Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs)

The purpose of this research is to compare the surface dose outside the treatment area for different breast cancer irradiation modalities using Thermoluminescence Dosimeters (TLDs). Five different modalities are included in this study: Accuboost, Photon boost, Electron boost, Strut-Adjusted Volume I...

Full description

Bibliographic Details
Other Authors: Khanal, Suraj P.
Format: Others
Language:English
Published: Florida Atlantic University
Subjects:
Online Access:http://purl.flvc.org/fcla/dt/3362479
id ndltd-fau.edu-oai-fau.digital.flvc.org-fau_4192
record_format oai_dc
spelling ndltd-fau.edu-oai-fau.digital.flvc.org-fau_41922019-07-04T03:54:01Z Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs) Khanal, Suraj P. Text Electronic Thesis or Dissertation Florida Atlantic University English xiii, 63 p. : ill. (some col.) electronic The purpose of this research is to compare the surface dose outside the treatment area for different breast cancer irradiation modalities using Thermoluminescence Dosimeters (TLDs). Five different modalities are included in this study: Accuboost, Photon boost, Electron boost, Strut-Adjusted Volume Implant (SAVI), and Mammosite Multi-lumen (ML).Six points of interest (POI) on the breast cancer patients had been selected for the TLDs placement. Data from 25 breast cancer patients at Lynn Cancer Institute of the Boca Raton Regional Hospital were included in the study. The measured percentage ranges of the averaged doses at the six POIs for the different modalities are: Sternum 0.26% - 3.26%, Shoulder 0.33% - 2.79%, Eye 0.26% - 1.32%, Thyroid 0.20% - 2.75%, CLB 0.2% - 5.46%, Lower Abdomen 0.16% - 2.25%. Suraj Prasad Khanal. Thesis (M.S.)--Florida Atlantic University, 2013. Includes bibliography. Mode of access: World Wide Web. System requirements: Adobe Reader. Thermoluminescence--Therapeutic use Radiation dosimetry Breast--Cancer--Treatmernt Radiation--Measurement--Methodology http://purl.flvc.org/fcla/dt/3362479 860991003 3362479 FADT3362479 fau:4192 Charles E. Schmidt College of Science Department of Physics http://rightsstatements.org/vocab/InC/1.0/ https://fau.digital.flvc.org/islandora/object/fau%3A4192/datastream/TN/view/Evaluation%20of%20surface%20dose%20outside%20the%20treatment%20area%20for%20breast%20cancer%20irradiation%20modalities%20using%20thermoluminescence%20dosimeters%20%28TLDs%29.jpg
collection NDLTD
language English
format Others
sources NDLTD
topic Thermoluminescence--Therapeutic use
Radiation dosimetry
Breast--Cancer--Treatmernt
Radiation--Measurement--Methodology
spellingShingle Thermoluminescence--Therapeutic use
Radiation dosimetry
Breast--Cancer--Treatmernt
Radiation--Measurement--Methodology
Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs)
description The purpose of this research is to compare the surface dose outside the treatment area for different breast cancer irradiation modalities using Thermoluminescence Dosimeters (TLDs). Five different modalities are included in this study: Accuboost, Photon boost, Electron boost, Strut-Adjusted Volume Implant (SAVI), and Mammosite Multi-lumen (ML).Six points of interest (POI) on the breast cancer patients had been selected for the TLDs placement. Data from 25 breast cancer patients at Lynn Cancer Institute of the Boca Raton Regional Hospital were included in the study. The measured percentage ranges of the averaged doses at the six POIs for the different modalities are: Sternum 0.26% - 3.26%, Shoulder 0.33% - 2.79%, Eye 0.26% - 1.32%, Thyroid 0.20% - 2.75%, CLB 0.2% - 5.46%, Lower Abdomen 0.16% - 2.25%. === Suraj Prasad Khanal. === Thesis (M.S.)--Florida Atlantic University, 2013. === Includes bibliography. === Mode of access: World Wide Web. === System requirements: Adobe Reader.
author2 Khanal, Suraj P.
author_facet Khanal, Suraj P.
title Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs)
title_short Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs)
title_full Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs)
title_fullStr Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs)
title_full_unstemmed Evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (TLDs)
title_sort evaluation of surface dose outside the treatment area for breast cancer irradiation modalities using thermoluminescence dosimeters (tlds)
publisher Florida Atlantic University
url http://purl.flvc.org/fcla/dt/3362479
_version_ 1719219203457679360