A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver

Imaging the dome of the liver can be a very challenging area to image by Ultrasound. Due to its position inside the ribcage there can be difficulty with rib shadowing artifacts causing the sonographer to miss small lesions. The X6–1 Matrix transducer is one of the newest of its kind and claims to be...

Full description

Bibliographic Details
Main Author: Subaran, Sarah Samira
Language:en_US
Published: 2016
Subjects:
MRI
Online Access:https://hdl.handle.net/2144/14393
id ndltd-bu.edu-oai-open.bu.edu-2144-14393
record_format oai_dc
spelling ndltd-bu.edu-oai-open.bu.edu-2144-143932019-01-08T15:36:41Z A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver Subaran, Sarah Samira Medical imaging Imaging Liver MRI Ultrasound Imaging the dome of the liver can be a very challenging area to image by Ultrasound. Due to its position inside the ribcage there can be difficulty with rib shadowing artifacts causing the sonographer to miss small lesions. The X6–1 Matrix transducer is one of the newest of its kind and claims to be the better multi-use transducer. Its larger aperture reduces rib artifacts and is composed of PureWave Crystal Technology. A phantom will serve as a great approach in this abdominal study to visually compare the lesions between MRI (gold standard) and the new X6–1 Matrix Ultrasound transducer. The X6–1 transducers did reveal minimal rib shadowing and the small lesions were identified. 2016-02-11T19:30:54Z 2016-02-11T19:30:54Z 2014 2016-01-22T18:56:46Z Thesis/Dissertation https://hdl.handle.net/2144/14393 en_US
collection NDLTD
language en_US
sources NDLTD
topic Medical imaging
Imaging
Liver
MRI
Ultrasound
spellingShingle Medical imaging
Imaging
Liver
MRI
Ultrasound
Subaran, Sarah Samira
A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver
description Imaging the dome of the liver can be a very challenging area to image by Ultrasound. Due to its position inside the ribcage there can be difficulty with rib shadowing artifacts causing the sonographer to miss small lesions. The X6–1 Matrix transducer is one of the newest of its kind and claims to be the better multi-use transducer. Its larger aperture reduces rib artifacts and is composed of PureWave Crystal Technology. A phantom will serve as a great approach in this abdominal study to visually compare the lesions between MRI (gold standard) and the new X6–1 Matrix Ultrasound transducer. The X6–1 transducers did reveal minimal rib shadowing and the small lesions were identified.
author Subaran, Sarah Samira
author_facet Subaran, Sarah Samira
author_sort Subaran, Sarah Samira
title A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver
title_short A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver
title_full A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver
title_fullStr A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver
title_full_unstemmed A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver
title_sort visual comparison between the ultrasound x6-1 matrix transducer and mri in lesion detection in the dome of the liver
publishDate 2016
url https://hdl.handle.net/2144/14393
work_keys_str_mv AT subaransarahsamira avisualcomparisonbetweentheultrasoundx61matrixtransducerandmriinlesiondetectioninthedomeoftheliver
AT subaransarahsamira visualcomparisonbetweentheultrasoundx61matrixtransducerandmriinlesiondetectioninthedomeoftheliver
_version_ 1718811019913986048