The Influence of Non-Uniform Electric Fields on Combusion Processes
This report investigates the application of electric fields to flames and fires. An extensive literature review covers the empirical data available on the electric field effects on combustion characteristics. Authors attribute the mechanism to electrostatic forces on ions and an electrically induced...
Main Author: | |
---|---|
Language: | en |
Published: |
University of Canterbury. Civil Engineering
2013
|
Online Access: | http://hdl.handle.net/10092/8251 |
id |
ndltd-canterbury.ac.nz-oai-ir.canterbury.ac.nz-10092-8251 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-canterbury.ac.nz-oai-ir.canterbury.ac.nz-10092-82512015-03-30T15:29:38ZThe Influence of Non-Uniform Electric Fields on Combusion ProcessesBelsham, M AThis report investigates the application of electric fields to flames and fires. An extensive literature review covers the empirical data available on the electric field effects on combustion characteristics. Authors attribute the mechanism to electrostatic forces on ions and an electrically induced air movement called corona wind Experimentation was carried out which verifies some of these effects. A test was performed to show that wood becomes fire resistant when a DC high voltage on the onset of breakdown was applied between the wood and the heat source. Maximum burning resistance was achieved at the electrical breakdown voltage which coincided with a leakage current flow of approximately 20 μA. At lower voltages, wood fire enhancement was discovered in some circumstances. High voltage was shown to have a greater influence on the burning from a diffusion flame than by a premixed flame heat source. The extent of burning was dependent on electrode shape with a single protruding nail causing more resistance to burning than other electrode geometries tried. Voltage polarity was shown to not to be significant to the extent of the burning. High voltage was also shown to significantly reduce the extent of wood burning from a horizontal radiant heat source. It was discovered that in some circumstances, high voltage will extinguish flames on burning wood. This electrical control of combustion was discovered to have large influence on combustion by convective heating but little effect on radiant heating. The mechanism is suggested to be a complex mixture of corona wind, electrostatic force on flame ions and electrostatic disruption of convective heat flow.University of Canterbury. Civil Engineering2013-09-17T22:08:23Z2013-09-17T22:08:23Z1996TextReport1173-5996http://hdl.handle.net/10092/8251enFire Engineering Research report 96/1NZCUCopyright M A Belshamhttp://library.canterbury.ac.nz/thesis/etheses_copyright.shtml |
collection |
NDLTD |
language |
en |
sources |
NDLTD |
description |
This report investigates the application of electric fields to flames and fires. An extensive literature review covers the empirical data available on the electric field effects on combustion characteristics. Authors attribute the mechanism to electrostatic forces on ions and an electrically induced air movement called corona wind Experimentation was carried out which verifies some of these effects. A test was performed to show that wood becomes fire resistant when a DC high voltage on the onset of breakdown was applied between the wood and the heat source. Maximum burning resistance was achieved at the electrical breakdown voltage which coincided with a leakage current flow of approximately 20 μA. At lower voltages, wood fire enhancement was discovered in some circumstances. High voltage was shown to have a greater influence on the burning from a diffusion flame than by a premixed flame heat source. The extent of burning was dependent on electrode shape with a single protruding nail causing more resistance to burning than other electrode geometries tried. Voltage polarity was shown to not to be significant to the extent of the burning.
High voltage was also shown to significantly reduce the extent of wood burning from a horizontal radiant heat source. It was discovered that in some circumstances, high voltage will extinguish flames on burning wood. This electrical control of combustion was discovered to have large influence on combustion by convective heating but little effect on radiant heating. The mechanism is suggested to be a complex mixture of corona wind, electrostatic force on flame ions and electrostatic disruption of convective heat flow. |
author |
Belsham, M A |
spellingShingle |
Belsham, M A The Influence of Non-Uniform Electric Fields on Combusion Processes |
author_facet |
Belsham, M A |
author_sort |
Belsham, M A |
title |
The Influence of Non-Uniform Electric Fields on Combusion Processes |
title_short |
The Influence of Non-Uniform Electric Fields on Combusion Processes |
title_full |
The Influence of Non-Uniform Electric Fields on Combusion Processes |
title_fullStr |
The Influence of Non-Uniform Electric Fields on Combusion Processes |
title_full_unstemmed |
The Influence of Non-Uniform Electric Fields on Combusion Processes |
title_sort |
influence of non-uniform electric fields on combusion processes |
publisher |
University of Canterbury. Civil Engineering |
publishDate |
2013 |
url |
http://hdl.handle.net/10092/8251 |
work_keys_str_mv |
AT belshamma theinfluenceofnonuniformelectricfieldsoncombusionprocesses AT belshamma influenceofnonuniformelectricfieldsoncombusionprocesses |
_version_ |
1716798987490557952 |