The construction of a precision conductance bridge and its application to a study of chromium sulphate complexes
A constant temperature room employing the comparatively new method of temperature control by means of a thyratron relay has been constructed. A high precision conductance bridge has been built in a very convenient form. Improvements include the incorporation of a cathode ray oscilloscope as null det...
Main Author: | |
---|---|
Format: | Others |
Language: | English |
Published: |
Rhodes University
1949
|
Subjects: | |
Online Access: | http://hdl.handle.net/10962/d1012038 |
id |
ndltd-netd.ac.za-oai-union.ndltd.org-rhodes-vital-4476 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-netd.ac.za-oai-union.ndltd.org-rhodes-vital-44762017-09-14T04:16:33ZThe construction of a precision conductance bridge and its application to a study of chromium sulphate complexesGoddard, Errol DesmondChromiumA constant temperature room employing the comparatively new method of temperature control by means of a thyratron relay has been constructed. A high precision conductance bridge has been built in a very convenient form. Improvements include the incorporation of a cathode ray oscilloscope as null detector and the inclusion of a very stable oscillator of the phase shift type which is capable of giving a very pure wave form. Tests carried out on a system of degenerative tuning showed the the system is not easily applicable to high gain amplifiers. A new form of conductometric titration cell, employing the dipping type electrodes has been designed with special precautions against possible Parker Effect. A series of tests has been carried out on three types of cell to ascertain the effects of absorption, polarisation and Parker Effect on the accuracy of an ordinary conductometric titration. Conductometric titrations of NaOH solutions of violet and green chromic sulphate has been carried out, and the effect of aging these solutions closely studied. In addition, conductometric titrations of BaCL₂ into the chromic solutions have been made, and the NaOH titrations have been studied potentiometrically as well.Rhodes UniversityFaculty of Science, Chemistry1949ThesisMastersMSc158 p.pdfpdfvital:4476http://hdl.handle.net/10962/d1012038EnglishAll degree certificates issued during the period 1904-1950 were issued by the University of the Cape of Good Hope/University of South Africa. Unisa owns the copyright of all Rhodes theses up to 1950. |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Chromium |
spellingShingle |
Chromium Goddard, Errol Desmond The construction of a precision conductance bridge and its application to a study of chromium sulphate complexes |
description |
A constant temperature room employing the comparatively new method of temperature control by means of a thyratron relay has been constructed. A high precision conductance bridge has been built in a very convenient form. Improvements include the incorporation of a cathode ray oscilloscope as null detector and the inclusion of a very stable oscillator of the phase shift type which is capable of giving a very pure wave form. Tests carried out on a system of degenerative tuning showed the the system is not easily applicable to high gain amplifiers. A new form of conductometric titration cell, employing the dipping type electrodes has been designed with special precautions against possible Parker Effect. A series of tests has been carried out on three types of cell to ascertain the effects of absorption, polarisation and Parker Effect on the accuracy of an ordinary conductometric titration. Conductometric titrations of NaOH solutions of violet and green chromic sulphate has been carried out, and the effect of aging these solutions closely studied. In addition, conductometric titrations of BaCL₂ into the chromic solutions have been made, and the NaOH titrations have been studied potentiometrically as well. |
author |
Goddard, Errol Desmond |
author_facet |
Goddard, Errol Desmond |
author_sort |
Goddard, Errol Desmond |
title |
The construction of a precision conductance bridge and its application to a study of chromium sulphate complexes |
title_short |
The construction of a precision conductance bridge and its application to a study of chromium sulphate complexes |
title_full |
The construction of a precision conductance bridge and its application to a study of chromium sulphate complexes |
title_fullStr |
The construction of a precision conductance bridge and its application to a study of chromium sulphate complexes |
title_full_unstemmed |
The construction of a precision conductance bridge and its application to a study of chromium sulphate complexes |
title_sort |
construction of a precision conductance bridge and its application to a study of chromium sulphate complexes |
publisher |
Rhodes University |
publishDate |
1949 |
url |
http://hdl.handle.net/10962/d1012038 |
work_keys_str_mv |
AT goddarderroldesmond theconstructionofaprecisionconductancebridgeanditsapplicationtoastudyofchromiumsulphatecomplexes AT goddarderroldesmond constructionofaprecisionconductancebridgeanditsapplicationtoastudyofchromiumsulphatecomplexes |
_version_ |
1718532676993941504 |