Development of a digital X-ray-imaging system at the National Accelerator Centre

Thesis (MSc)--Stellenbosch University, 2000. === ENGLISH ABSTRACT: A digital portal X-ray imaging system was developed to replace the radiographic X-ray films currently used for patient position verification at the National Accelerator Centre (NAC) proton therapy facility. The main advantage of a...

Full description

Bibliographic Details
Main Author: Latti, Emari (Emarencia Martha)
Other Authors: Stander, J. A.
Format: Others
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2012
Subjects:
Online Access:http://hdl.handle.net/10019.1/51685
id ndltd-netd.ac.za-oai-union.ndltd.org-sun-oai-scholar.sun.ac.za-10019.1-51685
record_format oai_dc
collection NDLTD
language en_ZA
format Others
sources NDLTD
topic Imaging systems in medicine
Imaging systems
X-rays -- Equipment and supplies
Image processing -- Digital techniques
Dissertations -- Physics
spellingShingle Imaging systems in medicine
Imaging systems
X-rays -- Equipment and supplies
Image processing -- Digital techniques
Dissertations -- Physics
Latti, Emari (Emarencia Martha)
Development of a digital X-ray-imaging system at the National Accelerator Centre
description Thesis (MSc)--Stellenbosch University, 2000. === ENGLISH ABSTRACT: A digital portal X-ray imaging system was developed to replace the radiographic X-ray films currently used for patient position verification at the National Accelerator Centre (NAC) proton therapy facility. The main advantage of a digital system is the short time in which the image can be obtained. Other advantages include optimisation of the image display, effective archiving of the digital images, access from various locations through data networks, and lower operational costs. The digital system described in this thesis consists of a Gd202S:Tb scintillator screen for converting X-rays to visible light, a protected aluminum front silvered mirror to direct the light to a Charge Coupled Device (CCD) camera for capture and a personal computer for data acquisition, processing and display. Compared with other digital imaging systems, this is a simple, compact and affordable system. The properties of the various components were investigated. The Rarex G-130 (Gd202S:Tb) scintillation screen was chosen for its good spatial resolution, high emission efficiency and good matching between the spectral emission wavelength peak and the quantum efficiency of the CCD camera. The spatial resolution measured for the system with a field of view (FOV) of 290 x 190 mnr' is 1.3 lp/mm, which can be improved by increasing the CCD chip resolution or decreasing the field of view, since the CCD camera limits the spatial resolution. Intrinsic detector noise determines the lower limit of the dynamic range of the detector and is reduced by cooling the CCD camera. A dark current exposure is subtracted from the image to remove the bias signal and background signal level mainly caused by thermal noise. Photon noise, beam in-homogeneity and efficiency variations across the CCD chip are removed by a flat field correction. The digital images obtained with this system compare very well with the currently used radiographic film images and they are satisfactory for the purpose of patient position verification. Using the digital system it is possible to reduce the patient dose by 19 % and still obtain satisfactory image quality. === AFRIKAANSE OPSOMMING: 'n Digitale X-straalafbeeldingstelsel is ontwikkel om die radiografiese X-straalfilm wat tans gebruik word vir die kontrolering van die pasientposisionering voor die toediening van protonterapie by die Nasionale Versnellersentrum, te vervang. Die voordeel van die digitale sisteem is dat die beelde feitlik onmiddellik beskikbaar is. Verdere voordele sluit die optimisering van die vertoon van beeldkontras, effektiewe liassering, vinnige bereik deur datanetwerke en lae lopende kostes in. Die digitale sisteem beskryf in die tesis bestaan