Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital, Cape Town, South Africa

Objectives: Little is known about the performance of re - used pacemakers and implantable cardioverter defibrillators (ICDs) in Africa. We sought to compare the risk of infection and the rate of malfunction of re - used pacemakers and ICDs with new devices at Groote Schuur Hospital in Cape Town,...

Full description

Bibliographic Details
Main Author: Jama, Zimasa Vuyo
Other Authors: Mayosi, Bongani M
Format: Dissertation
Language:English
Published: University of Cape Town 2016
Subjects:
Online Access:http://hdl.handle.net/11427/20958
id ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-20958
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-uct-oai-localhost-11427-209582021-07-16T05:08:48Z Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital, Cape Town, South Africa Jama, Zimasa Vuyo Mayosi, Bongani M Chin, Ashley Medicine Objectives: Little is known about the performance of re - used pacemakers and implantable cardioverter defibrillators (ICDs) in Africa. We sought to compare the risk of infection and the rate of malfunction of re - used pacemakers and ICDs with new devices at Groote Schuur Hospital in Cape Town, South Africa. Methods: This was a retrospective case comparison study of performance of re - used pacemakers and ICDs in comparison with new devices at Groote Schuur hospital over a 10 year period. The outcomes were incidence of device infection, device malfunction, early battery depletion, and device removal due to infection, malfunction, or early battery depletion. Results: Data for 126 devices implanted in 126 patients between 2003 and 2013 were analysed, of which 102 (81%) were pacemakers (51 re - used and 51 new) and 24 (19%) were ICDs (12 re - used and 12 new). There was no device infection, malfunction, early battery depletion or device removal in either the re - used or new pacemaker groups ov er the median follow up of 15.1 months (interquartile range (IQR), 1.3 - 36.24 months) for re - used pacemakers and 55.8 months (IQR, 20.3 - 77.8 months) for new pacemakers. In the ICD group, no device infection occurred over a median follow up of 35.9 months (I QR, 17.0 - 70.9 months) for re - used ICDs and 45.7 months (IQR, 37.6 - 53.7 months) for new ICDs. One device delivered inappropriate shocks which resolved without intervention and no harm to the patient, this re - used ICD subsequently needed generator replacement 14 months later. In both, the pacemaker and ICD groups, there were no procedure non related infections documented for the respective follow up periods. Conclusion: No significant differences were found in performance between re - used and new pacemakers and ICDs with respect to infection rates, device malfunction, and battery life and device removal for complications. Pacemaker and ICD reusee is feasible and safe and is a viable option for patients with bradyarrhythmias and tachyarrthythmias. 2016-07-28T12:20:33Z 2016-07-28T12:20:33Z 2016 Master Thesis Masters MMed http://hdl.handle.net/11427/20958 eng application/pdf University of Cape Town Faculty of Health Sciences Department of Medicine
collection NDLTD
language English
format Dissertation
sources NDLTD
topic Medicine
spellingShingle Medicine
Jama, Zimasa Vuyo
Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital, Cape Town, South Africa
description Objectives: Little is known about the performance of re - used pacemakers and implantable cardioverter defibrillators (ICDs) in Africa. We sought to compare the risk of infection and the rate of malfunction of re - used pacemakers and ICDs with new devices at Groote Schuur Hospital in Cape Town, South Africa. Methods: This was a retrospective case comparison study of performance of re - used pacemakers and ICDs in comparison with new devices at Groote Schuur hospital over a 10 year period. The outcomes were incidence of device infection, device malfunction, early battery depletion, and device removal due to infection, malfunction, or early battery depletion. Results: Data for 126 devices implanted in 126 patients between 2003 and 2013 were analysed, of which 102 (81%) were pacemakers (51 re - used and 51 new) and 24 (19%) were ICDs (12 re - used and 12 new). There was no device infection, malfunction, early battery depletion or device removal in either the re - used or new pacemaker groups ov er the median follow up of 15.1 months (interquartile range (IQR), 1.3 - 36.24 months) for re - used pacemakers and 55.8 months (IQR, 20.3 - 77.8 months) for new pacemakers. In the ICD group, no device infection occurred over a median follow up of 35.9 months (I QR, 17.0 - 70.9 months) for re - used ICDs and 45.7 months (IQR, 37.6 - 53.7 months) for new ICDs. One device delivered inappropriate shocks which resolved without intervention and no harm to the patient, this re - used ICD subsequently needed generator replacement 14 months later. In both, the pacemaker and ICD groups, there were no procedure non related infections documented for the respective follow up periods. Conclusion: No significant differences were found in performance between re - used and new pacemakers and ICDs with respect to infection rates, device malfunction, and battery life and device removal for complications. Pacemaker and ICD reusee is feasible and safe and is a viable option for patients with bradyarrhythmias and tachyarrthythmias.
author2 Mayosi, Bongani M
author_facet Mayosi, Bongani M
Jama, Zimasa Vuyo
author Jama, Zimasa Vuyo
author_sort Jama, Zimasa Vuyo
title Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital, Cape Town, South Africa
title_short Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital, Cape Town, South Africa
title_full Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital, Cape Town, South Africa
title_fullStr Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital, Cape Town, South Africa
title_full_unstemmed Performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at Groote Schuur Hospital, Cape Town, South Africa
title_sort performance of re-used pacemakers and implantable cardioverter defibrillators compared with new devices at groote schuur hospital, cape town, south africa
publisher University of Cape Town
publishDate 2016
url http://hdl.handle.net/11427/20958
work_keys_str_mv AT jamazimasavuyo performanceofreusedpacemakersandimplantablecardioverterdefibrillatorscomparedwithnewdevicesatgrooteschuurhospitalcapetownsouthafrica
_version_ 1719417063122927616