The influence of stent geometry on haemodynamics and endothelialisation

Every year, millions of people worldwide undergo stent implantation to widen narrowed arteries or to redirect blood away from aneurysms. The rapid post-operative regrowth of a healthy endothelial layer, a key factor in stented artery repair, would reduce complications and improve quality of life for...

Full description

Bibliographic Details
Main Author: Boldock, Luke
Other Authors: Perrault, C. M.
Published: University of Sheffield 2017
Subjects:
621
Online Access:https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.733601
id ndltd-bl.uk-oai-ethos.bl.uk-733601
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-7336012019-03-05T15:39:32ZThe influence of stent geometry on haemodynamics and endothelialisationBoldock, LukePerrault, C. M.2017Every year, millions of people worldwide undergo stent implantation to widen narrowed arteries or to redirect blood away from aneurysms. The rapid post-operative regrowth of a healthy endothelial layer, a key factor in stented artery repair, would reduce complications and improve quality of life for many patients. While this has long been a clinical or pharmaceutical issue, this project considers the role of local haemodynamics, specifically the effects of stent-modified wall shear stress on the endothelium. Endothelial cells have a strong mechanobiological response to wall shear stress magnitude, direction and time variance. To understand the impact of stent geometry on this response through altered fluid dynamics, a novel model vessel was developed for the deployment of a wide range of coronary and flow diverter stents in vitro. The model allowed the observation of both endothelial cell migration and, via particle tracking, disturbed flow within the stents. High-resolution micro-computed tomography scanning techniques replicated stent geometry in silico, enabling computational fluid dynamics simulations for the assessment of wall shear stress distribution. Coronary stents greatly influenced fluid flow. The orientation and distribution of tracked particle streamlines were transformed proximal to stents struts, which were also areas of reduced wall shear stress. These areas correlated with zones of reduced cell migration. Flow diverter stents had a lesser impact on observable particle flow; yet endothelial cell migration within them was completely arrested. This is likely due to their structure directing flow away from the wall and reducing shear stress to an even greater extent that coronary stents, over a more substantial area. Dissimilar cell migration between coronary and flow diverter stents is a point of possible significance as the two are treated alike with respect to post-operative care and medication. Continued analysis of various geometries may enable the efficacy of individual stent designs to be quantified or predicted. By applying this knowledge in the future, careful stent design could reduce their impact, or exert an intentional, active influence on endothelial cells, to optimise the healing process.621University of Sheffieldhttps://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.733601http://etheses.whiterose.ac.uk/19272/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 621
spellingShingle 621
Boldock, Luke
The influence of stent geometry on haemodynamics and endothelialisation
description Every year, millions of people worldwide undergo stent implantation to widen narrowed arteries or to redirect blood away from aneurysms. The rapid post-operative regrowth of a healthy endothelial layer, a key factor in stented artery repair, would reduce complications and improve quality of life for many patients. While this has long been a clinical or pharmaceutical issue, this project considers the role of local haemodynamics, specifically the effects of stent-modified wall shear stress on the endothelium. Endothelial cells have a strong mechanobiological response to wall shear stress magnitude, direction and time variance. To understand the impact of stent geometry on this response through altered fluid dynamics, a novel model vessel was developed for the deployment of a wide range of coronary and flow diverter stents in vitro. The model allowed the observation of both endothelial cell migration and, via particle tracking, disturbed flow within the stents. High-resolution micro-computed tomography scanning techniques replicated stent geometry in silico, enabling computational fluid dynamics simulations for the assessment of wall shear stress distribution. Coronary stents greatly influenced fluid flow. The orientation and distribution of tracked particle streamlines were transformed proximal to stents struts, which were also areas of reduced wall shear stress. These areas correlated with zones of reduced cell migration. Flow diverter stents had a lesser impact on observable particle flow; yet endothelial cell migration within them was completely arrested. This is likely due to their structure directing flow away from the wall and reducing shear stress to an even greater extent that coronary stents, over a more substantial area. Dissimilar cell migration between coronary and flow diverter stents is a point of possible significance as the two are treated alike with respect to post-operative care and medication. Continued analysis of various geometries may enable the efficacy of individual stent designs to be quantified or predicted. By applying this knowledge in the future, careful stent design could reduce their impact, or exert an intentional, active influence on endothelial cells, to optimise the healing process.
author2 Perrault, C. M.
author_facet Perrault, C. M.
Boldock, Luke
author Boldock, Luke
author_sort Boldock, Luke
title The influence of stent geometry on haemodynamics and endothelialisation
title_short The influence of stent geometry on haemodynamics and endothelialisation
title_full The influence of stent geometry on haemodynamics and endothelialisation
title_fullStr The influence of stent geometry on haemodynamics and endothelialisation
title_full_unstemmed The influence of stent geometry on haemodynamics and endothelialisation
title_sort influence of stent geometry on haemodynamics and endothelialisation
publisher University of Sheffield
publishDate 2017
url https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.733601
work_keys_str_mv AT boldockluke theinfluenceofstentgeometryonhaemodynamicsandendothelialisation
AT boldockluke influenceofstentgeometryonhaemodynamicsandendothelialisation
_version_ 1718995781633966080