The in-service non-destructive evaluation of wooden transmission line poles

This thesis covers the research undertaken on behalf of the ESKOM TRI Group into the In-service Non-Destructive Evaluation of Wooden Transmission Line Poles. The aim of this work was the development of an effective pole tester that could be used to test the integrity of wooden transmission line pole...

Full description

Bibliographic Details
Main Author: Prestage, Brendan Paul
Other Authors: Gryzagoridis, Jasson
Format: Dissertation
Language:English
Published: University of Cape Town 2016
Subjects:
Online Access:http://hdl.handle.net/11427/21340
id ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-21340
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-213402020-12-10T05:11:07Z The in-service non-destructive evaluation of wooden transmission line poles Prestage, Brendan Paul Gryzagoridis, Jasson Mechanical Engineering This thesis covers the research undertaken on behalf of the ESKOM TRI Group into the In-service Non-Destructive Evaluation of Wooden Transmission Line Poles. The aim of this work was the development of an effective pole tester that could be used to test the integrity of wooden transmission line poles in situ. The pole testing method that ESKOM uses at present is both time and labour intensive and it is envisaged that this research will contribute to the establishment of a faster, cheaper and more effective alternative. The research began with a literature survey of past investigations. Previous research in this area followed two distinct approaches. The first approach concentrated on mechanical testing procedures. For example the physical bending of the pole and measuring its bending stress (the effect that this bending has on the single fibres in the pole is not documented). The present ESKOM pole tester follows this approach. The second approach has been in the field of true "non-destructive" testing. Procedures using x-rays, magnetic resonance imaging and vibration analysis have all been considered in the past by investigators. The present investigation followed the approach of vibrations analysis. The process involved impacting the pole and measuring its vibration response. The response was then used to analyse the pole's behaviour. The state of integrity of the pole determined its vibration characteristics. 2016-08-18T13:55:00Z 2016-08-18T13:55:00Z 1998 Master Thesis Masters MSc (Eng) http://hdl.handle.net/11427/21340 eng application/pdf University of Cape Town Faculty of Engineering and the Built Environment Department of Mechanical Engineering
collection NDLTD
language English
format Dissertation
sources NDLTD
topic Mechanical Engineering
spellingShingle Mechanical Engineering
Prestage, Brendan Paul
The in-service non-destructive evaluation of wooden transmission line poles
description This thesis covers the research undertaken on behalf of the ESKOM TRI Group into the In-service Non-Destructive Evaluation of Wooden Transmission Line Poles. The aim of this work was the development of an effective pole tester that could be used to test the integrity of wooden transmission line poles in situ. The pole testing method that ESKOM uses at present is both time and labour intensive and it is envisaged that this research will contribute to the establishment of a faster, cheaper and more effective alternative. The research began with a literature survey of past investigations. Previous research in this area followed two distinct approaches. The first approach concentrated on mechanical testing procedures. For example the physical bending of the pole and measuring its bending stress (the effect that this bending has on the single fibres in the pole is not documented). The present ESKOM pole tester follows this approach. The second approach has been in the field of true "non-destructive" testing. Procedures using x-rays, magnetic resonance imaging and vibration analysis have all been considered in the past by investigators. The present investigation followed the approach of vibrations analysis. The process involved impacting the pole and measuring its vibration response. The response was then used to analyse the pole's behaviour. The state of integrity of the pole determined its vibration characteristics.
author2 Gryzagoridis, Jasson
author_facet Gryzagoridis, Jasson
Prestage, Brendan Paul
author Prestage, Brendan Paul
author_sort Prestage, Brendan Paul
title The in-service non-destructive evaluation of wooden transmission line poles
title_short The in-service non-destructive evaluation of wooden transmission line poles
title_full The in-service non-destructive evaluation of wooden transmission line poles
title_fullStr The in-service non-destructive evaluation of wooden transmission line poles
title_full_unstemmed The in-service non-destructive evaluation of wooden transmission line poles
title_sort in-service non-destructive evaluation of wooden transmission line poles
publisher University of Cape Town
publishDate 2016
url http://hdl.handle.net/11427/21340
work_keys_str_mv AT prestagebrendanpaul theinservicenondestructiveevaluationofwoodentransmissionlinepoles
AT prestagebrendanpaul inservicenondestructiveevaluationofwoodentransmissionlinepoles
_version_ 1719369198692466688