Three-phase five limb transformer responses to geomagnetically induced currents

Geomagnetically induced currents (GIC) are quasi-DC currents that result from space weather events arising from the sun. The sun ejects hot plasma in a concept termed ‘coronal mass ejections' which is directed towards the earth. This plasma interferes with the magnetic field of the magnetospher...

Full description

Bibliographic Details
Main Author: Murwira, Talent Tafadzwa
Other Authors: Oyedokun, David
Format: Dissertation
Language:English
Published: Faculty of Engineering and the Built Environment 2021
Subjects:
Online Access:http://hdl.handle.net/11427/33892
id ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-33892
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-338922021-09-16T05:08:52Z Three-phase five limb transformer responses to geomagnetically induced currents Murwira, Talent Tafadzwa Oyedokun, David Folly, Komla Engineering Geomagnetically induced currents (GIC) are quasi-DC currents that result from space weather events arising from the sun. The sun ejects hot plasma in a concept termed ‘coronal mass ejections' which is directed towards the earth. This plasma interferes with the magnetic field of the magnetosphere and ionosphere, and the magnetic field is subsequently distorted. The distortions in these regions results in the variation of potential on the earth's surface and distortions in the earth's magnetic field. The potential difference between two points on the earth's surface leads to the flow of direct current (DC) of very low frequency in the range 0.001 ~ 0.1 Hz. Geomagnetically induced currents enter into the power system through grounded neutrals of power transformers. The potential effects of GIC on transformers are asymmetrical saturation, increased harmonics, noise, magnetization current, hot spot temperature rise and reactive power consumption. Transformer responses to GIC was investigated in this research focussing on a three-phase fivelimb (3p5L) transformer. Practical tests and simulations were conducted on 15 kVA, 380/380 V, and 3p5L transformers. The results were extended to large power transformers in FEM using equivalent circuit parameters to show the response of grid-level transformers. A review of literature on the thresholds of GIC that can initiate damage in power transformers was also done and it was noted that small magnitudes of DC may cause saturation and harmonics to be generated in power transformers which may lead to gradual failure of power transformers conducting GIC. Two distinct methods of measuring power were used to measure reactive power consumed by the transformers under DC injection. The conventional method and the General Power Theory were used and the results show that the conventional method of measuring power underestimates reactive power consumed by transformers under the influence of DC injections. It may mislead system planners in calculating the reactive power reserves required to mitigate the effects of GIC on the power system. 2021-09-14T18:39:45Z 2021-09-14T18:39:45Z 2021_ 2021-09-14T08:07:48Z Master Thesis Masters MSc http://hdl.handle.net/11427/33892 eng application/pdf Faculty of Engineering and the Built Environment Department of Electrical Engineering
collection NDLTD
language English
format Dissertation
sources NDLTD
topic Engineering
spellingShingle Engineering
Murwira, Talent Tafadzwa
Three-phase five limb transformer responses to geomagnetically induced currents
description Geomagnetically induced currents (GIC) are quasi-DC currents that result from space weather events arising from the sun. The sun ejects hot plasma in a concept termed ‘coronal mass ejections' which is directed towards the earth. This plasma interferes with the magnetic field of the magnetosphere and ionosphere, and the magnetic field is subsequently distorted. The distortions in these regions results in the variation of potential on the earth's surface and distortions in the earth's magnetic field. The potential difference between two points on the earth's surface leads to the flow of direct current (DC) of very low frequency in the range 0.001 ~ 0.1 Hz. Geomagnetically induced currents enter into the power system through grounded neutrals of power transformers. The potential effects of GIC on transformers are asymmetrical saturation, increased harmonics, noise, magnetization current, hot spot temperature rise and reactive power consumption. Transformer responses to GIC was investigated in this research focussing on a three-phase fivelimb (3p5L) transformer. Practical tests and simulations were conducted on 15 kVA, 380/380 V, and 3p5L transformers. The results were extended to large power transformers in FEM using equivalent circuit parameters to show the response of grid-level transformers. A review of literature on the thresholds of GIC that can initiate damage in power transformers was also done and it was noted that small magnitudes of DC may cause saturation and harmonics to be generated in power transformers which may lead to gradual failure of power transformers conducting GIC. Two distinct methods of measuring power were used to measure reactive power consumed by the transformers under DC injection. The conventional method and the General Power Theory were used and the results show that the conventional method of measuring power underestimates reactive power consumed by transformers under the influence of DC injections. It may mislead system planners in calculating the reactive power reserves required to mitigate the effects of GIC on the power system.
author2 Oyedokun, David
author_facet Oyedokun, David
Murwira, Talent Tafadzwa
author Murwira, Talent Tafadzwa
author_sort Murwira, Talent Tafadzwa
title Three-phase five limb transformer responses to geomagnetically induced currents
title_short Three-phase five limb transformer responses to geomagnetically induced currents
title_full Three-phase five limb transformer responses to geomagnetically induced currents
title_fullStr Three-phase five limb transformer responses to geomagnetically induced currents
title_full_unstemmed Three-phase five limb transformer responses to geomagnetically induced currents
title_sort three-phase five limb transformer responses to geomagnetically induced currents
publisher Faculty of Engineering and the Built Environment
publishDate 2021
url http://hdl.handle.net/11427/33892
work_keys_str_mv AT murwiratalenttafadzwa threephasefivelimbtransformerresponsestogeomagneticallyinducedcurrents
_version_ 1719480924889939968