Non-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial Disease
Peripheral arterial disease (PAD) is a major cause of morbidity and mortality in the USA with an estimated prevalence of up to 20% in those over 75 years. Vascular disease and kidney impairment frequently coexist; prevalence of moderate to severe renal dysfunction in PAD patients is estimated at 27-...
Main Author: | |
---|---|
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | https://doi.org/10.7916/D89W0NW9 |
id |
ndltd-columbia.edu-oai-academiccommons.columbia.edu-10.7916-D89W0NW9 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-columbia.edu-oai-academiccommons.columbia.edu-10.7916-D89W0NW92019-05-09T15:14:13ZNon-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial DiseaseAtanasova, Iliyana2012ThesesDiagnostic imagingBiomedical engineeringPeripheral arterial disease (PAD) is a major cause of morbidity and mortality in the USA with an estimated prevalence of up to 20% in those over 75 years. Vascular disease and kidney impairment frequently coexist; prevalence of moderate to severe renal dysfunction in PAD patients is estimated at 27-36%. Knowledge of location, severity, and extent of PAD is imperative for accurate diagnosis and treatment planning. However, all established imaging modalities that are routinely used for treatment planning are contra-indicated in kidney disease patients. Contrast-enhanced x-ray and CT angiography are unsafe due to exposure to nephrotoxic contrast material and ionizing radiation. Recently, the FDA has also warned against the use of gadolinium-enhanced MRA (Gd-MRA) due to evidence that gadolinium could trigger a life-threatening condition known as nephrogenic systemic fibrosis (NSF) in patients with moderate to severe kidney dysfunction. There is a clinical need to develop vascular imaging techniques that are safe in patients with coexisting PAD and renal insufficiency. The focus of this thesis was the development of a non-contrast alternative to Gd-MRA for imaging of peripheral vessels from renal to pedal arteries with MRI. A new imaging sequence for non-contrast visualization of the abdominal and pelvic arteries was designed, implemented, and validated in a small cohort of PAD patients against Gd-MRA. In addition, an existing fast spin-echo based technique for unenhanced imaging of the lower extremities was optimized for improved performance in a clinical setting.Englishhttps://doi.org/10.7916/D89W0NW9 |
collection |
NDLTD |
language |
English |
sources |
NDLTD |
topic |
Diagnostic imaging Biomedical engineering |
spellingShingle |
Diagnostic imaging Biomedical engineering Atanasova, Iliyana Non-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial Disease |
description |
Peripheral arterial disease (PAD) is a major cause of morbidity and mortality in the USA with an estimated prevalence of up to 20% in those over 75 years. Vascular disease and kidney impairment frequently coexist; prevalence of moderate to severe renal dysfunction in PAD patients is estimated at 27-36%. Knowledge of location, severity, and extent of PAD is imperative for accurate diagnosis and treatment planning. However, all established imaging modalities that are routinely used for treatment planning are contra-indicated in kidney disease patients. Contrast-enhanced x-ray and CT angiography are unsafe due to exposure to nephrotoxic contrast material and ionizing radiation. Recently, the FDA has also warned against the use of gadolinium-enhanced MRA (Gd-MRA) due to evidence that gadolinium could trigger a life-threatening condition known as nephrogenic systemic fibrosis (NSF) in patients with moderate to severe kidney dysfunction. There is a clinical need to develop vascular imaging techniques that are safe in patients with coexisting PAD and renal insufficiency. The focus of this thesis was the development of a non-contrast alternative to Gd-MRA for imaging of peripheral vessels from renal to pedal arteries with MRI. A new imaging sequence for non-contrast visualization of the abdominal and pelvic arteries was designed, implemented, and validated in a small cohort of PAD patients against Gd-MRA. In addition, an existing fast spin-echo based technique for unenhanced imaging of the lower extremities was optimized for improved performance in a clinical setting. |
author |
Atanasova, Iliyana |
author_facet |
Atanasova, Iliyana |
author_sort |
Atanasova, Iliyana |
title |
Non-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial Disease |
title_short |
Non-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial Disease |
title_full |
Non-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial Disease |
title_fullStr |
Non-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial Disease |
title_full_unstemmed |
Non-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial Disease |
title_sort |
non-contrast magnetic resonance angiography for evaluation of peripheral arterial disease |
publishDate |
2012 |
url |
https://doi.org/10.7916/D89W0NW9 |
work_keys_str_mv |
AT atanasovailiyana noncontrastmagneticresonanceangiographyforevaluationofperipheralarterialdisease |
_version_ |
1719045848827953152 |