Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control

The building sector has become the largest consumer of end use energy in the world, exceeding both the industry and the transportation sectors. Extensive types of energy saving techniques have been developed in the past two decades to mitigate the impact of buildings on the environment. Instead of t...

Full description

Bibliographic Details
Main Author: Zhang, Rongpeng
Format: Others
Published: Research Showcase @ CMU 2014
Subjects:
Online Access:http://repository.cmu.edu/dissertations/404
http://repository.cmu.edu/cgi/viewcontent.cgi?article=1404&context=dissertations
id ndltd-cmu.edu-oai-repository.cmu.edu-dissertations-1404
record_format oai_dc
collection NDLTD
format Others
sources NDLTD
topic building energy efficiency
building enthalpy control
integrated active-passive strategies
air conditioning and dehumidification
dynamic optimization
simultaneous collocation
spellingShingle building energy efficiency
building enthalpy control
integrated active-passive strategies
air conditioning and dehumidification
dynamic optimization
simultaneous collocation
Zhang, Rongpeng
Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control
description The building sector has become the largest consumer of end use energy in the world, exceeding both the industry and the transportation sectors. Extensive types of energy saving techniques have been developed in the past two decades to mitigate the impact of buildings on the environment. Instead of the conventional active building environmental control approaches that solely rely on the mechanical air conditioning systems, increasing attention is given to the passive and mixed-mode approaches in buildings. This thesis aims to explore the integration of passive cooling approaches and active air conditioning approaches with different dehumidification features, by making effective use of the information on: 1) various dynamic response properties of the building system and mechanical plants, 2) diverse variations of the building boundary conditions over the whole operation process, 3) coupling effect and synergistic influence of the key operational parameters, and 4) numerous parameter conflicts in the integrated active-passive operation. These issues make the proposed integration a complex multifaceted process operation problem. In order to deal with these challenges, a systematic approach is developed by integrating a number of advanced building/system physical models and implementing well established advanced dynamic optimization algorithms. Firstly, a reduced-order model development and calibration framework is presented to generate differential-algebraic equations (DAE) based physical building models, by coupling with the high-order building energy simulations (i.e., EnergyPlus) and implementing MLE+ co-simulation programs in the Matlab platform. The reduced-order building model can describe the dynamic building thermal behaviors and address substantial time delay effects intrinsic in the building heat transfer and moisture migration. A calibration procedure is developed to balance the modelling complexity and the simulation accuracy. By making use of the advanced modeling and simulation features of EnergyPlus, the developed computational platform is able to handle real buildings with various geometric configurations, and offers the potential to cooperate with the dominant commercial building modeling software existing in the current AEC industry. Secondly, the physical model for the active air conditioning systems is developed, which is the other critical part for the dynamic optimization. By introducing and integrating a number of sub-models developed for specific building components, the model is able to specify the dynamic hygrothermal behavior and energy performance of the system under various operating conditions. Two representative air conditioning systems are investigated as the study cases: variable air volume systems (VAV) with mechanical dehumidification, and the desiccant wheel system (DW) with chemical dehumidification. The control variables and constraints representing the system operational characteristics are specified for the dynamic optimization. Thirdly, the integrated active-passive operations are formulated as dynamic optimization problems based on the above building and system physical models. The simultaneous collocation method is used in the solution algorithm to discretize the state and control variables, translating the optimization formulation into a nonlinear program (NLP). After collocation, the translated NLP problems for the daily integrated VAV/DW operation for a case zone have 1605/2181 variables, 1485/2037 equality constraints and 280/248 inequality constraints, respectively. It is found that IPOPT is able to provide the optimal solution within minutes using an 8-core 64-bit desktop, which illustrates the efficiency of the problem formulation. The case study results indicate that the approach can effectively improve the energy performance of the integrated active-passive operations, while maintaining acceptable indoor thermal comfort. Compared to the conventional local control strategies, the optimized strategies lead to remarkable energy saving percentages in different climate conditions: 29.77~48.76% for VAV and 27.85~41.33% for DW. The energy saving is contributed by the improvement of both the passive strategies (around 33%) and active strategies (around 67%). It is found that the thermal comfort constraint defined in the optimization also affects the energy saving. The total optimal energy consumption drops by around 3% if the value of the predicted percentage dissatisfied (PPD) limit is increased by one unit between 5~15%. It is also found that the fitted periodic weather data can lead to similar operation strategies in the dynamic optimization as the realistic data, and therefore can be a reasonable alternative when the more detailed realistic weather data is not available. The method described in the thesis can be generalized to supervise the operation design of building systems with different configurations.
author Zhang, Rongpeng
author_facet Zhang, Rongpeng
author_sort Zhang, Rongpeng
title Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control
title_short Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control
title_full Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control
title_fullStr Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control
title_full_unstemmed Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control
title_sort dynamic optimization of integrated active - passive strategies for building enthalpy control
publisher Research Showcase @ CMU
publishDate 2014
url http://repository.cmu.edu/dissertations/404
http://repository.cmu.edu/cgi/viewcontent.cgi?article=1404&context=dissertations
work_keys_str_mv AT zhangrongpeng dynamicoptimizationofintegratedactivepassivestrategiesforbuildingenthalpycontrol
_version_ 1716726227719421952
spelling ndltd-cmu.edu-oai-repository.cmu.edu-dissertations-14042014-12-04T03:34:33Z Dynamic Optimization of Integrated Active - Passive Strategies for Building Enthalpy Control Zhang, Rongpeng The building sector has become the largest consumer of end use energy in the world, exceeding both the industry and the transportation sectors. Extensive types of energy saving techniques have been developed in the past two decades to mitigate the impact of buildings on the environment. Instead of the conventional active building environmental control approaches that solely rely on the mechanical air conditioning systems, increasing attention is given to the passive and mixed-mode approaches in buildings. This thesis aims to explore the integration of passive cooling approaches and active air conditioning approaches with different dehumidification features, by making effective use of the information on: 1) various dynamic response properties of the building system and mechanical plants, 2) diverse variations of the building boundary conditions over the whole operation process, 3) coupling effect and synergistic influence of the key operational parameters, and 4) numerous parameter conflicts in the integrated active-passive operation. These issues make the proposed integration a complex multifaceted process operation problem. In order to deal with these challenges, a systematic approach is developed by integrating a number of advanced building/system physical models and implementing well established advanced dynamic optimization algorithms. Firstly, a reduced-order model development and calibration framework is presented to generate differential-algebraic equations (DAE) based physical building models, by coupling with the high-order building energy simulations (i.e., EnergyPlus) and implementing MLE+ co-simulation programs in the Matlab platform. The reduced-order building model can describe the dynamic building thermal behaviors and address substantial time delay effects intrinsic in the building heat transfer and moisture migration. A calibration procedure is developed to balance the modelling complexity and the simulation accuracy. By making use of the advanced modeling and simulation features of EnergyPlus, the developed computational platform is able to handle real buildings with various geometric configurations, and offers the potential to cooperate with the dominant commercial building modeling software existing in the current AEC industry. Secondly, the physical model for the active air conditioning systems is developed, which is the other critical part for the dynamic optimization. By introducing and integrating a number of sub-models developed for specific building components, the model is able to specify the dynamic hygrothermal behavior and energy performance of the system under various operating conditions. Two representative air conditioning systems are investigated as the study cases: variable air volume systems (VAV) with mechanical dehumidification, and the desiccant wheel system (DW) with chemical dehumidification. The control variables and constraints representing the system operational characteristics are specified for the dynamic optimization. Thirdly, the integrated active-passive operations are formulated as dynamic optimization problems based on the above building and system physical models. The simultaneous collocation method is used in the solution algorithm to discretize the state and control variables, translating the optimization formulation into a nonlinear program (NLP). After collocation, the translated NLP problems for the daily integrated VAV/DW operation for a case zone have 1605/2181 variables, 1485/2037 equality constraints and 280/248 inequality constraints, respectively. It is found that IPOPT is able to provide the optimal solution within minutes using an 8-core 64-bit desktop, which illustrates the efficiency of the problem formulation. The case study results indicate that the approach can effectively improve the energy performance of the integrated active-passive operations, while maintaining acceptable indoor thermal comfort. Compared to the conventional local control strategies, the optimized strategies lead to remarkable energy saving percentages in different climate conditions: 29.77~48.76% for VAV and 27.85~41.33% for DW. The energy saving is contributed by the improvement of both the passive strategies (around 33%) and active strategies (around 67%). It is found that the thermal comfort constraint defined in the optimization also affects the energy saving. The total optimal energy consumption drops by around 3% if the value of the predicted percentage dissatisfied (PPD) limit is increased by one unit between 5~15%. It is also found that the fitted periodic weather data can lead to similar operation strategies in the dynamic optimization as the realistic data, and therefore can be a reasonable alternative when the more detailed realistic weather data is not available. The method described in the thesis can be generalized to supervise the operation design of building systems with different configurations. 2014-05-01T07:00:00Z text application/pdf http://repository.cmu.edu/dissertations/404 http://repository.cmu.edu/cgi/viewcontent.cgi?article=1404&context=dissertations Dissertations Research Showcase @ CMU building energy efficiency building enthalpy control integrated active-passive strategies air conditioning and dehumidification dynamic optimization simultaneous collocation