A novel blood glucose characterisation system for type 1 diabetes / Johan Albert van der Westhuizen
The correct administration of insulin is a constant challenge for type 1 diabetics. The correct insulin regime leads to fewer complications and an easier way of life. The amount of insulin administered must take into account the meals eaten, previous administered insulin, exercise etc. A rapid proce...
Main Author: | |
---|---|
Language: | en |
Published: |
North-West University
2011
|
Subjects: | |
Online Access: | http://hdl.handle.net/10394/4186 |
id |
ndltd-netd.ac.za-oai-union.ndltd.org-nwu-oai-dspace.nwu.ac.za-10394-4186 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-netd.ac.za-oai-union.ndltd.org-nwu-oai-dspace.nwu.ac.za-10394-41862014-04-16T03:53:06ZA novel blood glucose characterisation system for type 1 diabetes / Johan Albert van der WesthuizenVan der Westhuizen, Johan AlbertBasal insulinBlood glucose controlInsulin calculationBolus insulinEquivalent teaspoons sugarEtsGlycaemic controlInsulin regimeInsulin recommendationsType 1 diabetesGlucose characterisationThe correct administration of insulin is a constant challenge for type 1 diabetics. The correct insulin regime leads to fewer complications and an easier way of life. The amount of insulin administered must take into account the meals eaten, previous administered insulin, exercise etc. A rapid process for determining insulin regimes that is accessible to type 1 diabetics will greatly reduce diabetic complications later in life. This study researches such a process. Software is developed to use the ets-concept to simulate blood glucose levels. From these simulations blood glucose characterisation can be done to propose insulin regimes. Data gathered in previous studies is used to verify the results of this process. These results are compared to factors that describe the accuracy of a person's blood glucose control. The effects the new regimes will have are used to make recommendations to the end-user. Accurate characterisation leads to insulin regImes that will Improve the control performance of type 1 diabetes.Thesis (M.Ing. (Electronical Engineering)--North-West University, Potchefstroom Campus, 2008.North-West University2011-06-21T10:45:59Z2011-06-21T10:45:59Z2008Thesis (M.Ing. (Electronical Engineering)--North-West University, Potchefstroom Campus, 2008.http://hdl.handle.net/10394/4186en |
collection |
NDLTD |
language |
en |
sources |
NDLTD |
topic |
Basal insulin Blood glucose control Insulin calculation Bolus insulin Equivalent teaspoons sugar Ets Glycaemic control Insulin regime Insulin recommendations Type 1 diabetes Glucose characterisation |
spellingShingle |
Basal insulin Blood glucose control Insulin calculation Bolus insulin Equivalent teaspoons sugar Ets Glycaemic control Insulin regime Insulin recommendations Type 1 diabetes Glucose characterisation Van der Westhuizen, Johan Albert A novel blood glucose characterisation system for type 1 diabetes / Johan Albert van der Westhuizen |
description |
The correct administration of insulin is a constant challenge for type 1 diabetics. The
correct insulin regime leads to fewer complications and an easier way of life. The
amount of insulin administered must take into account the meals eaten, previous
administered insulin, exercise etc.
A rapid process for determining insulin regimes that is accessible to type 1 diabetics
will greatly reduce diabetic complications later in life. This study researches such a
process. Software is developed to use the ets-concept to simulate blood glucose
levels. From these simulations blood glucose characterisation can be done to propose
insulin regimes.
Data gathered in previous studies is used to verify the results of this process. These
results are compared to factors that describe the accuracy of a person's blood glucose
control. The effects the new regimes will have are used to make recommendations to
the end-user.
Accurate characterisation leads to insulin regImes that will Improve the control
performance of type 1 diabetes. === Thesis (M.Ing. (Electronical Engineering)--North-West University, Potchefstroom Campus, 2008. |
author |
Van der Westhuizen, Johan Albert |
author_facet |
Van der Westhuizen, Johan Albert |
author_sort |
Van der Westhuizen, Johan Albert |
title |
A novel blood glucose characterisation system for type 1 diabetes / Johan Albert van der Westhuizen |
title_short |
A novel blood glucose characterisation system for type 1 diabetes / Johan Albert van der Westhuizen |
title_full |
A novel blood glucose characterisation system for type 1 diabetes / Johan Albert van der Westhuizen |
title_fullStr |
A novel blood glucose characterisation system for type 1 diabetes / Johan Albert van der Westhuizen |
title_full_unstemmed |
A novel blood glucose characterisation system for type 1 diabetes / Johan Albert van der Westhuizen |
title_sort |
novel blood glucose characterisation system for type 1 diabetes / johan albert van der westhuizen |
publisher |
North-West University |
publishDate |
2011 |
url |
http://hdl.handle.net/10394/4186 |
work_keys_str_mv |
AT vanderwesthuizenjohanalbert anovelbloodglucosecharacterisationsystemfortype1diabetesjohanalbertvanderwesthuizen AT vanderwesthuizenjohanalbert novelbloodglucosecharacterisationsystemfortype1diabetesjohanalbertvanderwesthuizen |
_version_ |
1716663766423175168 |