uit 'n gadolinium oksi-sulfied (Gd202S:Tb) sintillasieskerm wat X-strale omskakel na sigbare lig, 'n eerste-oppervlak aluminiumspieël wat die lig na 'n digitale kamera (CCD kamera) weerkaats en In persoonlike rekenaar vir dataverwerwing, verwerking en vertoon. Vergeleke met ander digitale stelsels is hierdie digitale beeldingstelsel eenvoudig, kompak en bekostigbaar. Die eienskappe van die verskillende komponente van die stelsel is ondersoek. Die Rarex G- 130 (Gd202S:Tb) sintillasieskerm IS gekies vanweë goeie resolusie, hoë emissiedoeltreffendheid en die hoë omsettingsdoeltreffendheid van die digitale kamera by die spektrale emissiegolflengte van dié sintillasieskerm. Die ruimtelike oplosvermoë van die stelsel is bepaal met In veldgrootte van 290 x 190 mnr' as 1.3 lynpare per millimeter. Die ruimtelike oplosvermoë kan verhoog word deur die kameraresolusie te verhoog of die veldgrootte te verklein, omdat die resolusie van die kamera tans die oplosvermoë van die stelsel beperk. Intrinsieke ruis van die detektor beperk die onderste grens van die dinamiese reikwydte van die detektor en kan verminder word deur die kamera te verkoel. 'n Donkerstroom-beeld word van die X-straalbeelde afgetrek om die voorspanningsein en die agtergrondsein, wat hoofsaaklik veroorsaak word deur termiese ruis, te verwyder. Ruis wat ontstaan as gevolg van fluktuasies in die aantal fotone, nie-homogeniteite in die bundel of variasie van die sensitiwiteit in die skerm word verwyder met behulp van 'n plat vlak beeld. Die digitale beelde verkry met die stelsel vergelyk goed met die beelde wat tans op film geneem word en die beeldkwalitiet is voldoende vir die kontrolering van die pasientopstelling. Dit is moontlik om die pasiëntdosis met 19 % te verminder en steeds voldoende beeldkwaliteit te verkry.
author2 Stander, J. A.
author_facet Stander, J. A.
Latti, Emari (Emarencia Martha)
author Latti, Emari (Emarencia Martha)
author_sort Latti, Emari (Emarencia Martha)
title Development of a digital X-ray-imaging system at the National Accelerator Centre
title_short Development of a digital X-ray-imaging system at the National Accelerator Centre
title_full Development of a digital X-ray-imaging system at the National Accelerator Centre
title_fullStr Development of a digital X-ray-imaging system at the National Accelerator Centre
title_full_unstemmed Development of a digital X-ray-imaging system at the National Accelerator Centre
title_sort development of a digital x-ray-imaging system at the national accelerator centre
publisher Stellenbosch : Stellenbosch University
publishDate 2012
url http://hdl.handle.net/10019.1/51685
work_keys_str_mv AT lattiemariemarenciamartha developmentofadigitalxrayimagingsystematthenationalacceleratorcentre
_version_ 1718165280064012288
spelling ndltd-netd.ac.za-oai-union.ndltd.org-sun-oai-scholar.sun.ac.za-10019.1-516852016-01-29T04:03:41Z Development of a digital X-ray-imaging system at the National Accelerator Centre Latti, Emari (Emarencia Martha) Stander, J. A. Schreuder, A. N. Stellenbosch University. Faculty of Science. Dept. of Physics. Imaging systems in medicine Imaging systems X-rays -- Equipment and supplies Image processing -- Digital techniques Dissertations -- Physics Thesis (MSc)--Stellenbosch University, 2000. ENGLISH ABSTRACT: A digital portal X-ray imaging system was developed to replace the radiographic X-ray films currently used for patient position verification at the National Accelerator Centre (NAC) proton therapy facility. The main advantage of a digital system is the short time in which the image can be obtained. Other advantages include optimisation of the image display, effective archiving of the digital images, access from various locations through data networks, and lower operational costs. The digital system described in this thesis consists of a Gd202S:Tb scintillator screen for converting X-rays to visible light, a protected aluminum front silvered mirror to direct the light to a