Mechanochemical Degradation of a Semi-Flexible Polymer

The purpose of this thesis is to detail the study of the mechanochemical degradation of a semi-flexible, highly-extended polymer, in order to create a benchmark of quantitative data for use by future investigators interested in discerning the effect of polymer conformation on the mechanochemical deg...

Full description

Bibliographic Details
Other Authors: Ostlund, Seth G. (authoraut)
Format: Others
Language:English
English
Published: Florida State University
Subjects:
Online Access:http://purl.flvc.org/fsu/fd/FSU_migr_etd-2414
id ndltd-fsu.edu-oai-fsu.digital.flvc.org-fsu_180615
record_format oai_dc
spelling ndltd-fsu.edu-oai-fsu.digital.flvc.org-fsu_1806152020-06-09T03:10:01Z Mechanochemical Degradation of a Semi-Flexible Polymer Ostlund, Seth G. (authoraut) Striegel, André M. (professor directing thesis) Dorsey, John G. (committee member) Steinbock, Oliver (committee member) Department of Chemistry and Biochemistry (degree granting department) Florida State University (degree granting institution) Text text Florida State University Florida State University English eng 1 online resource computer application/pdf The purpose of this thesis is to detail the study of the mechanochemical degradation of a semi-flexible, highly-extended polymer, in order to create a benchmark of quantitative data for use by future investigators interested in discerning the effect of polymer conformation on the mechanochemical degradation of polymers. Polymer conformation is known to vary in solution from a random coil to a highly extended or semi-flexible conformation. To date, there are not sufficient data to explain the role that polymer conformation might play in the degradation of polymer chains as a result of sufficient applied mechanical stresses. It seems plausible that the rate, extent, and, possibly, the mechanism of polymer degradation could all be related to the conformation of a polymer in solution. This thesis will describe the results of a controlled ultrasonic polymer degradation experiment on the highly extended polymer poly(ã-benzyl-L-glutamate), PBLG. It is hypothesized that ultrasonically irradiating a solution of PBLG dissolved in N,N-dimethyl acetamide (DMAc) with 0.5% lithium chloride will produce substantial polymer degradation attributed to both the relatively high molar mass and to the rather extended state of the polymer. According to accepted theory, the degradation process should occur in a non-random fashion with near mid-chain scission and should continue until reaching a threshold known as Mlim, the limiting molar mass. The conformation of the polymer was monitored over the course of ultrasonic degradation using multi-detector size-exclusion chromatography including static multi-angle light scattering, refractometric, and viscometric detection. Because of the extended nature of the polymer, a priori reasoning was that the fractal dimensions calculated from both the light scattering and viscometric data should be similar and that both should remain invariant as a function of increased degradation. The PBLG conformation data, in the form of a dimensionless size parameter, was compared to previously published data for a random coil, linear polystyrene degraded under the same experimental conditions, to illustrate and quantify the additional information obtained from the degradation of a highly extended polymer such as PBLG. A Thesis Submitted to the Department of Chemistry and Biochemistry in Partial Fulfillment of the Requirements for the Degree of Master of Science. Spring Semester, 2007. April 5, 2007. Polymer, Transient Elongational Flow, Degradation, Elongatonal Flow, Mark-Houwink, Polymer Conformation, Ultrasonic Degradation Includes bibliographical references. André M. Striegel, Professor Directing Thesis; John G. Dorsey, Committee Member; Oliver Steinbock, Committee Member. Biochemistry Biophysics Molecular biology Chemistry FSU_migr_etd-2414 http://purl.flvc.org/fsu/fd/FSU_migr_etd-2414 This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s). The copyright in theses and dissertations completed at Florida State University is held by the students who author them. http://diginole.lib.fsu.edu/islandora/object/fsu%3A180615/datastream/TN/view/Mechanochemical%20Degradation%20of%20a%20Semi-Flexible%20Polymer.jpg
collection NDLTD
language English
English
format Others
sources NDLTD
topic Biochemistry
Biophysics
Molecular biology
Chemistry
spellingShingle Biochemistry
Biophysics
Molecular biology
Chemistry
Mechanochemical Degradation of a Semi-Flexible Polymer
description The purpose of this thesis is to detail the study of the mechanochemical degradation of a semi-flexible, highly-extended polymer, in order to create a benchmark of quantitative data for use by future investigators interested in discerning the effect of polymer conformation on the mechanochemical degradation of polymers. Polymer conformation is known to vary in solution from a random coil to a highly extended or semi-flexible conformation. To date, there are not sufficient data to explain the role that polymer conformation might play in the degradation of polymer chains as a result of sufficient applied mechanical stresses. It seems plausible that the rate, extent, and, possibly, the mechanism of polymer degradation could all be related to the conformation of a polymer in solution. This thesis will describe the results of a controlled ultrasonic polymer degradation experiment on the highly extended polymer poly(ã-benzyl-L-glutamate), PBLG. It is hypothesized that ultrasonically irradiating a solution of PBLG dissolved in N,N-dimethyl acetamide (DMAc) with 0.5% lithium chloride will produce substantial polymer degradation attributed to both the relatively high molar mass and to the rather extended state of the polymer. According to accepted theory, the degradation process should occur in a non-random fashion with near mid-chain scission and should continue until reaching a threshold known as Mlim, the limiting molar mass. The conformation of the polymer was monitored over the course of ultrasonic degradation using multi-detector size-exclusion chromatography including static multi-angle light scattering, refractometric, and viscometric detection. Because of the extended nature of the polymer, a priori reasoning was that the fractal dimensions calculated from both the light scattering and viscometric data should be similar and that both should remain invariant as a function of increased degradation. The PBLG conformation data, in the form of a dimensionless size parameter, was compared to previously published data for a random coil, linear polystyrene degraded under the same experimental conditions, to illustrate and quantify the additional information obtained from the degradation of a highly extended polymer such as PBLG. === A Thesis Submitted to the Department of Chemistry and Biochemistry in Partial Fulfillment of the Requirements for the Degree of Master of Science. === Spring Semester, 2007. === April 5, 2007. === Polymer, Transient Elongational Flow, Degradation, Elongatonal Flow, Mark-Houwink, Polymer Conformation, Ultrasonic Degradation === Includes bibliographical references. === André M. Striegel, Professor Directing Thesis; John G. Dorsey, Committee Member; Oliver Steinbock, Committee Member.
author2 Ostlund, Seth G. (authoraut)
author_facet Ostlund, Seth G. (authoraut)
title Mechanochemical Degradation of a Semi-Flexible Polymer
title_short Mechanochemical Degradation of a Semi-Flexible Polymer
title_full Mechanochemical Degradation of a Semi-Flexible Polymer
title_fullStr Mechanochemical Degradation of a Semi-Flexible Polymer
title_full_unstemmed Mechanochemical Degradation of a Semi-Flexible Polymer
title_sort mechanochemical degradation of a semi-flexible polymer
publisher Florida State University
url http://purl.flvc.org/fsu/fd/FSU_migr_etd-2414
_version_ 1719318376236449792