Medical applications of attenuation numbers in computerised tomography

A computerised tomographic scanner is used to obtain sectional images of biological structures. The success of any research program in CT scanning depends on an understanding of the derivation of CT numbers and what physical changes cause them to vary. An analysis of attenuation data gave an empiric...

Full description

Bibliographic Details
Main Author: Williams, Gareth
Published: University of Surrey 1980
Subjects:
530
Online Access:https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.751798
id ndltd-bl.uk-oai-ethos.bl.uk-751798
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-7517982019-03-05T15:41:41ZMedical applications of attenuation numbers in computerised tomographyWilliams, Gareth1980A computerised tomographic scanner is used to obtain sectional images of biological structures. The success of any research program in CT scanning depends on an understanding of the derivation of CT numbers and what physical changes cause them to vary. An analysis of attenuation data gave an empirical function which was used to calculate photon attenuation cross sections. The CT numbers for biological materials were calculated and compared with measurements made by RaO, Gregg and Phelps. Spectral changes along ray paths through biological materials were studied, spectrum mean energies and total photon fluence were calculated for several phantom sizes and for the human body and head. The monochromatic equivalent energy was shown by theory and experiment to be similar to the scan averaged spectrum mean energy. Error sources were considered and the ability of the software to minimise spectral errors was studied using a constant size phantom in different fields. CT numbers increased with increasing field size and it was shown that dual wedge-energy measurements allowed correction for spectral change. Experiments with corpses proved that such a correction technique could be applied and that the reproducibility of CT numbers was +/- 0. 25 EU for liver tissue and trabecular bone. In vivo and in vitro measurements of the attenuation coefficient for trabecular bone were made using the EMI and ISOTOM CT scanners. Spectral hardening v/as shown not to be significant. The stability of the air scale factor was tested using patients and shown to be better than +/- 1 %. Air-water scale factors were measured and tested using glucose solutions. Measurements with haemochromatosis (iron) and fatty liver patients showed good correlation between measured liver CT numbers and liver biopsy estimates. Trabecular bone measurements in the distal radius, using the ISOTOM scanner, correlated well with EMI CT scanner vertebral bone CT numbers.530University of Surreyhttps://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.751798http://epubs.surrey.ac.uk/848574/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 530
spellingShingle 530
Williams, Gareth
Medical applications of attenuation numbers in computerised tomography
description A computerised tomographic scanner is used to obtain sectional images of biological structures. The success of any research program in CT scanning depends on an understanding of the derivation of CT numbers and what physical changes cause them to vary. An analysis of attenuation data gave an empirical function which was used to calculate photon attenuation cross sections. The CT numbers for biological materials were calculated and compared with measurements made by RaO, Gregg and Phelps. Spectral changes along ray paths through biological materials were studied, spectrum mean energies and total photon fluence were calculated for several phantom sizes and for the human body and head. The monochromatic equivalent energy was shown by theory and experiment to be similar to the scan averaged spectrum mean energy. Error sources were considered and the ability of the software to minimise spectral errors was studied using a constant size phantom in different fields. CT numbers increased with increasing field size and it was shown that dual wedge-energy measurements allowed correction for spectral change. Experiments with corpses proved that such a correction technique could be applied and that the reproducibility of CT numbers was +/- 0. 25 EU for liver tissue and trabecular bone. In vivo and in vitro measurements of the attenuation coefficient for trabecular bone were made using the EMI and ISOTOM CT scanners. Spectral hardening v/as shown not to be significant. The stability of the air scale factor was tested using patients and shown to be better than +/- 1 %. Air-water scale factors were measured and tested using glucose solutions. Measurements with haemochromatosis (iron) and fatty liver patients showed good correlation between measured liver CT numbers and liver biopsy estimates. Trabecular bone measurements in the distal radius, using the ISOTOM scanner, correlated well with EMI CT scanner vertebral bone CT numbers.
author Williams, Gareth
author_facet Williams, Gareth
author_sort Williams, Gareth
title Medical applications of attenuation numbers in computerised tomography
title_short Medical applications of attenuation numbers in computerised tomography
title_full Medical applications of attenuation numbers in computerised tomography
title_fullStr Medical applications of attenuation numbers in computerised tomography
title_full_unstemmed Medical applications of attenuation numbers in computerised tomography
title_sort medical applications of attenuation numbers in computerised tomography
publisher University of Surrey
publishDate 1980
url https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.751798
work_keys_str_mv AT williamsgareth medicalapplicationsofattenuationnumbersincomputerisedtomography
_version_ 1718995987086704640