Class A Foam Water Sprinkler Systems

Class A foam is often used in the suppression of wildland and structural fires, with manual application methods. This report examines the feasibility of utilising class A foam extinguishing medium in automatic wet pipe sprinkler systems. Previous researchers report that for certain applications the...

Full description

Bibliographic Details
Main Author: Hipkins, David B
Language:en
Published: University of Canterbury. Civil Engineering 2013
Online Access:http://hdl.handle.net/10092/8274
id ndltd-canterbury.ac.nz-oai-ir.canterbury.ac.nz-10092-8274
record_format oai_dc
spelling ndltd-canterbury.ac.nz-oai-ir.canterbury.ac.nz-10092-82742015-03-30T15:29:42ZClass A Foam Water Sprinkler SystemsHipkins, David BClass A foam is often used in the suppression of wildland and structural fires, with manual application methods. This report examines the feasibility of utilising class A foam extinguishing medium in automatic wet pipe sprinkler systems. Previous researchers report that for certain applications the addition of class A foam solution to a sprinkler system increases suppression effectiveness. Researchers investigating applications with manual fire fighting techniques, using this extinguishing medium, report mixed conclusions. The integration of class A foam hardware with standard wet pipe sprinkler technology is discussed. Consideration is given to potential corrosion effects and compatibility with sprinkler hardware items. A review of environmental issues revealed that some products are readily biodegradable, while others are not, and that results vary with the test method used. Tests undertaken to investigate the relationship between the applied sprinkler head pressure and the foam expansion ratio, revealed that only a slight increase in the expansion ratio occurred when the pressure was increased from 50 kPa to 85 kPa. Expansion ratios obtained were similar to those obtained by other researchers using AFFF type foam solution. Foam-water distribution tests indicated that the distribution densities obtained with class A foam sprinkler arrays are within close proximity to the densities obtained using pure water. It is suggested that future work in this area should be based around the protection of extreme class A hazard type fires.University of Canterbury. Civil Engineering2013-09-17T22:24:00Z2013-09-17T22:24:00Z1999ReportText1173-5996http://hdl.handle.net/10092/8274enFire Engineering Research Report 99/9NZCUCopyright David B Hipkinshttp://library.canterbury.ac.nz/thesis/etheses_copyright.shtml
collection NDLTD
language en
sources NDLTD
description Class A foam is often used in the suppression of wildland and structural fires, with manual application methods. This report examines the feasibility of utilising class A foam extinguishing medium in automatic wet pipe sprinkler systems. Previous researchers report that for certain applications the addition of class A foam solution to a sprinkler system increases suppression effectiveness. Researchers investigating applications with manual fire fighting techniques, using this extinguishing medium, report mixed conclusions. The integration of class A foam hardware with standard wet pipe sprinkler technology is discussed. Consideration is given to potential corrosion effects and compatibility with sprinkler hardware items. A review of environmental issues revealed that some products are readily biodegradable, while others are not, and that results vary with the test method used. Tests undertaken to investigate the relationship between the applied sprinkler head pressure and the foam expansion ratio, revealed that only a slight increase in the expansion ratio occurred when the pressure was increased from 50 kPa to 85 kPa. Expansion ratios obtained were similar to those obtained by other researchers using AFFF type foam solution. Foam-water distribution tests indicated that the distribution densities obtained with class A foam sprinkler arrays are within close proximity to the densities obtained using pure water. It is suggested that future work in this area should be based around the protection of extreme class A hazard type fires.
author Hipkins, David B
spellingShingle Hipkins, David B
Class A Foam Water Sprinkler Systems
author_facet Hipkins, David B
author_sort Hipkins, David B
title Class A Foam Water Sprinkler Systems
title_short Class A Foam Water Sprinkler Systems
title_full Class A Foam Water Sprinkler Systems
title_fullStr Class A Foam Water Sprinkler Systems
title_full_unstemmed Class A Foam Water Sprinkler Systems
title_sort class a foam water sprinkler systems
publisher University of Canterbury. Civil Engineering
publishDate 2013
url http://hdl.handle.net/10092/8274
work_keys_str_mv AT hipkinsdavidb classafoamwatersprinklersystems
_version_ 1716798994413256704