Review of the New Zealand Standard for Concrete Structures (NZS 3101) for High Strength and Lightweight Concrete Exposed to Fire

This report describes the thermal properties, strength, and elastic modulus of lightweight, normal, and high strength concrete at elevated temperatures. Section 6 (Design for Fire Resistance) of the New Zealand standard for concrete structure (NZS3101, 1995) provides recommended values and minimum...

Full description

Bibliographic Details
Main Author: Inwood, Michael
Language:en
Published: University of Canterbury. Civil Engineering 2013
Online Access:http://hdl.handle.net/10092/8276
id ndltd-canterbury.ac.nz-oai-ir.canterbury.ac.nz-10092-8276
record_format oai_dc
spelling ndltd-canterbury.ac.nz-oai-ir.canterbury.ac.nz-10092-82762015-03-30T15:29:42ZReview of the New Zealand Standard for Concrete Structures (NZS 3101) for High Strength and Lightweight Concrete Exposed to FireInwood, MichaelThis report describes the thermal properties, strength, and elastic modulus of lightweight, normal, and high strength concrete at elevated temperatures. Section 6 (Design for Fire Resistance) of the New Zealand standard for concrete structure (NZS3101, 1995) provides recommended values and minimum requirements for concrete at elevated temperatures. These values will be reviewed with respect to overseas standards and experimental data to find their applicability to lightweight and high strength concretes. A series of tests were performed on 1m x 1m lightweight and high strength concrete specimens to determine their insulation fire resistance. The specimens were produced in three thicknesses; 60, 130, and 175mm. This follows the method of earlier tests by Wade et al. (1991) and Wade (1992) on New Zealand aggregate concretes. It was determined that the strength reduction curve given by NZS3101 over-predicts the strength of high strength concrete at elevated temperatures, though the values for elastic modulus and insulation fire resistance can be applied to high strength concrete. The insulation fire resistance, strength, and elastic modulus values given by NZS3101 were found to also apply to lightweight concrete. The report recommends a change to the elastic modulus curve given in NZS3101. The purpose of this is to give consistency between the strength and elastic modulus curves, which do not currently reach zero at the same temperature.University of Canterbury. Civil Engineering2013-09-17T22:24:44Z2013-09-17T22:24:44Z1999ReportText1173-5996http://hdl.handle.net/10092/8276enFire Engineering Research Report 99/10NZCUCopyright Michael Inwoodhttp://library.canterbury.ac.nz/thesis/etheses_copyright.shtml
collection NDLTD
language en
sources NDLTD
description This report describes the thermal properties, strength, and elastic modulus of lightweight, normal, and high strength concrete at elevated temperatures. Section 6 (Design for Fire Resistance) of the New Zealand standard for concrete structure (NZS3101, 1995) provides recommended values and minimum requirements for concrete at elevated temperatures. These values will be reviewed with respect to overseas standards and experimental data to find their applicability to lightweight and high strength concretes. A series of tests were performed on 1m x 1m lightweight and high strength concrete specimens to determine their insulation fire resistance. The specimens were produced in three thicknesses; 60, 130, and 175mm. This follows the method of earlier tests by Wade et al. (1991) and Wade (1992) on New Zealand aggregate concretes. It was determined that the strength reduction curve given by NZS3101 over-predicts the strength of high strength concrete at elevated temperatures, though the values for elastic modulus and insulation fire resistance can be applied to high strength concrete. The insulation fire resistance, strength, and elastic modulus values given by NZS3101 were found to also apply to lightweight concrete. The report recommends a change to the elastic modulus curve given in NZS3101. The purpose of this is to give consistency between the strength and elastic modulus curves, which do not currently reach zero at the same temperature.
author Inwood, Michael
spellingShingle Inwood, Michael
Review of the New Zealand Standard for Concrete Structures (NZS 3101) for High Strength and Lightweight Concrete Exposed to Fire
author_facet Inwood, Michael
author_sort Inwood, Michael
title Review of the New Zealand Standard for Concrete Structures (NZS 3101) for High Strength and Lightweight Concrete Exposed to Fire
title_short Review of the New Zealand Standard for Concrete Structures (NZS 3101) for High Strength and Lightweight Concrete Exposed to Fire
title_full Review of the New Zealand Standard for Concrete Structures (NZS 3101) for High Strength and Lightweight Concrete Exposed to Fire
title_fullStr Review of the New Zealand Standard for Concrete Structures (NZS 3101) for High Strength and Lightweight Concrete Exposed to Fire
title_full_unstemmed Review of the New Zealand Standard for Concrete Structures (NZS 3101) for High Strength and Lightweight Concrete Exposed to Fire
title_sort review of the new zealand standard for concrete structures (nzs 3101) for high strength and lightweight concrete exposed to fire
publisher University of Canterbury. Civil Engineering
publishDate 2013
url http://hdl.handle.net/10092/8276
work_keys_str_mv AT inwoodmichael reviewofthenewzealandstandardforconcretestructuresnzs3101forhighstrengthandlightweightconcreteexposedtofire
_version_ 1716798995015139328