Charge Coupled Device (CCD) camera for capture and a personal computer for data acquisition, processing and display. Compared with other digital imaging systems, this is a simple, compact and affordable system. The properties of the various components were investigated. The Rarex G-130 (Gd202S:Tb) scintillation screen was chosen for its good spatial resolution, high emission efficiency and good matching between the spectral emission wavelength peak and the quantum efficiency of the CCD camera. The spatial resolution measured for the system with a field of view (FOV) of 290 x 190 mnr' is 1.3 lp/mm, which can be improved by increasing the CCD chip resolution or decreasing the field of view, since the CCD camera limits the spatial resolution. Intrinsic detector noise determines the lower limit of the dynamic range of the detector and is reduced by cooling the CCD camera. A dark current exposure is subtracted from the image to remove the bias signal and background signal level mainly caused by thermal noise. Photon noise, beam in-homogeneity and efficiency variations across the CCD chip are removed by a flat field correction. The digital images obtained with this system compare very well with the currently used radiographic film images and they are satisfactory for the purpose of patient position verification. Using the digital system it is possible to reduce the patient dose by 19 % and still obtain satisfactory image quality. AFRIKAANSE OPSOMMING: 'n Digitale X-straalafbeeldingstelsel is ontwikkel om die radiografiese X-straalfilm wat tans gebruik word vir die kontrolering van die pasientposisionering voor die toediening van protonterapie by die Nasionale Versnellersentrum, te vervang. Die voordeel van die digitale sisteem is dat die beelde feitlik onmiddellik beskikbaar is. Verdere voordele sluit die optimisering van die vertoon van beeldkontras, effektiewe liassering, vinnige bereik deur datanetwerke en lae lopende kostes in. Die digitale sisteem beskryf in die tesis bestaan uit 'n gadolinium oksi-sulfied (Gd202S:Tb) sintillasieskerm wat X-strale omskakel na sigbare lig, 'n eerste-oppervlak aluminiumspieël wat die lig na 'n digitale kamera (CCD kamera) weerkaats en In persoonlike rekenaar vir dataverwerwing, verwerking en vertoon. Vergeleke met ander digitale stelsels is hierdie digitale beeldingstelsel eenvoudig, kompak en bekostigbaar. Die eienskappe van die verskillende komponente van die stelsel is ondersoek. Die Rarex G- 130 (Gd202S:Tb) sintillasieskerm IS gekies vanweë goeie resolusie, hoë emissiedoeltreffendheid en die hoë omsettingsdoeltreffendheid van die digitale kamera by die spektrale emissiegolflengte van dié sintillasieskerm. Die ruimtelike oplosvermoë van die stelsel is bepaal met In veldgrootte van 290 x 190 mnr' as 1.3 lynpare per millimeter. Die ruimtelike oplosvermoë kan verhoog word deur die kameraresolusie te verhoog of die veldgrootte te verklein, omdat die resolusie van die kamera tans die oplosvermoë van die stelsel beperk. Intrinsieke ruis van die detektor beperk die onderste grens van die dinamiese reikwydte van die detektor en kan verminder word deur die kamera te verkoel. 'n Donkerstroom-beeld word van die X-straalbeelde afgetrek om die voorspanningsein en die agtergrondsein, wat hoofsaaklik veroorsaak word deur termiese ruis, te verwyder. Ruis wat ontstaan as gevolg van fluktuasies in die aantal fotone, nie-homogeniteite in die bundel of variasie van die sensitiwiteit in die skerm word verwyder met behulp van 'n plat vlak beeld. Die digitale beelde verkry met die stelsel vergelyk goed met die beelde wat tans op film geneem word en die beeldkwalitiet is voldoende vir die kontrolering van die pasientopstelling. Dit is moontlik om die pasiëntdosis met 19 % te verminder en steeds voldoende beeldkwaliteit te verkry. 2012-08-27T11:34:38Z 2012-08-27T11:34:38Z 2000-12 Thesis http://hdl.handle.net/10019.1/51685 en_ZA Stellenbosch University 91 p. ; ill. Stellenbosch : Stellenbosch University