Management Optimization of Energy Consumption Reduction for Residential Hot Water

The objective of this thesis is to create an automatic water management system capable of optimizing the usage of warm water stored in two water tanks to reduce the monthly energy consumption of the instant water heater installed in a residential house. This system is called Water Mixing System (WMS...

Full description

Bibliographic Details
Main Author: Cataldi, Francesco
Format: Others
Published: FIU Digital Commons 2016
Subjects:
Online Access:http://digitalcommons.fiu.edu/etd/2995
http://digitalcommons.fiu.edu/cgi/viewcontent.cgi?article=3985&context=etd
Description
Summary:The objective of this thesis is to create an automatic water management system capable of optimizing the usage of warm water stored in two water tanks to reduce the monthly energy consumption of the instant water heater installed in a residential house. This system is called Water Mixing System (WMS). The two heat sources considered are: PV-T system and heat rejected by the air condition system. The PV-T system is a new technology that allows transformation of the sun radiation into both electricity and warm water, increasing the efficiency of the panel compared to either a common photovoltaic panel or solar collector. The air-conditioning heat source, instead, recovers the heat rejected by the condenser to the environment by employing a heat exchanger that stores the heat collected in the water tank.