The profitability of green retrofitting the building envelope of commercial buildings in Cape Town
A notion exists that the operational savings stemming from Deep Energy Retrofits are not sufficient to justify its capital outlay. This notion has focused property developers' attention on the construction of new green buildings, rather than optimizing existing building stock. Producing new bui...
Main Author: | |
---|---|
Other Authors: | |
Format: | Dissertation |
Language: | English |
Published: |
University of Cape Town
2018
|
Subjects: | |
Online Access: | http://hdl.handle.net/11427/27428 |
id |
ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-27428 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-274282020-12-10T05:11:02Z The profitability of green retrofitting the building envelope of commercial buildings in Cape Town Botha, Jaco Le Jeune, Karen Property Studies A notion exists that the operational savings stemming from Deep Energy Retrofits are not sufficient to justify its capital outlay. This notion has focused property developers' attention on the construction of new green buildings, rather than optimizing existing building stock. Producing new buildings, while many existing properties are utilized on a sub-optimal level, with low rental income and high vacancies is not only resource inefficient, but also contributes to a much greater carbon footprint. The aim of this research is to establish whether retrofitting is a viable means of optimizing energy consumption in buildings based on investment return. The literature reveals that the façade is the most significant variable in energy optimisation in buildings and concluded that over-cladding strategies are generally the most efficient means to reduce heat transfer and control lighting levels. The research have been conducted by means of a two tiered methodology involving a case study approach, along with an experimental design, which was conducted through a simulation. A hypothetical building, representative of Cape Town's building stock was modeled and a number of façade over-clad strategies simulated to derive the most optimal solution. The simulation is conducted in DOE Energy Plus and COMFEN GUI. Capital cost data was collected and compared to energy cost savings in order to determine payback values. It was found that over-clad strategies may be economically feasible, which delivered payback periods of between 5 and 19 years, depending on the strategy. A partial retrofit, involving only the East and West facades was found to be the most feasible from an investment point of view, where woven mesh screens delivered the best results. 2018-02-09T07:09:17Z 2018-02-09T07:09:17Z 2017 Master Thesis Masters MSc http://hdl.handle.net/11427/27428 eng application/pdf University of Cape Town Faculty of Engineering and the Built Environment Department of Construction Economics and Management |
collection |
NDLTD |
language |
English |
format |
Dissertation |
sources |
NDLTD |
topic |
Property Studies |
spellingShingle |
Property Studies Botha, Jaco The profitability of green retrofitting the building envelope of commercial buildings in Cape Town |
description |
A notion exists that the operational savings stemming from Deep Energy Retrofits are not sufficient to justify its capital outlay. This notion has focused property developers' attention on the construction of new green buildings, rather than optimizing existing building stock. Producing new buildings, while many existing properties are utilized on a sub-optimal level, with low rental income and high vacancies is not only resource inefficient, but also contributes to a much greater carbon footprint. The aim of this research is to establish whether retrofitting is a viable means of optimizing energy consumption in buildings based on investment return. The literature reveals that the façade is the most significant variable in energy optimisation in buildings and concluded that over-cladding strategies are generally the most efficient means to reduce heat transfer and control lighting levels. The research have been conducted by means of a two tiered methodology involving a case study approach, along with an experimental design, which was conducted through a simulation. A hypothetical building, representative of Cape Town's building stock was modeled and a number of façade over-clad strategies simulated to derive the most optimal solution. The simulation is conducted in DOE Energy Plus and COMFEN GUI. Capital cost data was collected and compared to energy cost savings in order to determine payback values. It was found that over-clad strategies may be economically feasible, which delivered payback periods of between 5 and 19 years, depending on the strategy. A partial retrofit, involving only the East and West facades was found to be the most feasible from an investment point of view, where woven mesh screens delivered the best results. |
author2 |
Le Jeune, Karen |
author_facet |
Le Jeune, Karen Botha, Jaco |
author |
Botha, Jaco |
author_sort |
Botha, Jaco |
title |
The profitability of green retrofitting the building envelope of commercial buildings in Cape Town |
title_short |
The profitability of green retrofitting the building envelope of commercial buildings in Cape Town |
title_full |
The profitability of green retrofitting the building envelope of commercial buildings in Cape Town |
title_fullStr |
The profitability of green retrofitting the building envelope of commercial buildings in Cape Town |
title_full_unstemmed |
The profitability of green retrofitting the building envelope of commercial buildings in Cape Town |
title_sort |
profitability of green retrofitting the building envelope of commercial buildings in cape town |
publisher |
University of Cape Town |
publishDate |
2018 |
url |
http://hdl.handle.net/11427/27428 |
work_keys_str_mv |
AT bothajaco theprofitabilityofgreenretrofittingthebuildingenvelopeofcommercialbuildingsincapetown AT bothajaco profitabilityofgreenretrofittingthebuildingenvelopeofcommercialbuildingsincapetown |
_version_ |
1719369265665015808 |