electricity supply to all customers if they are not sectionalised. Some radial networks emanating from one feeder from the sub-station may consist of up to 300 km of line, taking into account spurs, which makes fault detection difficult and increases customer outage time. Protective devices such as reclosers, sectionalisers and fuses are place on distribution systems to reduce the number of customers that will not have service at one time or another due to any fault on the system. There do not appear to be clear rules with regard to the placement of these protective devices. With the installed cost of devices such as sectionalisers bieng over fifty thousand rand, this is naturally of concern to a power utility. 2014-07-31T10:54:06Z 2014-07-31T10:54:06Z 2001 Master Thesis Masters MSc http://hdl.handle.net/11427/5126 eng application/pdf University of Cape Town Faculty of Engineering and the Built Environment Department of Electrical Engineering
collection NDLTD
language English
format Dissertation
sources NDLTD
topic Electrical Engineering
spellingShingle Electrical Engineering
Pitamber, Neemesh
The optimal placement of switching devices on rural medium-voltage systems
description Bibliography: leaves 104-106. === Electricity is supplied to rural areas by radial networks operating for example at 11 or 22 kV. A problem with radial networks is that faults on the feeders result in the loss of electricity supply to all customers if they are not sectionalised. Some radial networks emanating from one feeder from the sub-station may consist of up to 300 km of line, taking into account spurs, which makes fault detection difficult and increases customer outage time. Protective devices such as reclosers, sectionalisers and fuses are place on distribution systems to reduce the number of customers that will not have service at one time or another due to any fault on the system. There do not appear to be clear rules with regard to the placement of these protective devices. With the installed cost of devices such as sectionalisers bieng over fifty thousand rand, this is naturally of concern to a power utility.
author2 Dingley, Charles
author_facet Dingley, Charles
Pitamber, Neemesh
author Pitamber, Neemesh
author_sort Pitamber, Neemesh
title The optimal placement of switching devices on rural medium-voltage systems
title_short The optimal placement of switching devices on rural medium-voltage systems
title_full The optimal placement of switching devices on rural medium-voltage systems
title_fullStr The optimal placement of switching devices on rural medium-voltage systems
title_full_unstemmed The optimal placement of switching devices on rural medium-voltage systems
title_sort optimal placement of switching devices on rural medium-voltage systems
publisher University of Cape Town
publishDate 2014
url http://hdl.handle.net/11427/5126
work_keys_str_mv AT pitamberneemesh theoptimalplacementofswitchingdevicesonruralmediumvoltagesystems
AT pitamberneemesh optimalplacementofswitchingdevicesonruralmediumvoltagesystems
_version_ 1719369859768254464