Development of a low imaging signature cervical spine disc arthroplasty / Neville Jansen

Spinal disc replacements have the fundamental goal of pain relief while prolonging lifespan of adjacent intervertebral discs. This study focuses on reducing magnetic resonance (MR) artefacts, thereby improving the post–operative imaging qualities of the Kineflex cervical disc arthroplasty. Magnetic...

Full description

Bibliographic Details
Main Author: Jansen, Neville
Published: North-West University 2011
Online Access:http://hdl.handle.net/10394/4843
id ndltd-netd.ac.za-oai-union.ndltd.org-nwu-oai-dspace.nwu.ac.za-10394-4843
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-nwu-oai-dspace.nwu.ac.za-10394-48432014-04-16T03:53:08ZDevelopment of a low imaging signature cervical spine disc arthroplasty / Neville JansenJansen, NevilleSpinal disc replacements have the fundamental goal of pain relief while prolonging lifespan of adjacent intervertebral discs. This study focuses on reducing magnetic resonance (MR) artefacts, thereby improving the post–operative imaging qualities of the Kineflex cervical disc arthroplasty. Magnetic resonance imaging (MRI) is used to evaluate the success of the resulting design, as it provides the greatest distinction between various cellular types, and is the technique of choice for spinal diagnosis. Initial research includes a survey of the most recent findings regarding cervical kinematics, the pathology of degenerative disc disease, treatments of cervical myelopathy and radiculopathy, and the complications associated with total disc replacement. The influence of modern imaging techniques and the properties of common biomaterials are investigated to obtain the basis for development Reducing the occurrence of MR artefacts is achieved through material selection and design adaptation. Various biomaterials used in spinal applications are evaluated for their clinical performance. Smaller artifacts are achieved by replacement of cobalt–chromium–molybdenum (CCM) of the original device, with a combination of polyether–ether–ketone (PEEK) and titanium due to a lower magnetic susceptibility Testing of the device is performed in two phases: verification and validation. The prototype device is successfully verified by means of MR, computed tomography (CT) and fluoroscopy imaging of a human cadaver spine with the device in the C5–6 position. Successful verification of the prototype warranted further development. After reviewing manufacturing techniques, validation is achieved on a production–ready device to characterise the MR signature of the end product. Artefact area is reduced from 1842mm² to 242mm², allowing for visibility of both spinal nerve roots and adjacent intervertebral discs. The spinal canal remains affected by encroachment of artefacts by 2–3mm, but the improvement in imaging signature over the existing CCM device is significant. The resulting Kineflex product is expected to find considerable application in industry.Thesis (M.Ing. (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2011.North-West University2011-10-03T07:58:59Z2011-10-03T07:58:59Z2010Thesishttp://hdl.handle.net/10394/4843
collection NDLTD
sources NDLTD
description Spinal disc replacements have the fundamental goal of pain relief while prolonging lifespan of adjacent intervertebral discs. This study focuses on reducing magnetic resonance (MR) artefacts, thereby improving the post–operative imaging qualities of the Kineflex cervical disc arthroplasty. Magnetic resonance imaging (MRI) is used to evaluate the success of the resulting design, as it provides the greatest distinction between various cellular types, and is the technique of choice for spinal diagnosis. Initial research includes a survey of the most recent findings regarding cervical kinematics, the pathology of degenerative disc disease, treatments of cervical myelopathy and radiculopathy, and the complications associated with total disc replacement. The influence of modern imaging techniques and the properties of common biomaterials are investigated to obtain the basis for development Reducing the occurrence of MR artefacts is achieved through material selection and design adaptation. Various biomaterials used in spinal applications are evaluated for their clinical performance. Smaller artifacts are achieved by replacement of cobalt–chromium–molybdenum (CCM) of the original device, with a combination of polyether–ether–ketone (PEEK) and titanium due to a lower magnetic susceptibility Testing of the device is performed in two phases: verification and validation. The prototype device is successfully verified by means of MR, computed tomography (CT) and fluoroscopy imaging of a human cadaver spine with the device in the C5–6 position. Successful verification of the prototype warranted further development. After reviewing manufacturing techniques, validation is achieved on a production–ready device to characterise the MR signature of the end product. Artefact area is reduced from 1842mm² to 242mm², allowing for visibility of both spinal nerve roots and adjacent intervertebral discs. The spinal canal remains affected by encroachment of artefacts by 2–3mm, but the improvement in imaging signature over the existing CCM device is significant. The resulting Kineflex product is expected to find considerable application in industry. === Thesis (M.Ing. (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2011.
author Jansen, Neville
spellingShingle Jansen, Neville
Development of a low imaging signature cervical spine disc arthroplasty / Neville Jansen
author_facet Jansen, Neville
author_sort Jansen, Neville
title Development of a low imaging signature cervical spine disc arthroplasty / Neville Jansen
title_short Development of a low imaging signature cervical spine disc arthroplasty / Neville Jansen
title_full Development of a low imaging signature cervical spine disc arthroplasty / Neville Jansen
title_fullStr Development of a low imaging signature cervical spine disc arthroplasty / Neville Jansen
title_full_unstemmed Development of a low imaging signature cervical spine disc arthroplasty / Neville Jansen
title_sort development of a low imaging signature cervical spine disc arthroplasty / neville jansen
publisher North-West University
publishDate 2011
url http://hdl.handle.net/10394/4843
work_keys_str_mv AT jansenneville developmentofalowimagingsignaturecervicalspinediscarthroplastynevillejansen
_version_ 1716663922372640768