Boron Removal in Seawater Reverse Osmosis System

Reverse osmosis successfully proves to remove more than 99% of solute in seawater, providing fresh water supply with satisfied quality. Due to some operational constraints, however, some trace contaminants removal, such as boron, cannot be achieved in one pass system. The stringent criterion for bor...

Full description

Bibliographic Details
Main Author: Rahmawati, Karina
Other Authors: Ghaffour, NorEddine
Language:en
Published: 2012
Online Access:Rahmawati, K. (2011). Boron Removal in Seawater Reverse Osmosis System. KAUST Research Repository. https://doi.org/10.25781/KAUST-YE08I
http://hdl.handle.net/10754/209379
id ndltd-kaust.edu.sa-oai-repository.kaust.edu.sa-10754-209379
record_format oai_dc
spelling ndltd-kaust.edu.sa-oai-repository.kaust.edu.sa-10754-2093792021-09-15T05:06:42Z Boron Removal in Seawater Reverse Osmosis System Rahmawati, Karina Ghaffour, NorEddine Physical Science and Engineering (PSE) Division Sinha, Shahnawaz Wang, Peng Reverse osmosis successfully proves to remove more than 99% of solute in seawater, providing fresh water supply with satisfied quality. Due to some operational constraints, however, some trace contaminants removal, such as boron, cannot be achieved in one pass system. The stringent criterion for boron from World Health Organization (WHO) and Saudi Arabia local standard (0.5 mg/l) is hardly fulfilled by single pass sea water reverse osmosis (SWRO) plants. Some design processes have been proposed to deal with boron removal, but they are not economically efficient due to high energy and chemical consumption. The objective of this study was to study boron removal by different reverse osmosis membranes in two pH conditions, with and without antiscalant addition. Thus, it was expected to observe the possibility of operating single pass system and necessity to operate two pass system using low energy membrane. Five membrane samples were obtained from two different manufacturers. Three types of feed water pH were used, pH 8, pH 10, and pH 10 with antiscalant addition. Experiment was conducted in parallel to compare membrane performance from two manufacturers. Filtration was run with fully recycle mode for three days. Sample of permeate and feed were taken every 12 hours, and analyzed for their boron and TDS concentration. Membrane samples were also tested for their surface charge. The results showed that boron rejection increases as the feed pH increases. This was caused by dissociation of boric acid to negatively charged borate ion and more negatively charged membrane surface at elevated pH which enhance boron rejection. This study found that single pass reverse osmosis system, with and without elevating the pH, may not be possible to be applied because of two reasons. First, permeate quality in term of boron, does not fulfill WHO and local Saudi Arabia regulations. Second, severe scaling occurs due to operation in alkaline condition, since Ca and Mg concentration are still high to cause precipitation. Using low energy membrane at pH 10 may be considered, since it gives comparable performance to ordinary brackish water membranes in term of boron and TDS rejections, but consume less energy. 2012-02-04T08:27:50Z 2012-02-04T08:27:50Z 2011-07 Thesis Rahmawati, K. (2011). Boron Removal in Seawater Reverse Osmosis System. KAUST Research Repository. https://doi.org/10.25781/KAUST-YE08I 10.25781/KAUST-YE08I http://hdl.handle.net/10754/209379 en
collection NDLTD
language en
sources NDLTD
description Reverse osmosis successfully proves to remove more than 99% of solute in seawater, providing fresh water supply with satisfied quality. Due to some operational constraints, however, some trace contaminants removal, such as boron, cannot be achieved in one pass system. The stringent criterion for boron from World Health Organization (WHO) and Saudi Arabia local standard (0.5 mg/l) is hardly fulfilled by single pass sea water reverse osmosis (SWRO) plants. Some design processes have been proposed to deal with boron removal, but they are not economically efficient due to high energy and chemical consumption. The objective of this study was to study boron removal by different reverse osmosis membranes in two pH conditions, with and without antiscalant addition. Thus, it was expected to observe the possibility of operating single pass system and necessity to operate two pass system using low energy membrane. Five membrane samples were obtained from two different manufacturers. Three types of feed water pH were used, pH 8, pH 10, and pH 10 with antiscalant addition. Experiment was conducted in parallel to compare membrane performance from two manufacturers. Filtration was run with fully recycle mode for three days. Sample of permeate and feed were taken every 12 hours, and analyzed for their boron and TDS concentration. Membrane samples were also tested for their surface charge. The results showed that boron rejection increases as the feed pH increases. This was caused by dissociation of boric acid to negatively charged borate ion and more negatively charged membrane surface at elevated pH which enhance boron rejection. This study found that single pass reverse osmosis system, with and without elevating the pH, may not be possible to be applied because of two reasons. First, permeate quality in term of boron, does not fulfill WHO and local Saudi Arabia regulations. Second, severe scaling occurs due to operation in alkaline condition, since Ca and Mg concentration are still high to cause precipitation. Using low energy membrane at pH 10 may be considered, since it gives comparable performance to ordinary brackish water membranes in term of boron and TDS rejections, but consume less energy.
author2 Ghaffour, NorEddine
author_facet Ghaffour, NorEddine
Rahmawati, Karina
author Rahmawati, Karina
spellingShingle Rahmawati, Karina
Boron Removal in Seawater Reverse Osmosis System
author_sort Rahmawati, Karina
title Boron Removal in Seawater Reverse Osmosis System
title_short Boron Removal in Seawater Reverse Osmosis System
title_full Boron Removal in Seawater Reverse Osmosis System
title_fullStr Boron Removal in Seawater Reverse Osmosis System
title_full_unstemmed Boron Removal in Seawater Reverse Osmosis System
title_sort boron removal in seawater reverse osmosis system
publishDate 2012
url Rahmawati, K. (2011). Boron Removal in Seawater Reverse Osmosis System. KAUST Research Repository. https://doi.org/10.25781/KAUST-YE08I
http://hdl.handle.net/10754/209379
work_keys_str_mv AT rahmawatikarina boronremovalinseawaterreverseosmosissystem
_version_ 1719480884081459200