Communication Through Breath Using Molecular Communication Modeling in Indoor Environments

The concept of communication via breath is introduced under the molecular com munication system, where data can be exchanged through inhalation and exhalation. Those data are carried by volatile organic compounds (VOCs) or pathogens and transferred through an aerosol channel. In this thesis, we p...

Full description

Bibliographic Details
Main Author: Almayouf, Nojood
Other Authors: Alouini, Mohamed-Slim
Language:en
Published: 2019
Subjects:
Online Access:Almayouf, N. (2019). Communication Through Breath Using Molecular Communication Modeling in Indoor Environments. KAUST Research Repository. https://doi.org/10.25781/KAUST-4SK53
http://hdl.handle.net/10754/660192
id ndltd-kaust.edu.sa-oai-repository.kaust.edu.sa-10754-660192
record_format oai_dc
spelling ndltd-kaust.edu.sa-oai-repository.kaust.edu.sa-10754-6601922021-02-20T05:10:56Z Communication Through Breath Using Molecular Communication Modeling in Indoor Environments Almayouf, Nojood Alouini, Mohamed-Slim Computer, Electrical and Mathematical Sciences and Engineering (CEMSE) Division Alouini, Mohamed-Slim Al-Naffouri, Tareq Y. Amin, Osama Dahrouj, Hayssam Molecular Communication Communication Through Breath The concept of communication via breath is introduced under the molecular com munication system, where data can be exchanged through inhalation and exhalation. Those data are carried by volatile organic compounds (VOCs) or pathogens and transferred through an aerosol channel. In this thesis, we propose a molecular com munication model for an instantaneous source in a bounded indoor environment. The walls of this environment could be reflectors and/or absorbers by adjusting the value of deposition velocity. We assume a puff source in a given location and study the per formance of a point source since it is the basic element that can be used to derive the concentration of breath, cough, and sneezing, where the concentration of continuous source can be found by integrating a point source over space and time domains. Also, we show some numerical results to visualize the performance of these mathematical models and evaluate them. As a case study, we consider a real-life scenario of detecting a virus from an exhaled breath of a person standing in an indoor bounded room with reflective and absorptive walls. We derive the spatial-temporal concentration of an exhaled virus at the molecules source and the receiver in the room. Finally, we study the probability of misdetection using a suitable bio-sensor. 2019-11-24T10:30:53Z 2019-11-24T10:30:53Z 2019-11 Thesis Almayouf, N. (2019). Communication Through Breath Using Molecular Communication Modeling in Indoor Environments. KAUST Research Repository. https://doi.org/10.25781/KAUST-4SK53 10.25781/KAUST-4SK53 http://hdl.handle.net/10754/660192 en
collection NDLTD
language en
sources NDLTD
topic Molecular Communication
Communication Through Breath
spellingShingle Molecular Communication
Communication Through Breath
Almayouf, Nojood
Communication Through Breath Using Molecular Communication Modeling in Indoor Environments
description The concept of communication via breath is introduced under the molecular com munication system, where data can be exchanged through inhalation and exhalation. Those data are carried by volatile organic compounds (VOCs) or pathogens and transferred through an aerosol channel. In this thesis, we propose a molecular com munication model for an instantaneous source in a bounded indoor environment. The walls of this environment could be reflectors and/or absorbers by adjusting the value of deposition velocity. We assume a puff source in a given location and study the per formance of a point source since it is the basic element that can be used to derive the concentration of breath, cough, and sneezing, where the concentration of continuous source can be found by integrating a point source over space and time domains. Also, we show some numerical results to visualize the performance of these mathematical models and evaluate them. As a case study, we consider a real-life scenario of detecting a virus from an exhaled breath of a person standing in an indoor bounded room with reflective and absorptive walls. We derive the spatial-temporal concentration of an exhaled virus at the molecules source and the receiver in the room. Finally, we study the probability of misdetection using a suitable bio-sensor.
author2 Alouini, Mohamed-Slim
author_facet Alouini, Mohamed-Slim
Almayouf, Nojood
author Almayouf, Nojood
author_sort Almayouf, Nojood
title Communication Through Breath Using Molecular Communication Modeling in Indoor Environments
title_short Communication Through Breath Using Molecular Communication Modeling in Indoor Environments
title_full Communication Through Breath Using Molecular Communication Modeling in Indoor Environments
title_fullStr Communication Through Breath Using Molecular Communication Modeling in Indoor Environments
title_full_unstemmed Communication Through Breath Using Molecular Communication Modeling in Indoor Environments
title_sort communication through breath using molecular communication modeling in indoor environments
publishDate 2019
url Almayouf, N. (2019). Communication Through Breath Using Molecular Communication Modeling in Indoor Environments. KAUST Research Repository. https://doi.org/10.25781/KAUST-4SK53
http://hdl.handle.net/10754/660192
work_keys_str_mv AT almayoufnojood communicationthroughbreathusingmolecularcommunicationmodelinginindoorenvironments
_version_ 1719378115652747264