Management model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at Medupi power station / Frederik Jacobus Fourie

According to the Department of Water Affairs (DWAF, 2004 p.15), South Africa’s water resources are scarce and extremely limited and much of this precious resource is utilised and consumed in our industries. Treatment and re-use of effluent generated is, in some cases, preferred over use of alternate...

Full description

Bibliographic Details
Main Author: Fourie, Frederik Jacobus
Language:en
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/10394/11052
id ndltd-netd.ac.za-oai-union.ndltd.org-nwu-oai-dspace.nwu.ac.za-10394-11052
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-nwu-oai-dspace.nwu.ac.za-10394-110522014-09-30T04:04:34ZManagement model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at Medupi power station / Frederik Jacobus FourieFourie, Frederik JacobusUltra-filtration (UF)Reverse osmosis (RO)MembranesBackwashingRO brineModelling toolMedupi power stationAccording to the Department of Water Affairs (DWAF, 2004 p.15), South Africa’s water resources are scarce and extremely limited and much of this precious resource is utilised and consumed in our industries. Treatment and re-use of effluent generated is, in some cases, preferred over use of alternate water resources (Du Plessis, 2008 p.3). The volume of effluent generated in treatment processes like ultra-filtration (UF) and reverse osmosis (RO) units is determined by the feed water quality, with high water loss through effluent generation at poor feed water quality. Current UF and RO applications require an increased UF production capacity due to the use of UF filtrate for periodic backwashing of the UF membrane units. This results in loss of water and decreases overall recovery. The need therefore exists to increase the overall recovery of product water from the raw water stream by reducing the amount of effluent generated. This would be possible to achieve by using RO brine to backwash the UF unit. The study was conducted to provide a modelling tool, assisting management to optimise the use of RO brine as backwash water on the UF system at the Medupi power station. The secondary objective of this study was the development of a modelling tool that can be used for other projects, new or existing, as a measure and indication of the usability of RO brine as backwash water on UF systems. By successfully applying this newly developed model, the viability of utilising the RO brine as backwash water for the UF was investigated. This modification would lead to utilizing smaller UF units than previously envisioned, which in turn leads to reducing capital cost with 11.07% and operating expenditure with 9.98% at the Medupi power station. This also has a positive environmental impact by reducing the amount of raw water used monthly by 10.34% (108 000 m3/month).MIng (Development and Management Engineering), North-West University, Potchefstroom Campus, 20142014-08-08T09:57:05Z2014-08-08T09:57:05Z2014Thesishttp://hdl.handle.net/10394/11052en
collection NDLTD
language en
sources NDLTD
topic Ultra-filtration (UF)
Reverse osmosis (RO)
Membranes
Backwashing
RO brine
Modelling tool
Medupi power station
spellingShingle Ultra-filtration (UF)
Reverse osmosis (RO)
Membranes
Backwashing
RO brine
Modelling tool
Medupi power station
Fourie, Frederik Jacobus
Management model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at Medupi power station / Frederik Jacobus Fourie
description According to the Department of Water Affairs (DWAF, 2004 p.15), South Africa’s water resources are scarce and extremely limited and much of this precious resource is utilised and consumed in our industries. Treatment and re-use of effluent generated is, in some cases, preferred over use of alternate water resources (Du Plessis, 2008 p.3). The volume of effluent generated in treatment processes like ultra-filtration (UF) and reverse osmosis (RO) units is determined by the feed water quality, with high water loss through effluent generation at poor feed water quality. Current UF and RO applications require an increased UF production capacity due to the use of UF filtrate for periodic backwashing of the UF membrane units. This results in loss of water and decreases overall recovery. The need therefore exists to increase the overall recovery of product water from the raw water stream by reducing the amount of effluent generated. This would be possible to achieve by using RO brine to backwash the UF unit. The study was conducted to provide a modelling tool, assisting management to optimise the use of RO brine as backwash water on the UF system at the Medupi power station. The secondary objective of this study was the development of a modelling tool that can be used for other projects, new or existing, as a measure and indication of the usability of RO brine as backwash water on UF systems. By successfully applying this newly developed model, the viability of utilising the RO brine as backwash water for the UF was investigated. This modification would lead to utilizing smaller UF units than previously envisioned, which in turn leads to reducing capital cost with 11.07% and operating expenditure with 9.98% at the Medupi power station. This also has a positive environmental impact by reducing the amount of raw water used monthly by 10.34% (108 000 m3/month). === MIng (Development and Management Engineering), North-West University, Potchefstroom Campus, 2014
author Fourie, Frederik Jacobus
author_facet Fourie, Frederik Jacobus
author_sort Fourie, Frederik Jacobus
title Management model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at Medupi power station / Frederik Jacobus Fourie
title_short Management model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at Medupi power station / Frederik Jacobus Fourie
title_full Management model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at Medupi power station / Frederik Jacobus Fourie
title_fullStr Management model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at Medupi power station / Frederik Jacobus Fourie
title_full_unstemmed Management model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at Medupi power station / Frederik Jacobus Fourie
title_sort management model to optimise the use of reverse osmosis brine to backwash ultra-filtration systems at medupi power station / frederik jacobus fourie
publishDate 2014
url http://hdl.handle.net/10394/11052
work_keys_str_mv AT fouriefrederikjacobus managementmodeltooptimisetheuseofreverseosmosisbrinetobackwashultrafiltrationsystemsatmedupipowerstationfrederikjacobusfourie
_version_ 1716715345415241728