Broadband RF current detector

The problems to be solved in this thesis were 1) development of a broadband RF preamplifier to be used with non-ferrous current probes so that the amplified signal exceeds the errors due to cable pickup, no detection is needed in this application, and 2) development of a self-contained device that a...

Full description

Bibliographic Details
Main Author: Cabrera, George
Format: Others
Published: FIU Digital Commons 1994
Subjects:
Online Access:http://digitalcommons.fiu.edu/etd/1955
http://digitalcommons.fiu.edu/cgi/viewcontent.cgi?article=3163&context=etd
id ndltd-fiu.edu-oai-digitalcommons.fiu.edu-etd-3163
record_format oai_dc
spelling ndltd-fiu.edu-oai-digitalcommons.fiu.edu-etd-31632018-01-05T15:30:51Z Broadband RF current detector Cabrera, George The problems to be solved in this thesis were 1) development of a broadband RF preamplifier to be used with non-ferrous current probes so that the amplified signal exceeds the errors due to cable pickup, no detection is needed in this application, and 2) development of a self-contained device that amplifies and detects the output from a nonferrous current probe, providing a digital readout of the current. These instruments have been completed and are being tested for use by the National Institutes of Occupational Safety and Health (NIOSH). The self-contained current meter operates at frequencies up to 600 MHz, and detects currents as low as 8 mA . At these current magnitudes, the probe (pick-up coil) will output a voltage of 500μV (-53 dBm on 50Ω) which will have to be raised above 0 dBm. The final circuit uses a RF mixer as a variable attenuator in order to increase the dynamic range, two Monolithic Microwave Integrated Circuits (MMIC) for preamplification, a final broadband amplifier to raise the output compression point, a Schottky diode detector, a sample and hold circuit, and a liquid crystal digital panel meter. 1994-11-28T08:00:00Z text application/pdf http://digitalcommons.fiu.edu/etd/1955 http://digitalcommons.fiu.edu/cgi/viewcontent.cgi?article=3163&context=etd FIU Electronic Theses and Dissertations FIU Digital Commons Electrical and Computer Engineering Electronic Devices and Semiconductor Manufacturing
collection NDLTD
format Others
sources NDLTD
topic Electrical and Computer Engineering
Electronic Devices and Semiconductor Manufacturing
spellingShingle Electrical and Computer Engineering
Electronic Devices and Semiconductor Manufacturing
Cabrera, George
Broadband RF current detector
description The problems to be solved in this thesis were 1) development of a broadband RF preamplifier to be used with non-ferrous current probes so that the amplified signal exceeds the errors due to cable pickup, no detection is needed in this application, and 2) development of a self-contained device that amplifies and detects the output from a nonferrous current probe, providing a digital readout of the current. These instruments have been completed and are being tested for use by the National Institutes of Occupational Safety and Health (NIOSH). The self-contained current meter operates at frequencies up to 600 MHz, and detects currents as low as 8 mA . At these current magnitudes, the probe (pick-up coil) will output a voltage of 500μV (-53 dBm on 50Ω) which will have to be raised above 0 dBm. The final circuit uses a RF mixer as a variable attenuator in order to increase the dynamic range, two Monolithic Microwave Integrated Circuits (MMIC) for preamplification, a final broadband amplifier to raise the output compression point, a Schottky diode detector, a sample and hold circuit, and a liquid crystal digital panel meter.
author Cabrera, George
author_facet Cabrera, George
author_sort Cabrera, George
title Broadband RF current detector
title_short Broadband RF current detector
title_full Broadband RF current detector
title_fullStr Broadband RF current detector
title_full_unstemmed Broadband RF current detector
title_sort broadband rf current detector
publisher FIU Digital Commons
publishDate 1994
url http://digitalcommons.fiu.edu/etd/1955
http://digitalcommons.fiu.edu/cgi/viewcontent.cgi?article=3163&context=etd
work_keys_str_mv AT cabrerageorge broadbandrfcurrentdetector
_version_ 1718580995969515520