Optimised detectors for integration of NMR with microfluidic devices

An optimised nuclear magnetic resonance (NMR) detector design has been developed to allow in situ NMR observation of sub mM concentrations of sample within a 2 l sample volume on a microfluidic chip. The detector is a new design of double micro-stripline detector that is compatible with functional l...

Full description

Bibliographic Details
Main Author: Finch, Graeme Richard
Other Authors: Utz, M.
Published: University of Southampton 2017
Subjects:
543
Online Access:https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.714596
id ndltd-bl.uk-oai-ethos.bl.uk-714596
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-7145962018-09-05T03:36:04ZOptimised detectors for integration of NMR with microfluidic devicesFinch, Graeme RichardUtz, M.2017An optimised nuclear magnetic resonance (NMR) detector design has been developed to allow in situ NMR observation of sub mM concentrations of sample within a 2 l sample volume on a microfluidic chip. The detector is a new design of double micro-stripline detector that is compatible with functional lab-on-a-chip devices. The design has been optimised using nite element analysis taking into account both the shape of the sample chamber and the resonator. The sensitivity of this detector compares favourably with other micro-NMR systems. The ability to observe low concentrations allows direct analysis of cell metabolomics on a chip within 20 minutes of experiment time. The detector has been adapted to resonate at 2 frequencies. This opens the possibility of heteronuclear NMR experiments without compromising the sensitivity of the probe. The sensitivity is sufficient to demonstrate the ability to study changes in the structure of proteins when binding to a substrate. Also explored in this work is another detector design the inductively coupled planar microcoil. Finite element analysis has allowed accurate simulation of these microcoils.543University of Southamptonhttps://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.714596https://eprints.soton.ac.uk/409692/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 543
spellingShingle 543
Finch, Graeme Richard
Optimised detectors for integration of NMR with microfluidic devices
description An optimised nuclear magnetic resonance (NMR) detector design has been developed to allow in situ NMR observation of sub mM concentrations of sample within a 2 l sample volume on a microfluidic chip. The detector is a new design of double micro-stripline detector that is compatible with functional lab-on-a-chip devices. The design has been optimised using nite element analysis taking into account both the shape of the sample chamber and the resonator. The sensitivity of this detector compares favourably with other micro-NMR systems. The ability to observe low concentrations allows direct analysis of cell metabolomics on a chip within 20 minutes of experiment time. The detector has been adapted to resonate at 2 frequencies. This opens the possibility of heteronuclear NMR experiments without compromising the sensitivity of the probe. The sensitivity is sufficient to demonstrate the ability to study changes in the structure of proteins when binding to a substrate. Also explored in this work is another detector design the inductively coupled planar microcoil. Finite element analysis has allowed accurate simulation of these microcoils.
author2 Utz, M.
author_facet Utz, M.
Finch, Graeme Richard
author Finch, Graeme Richard
author_sort Finch, Graeme Richard
title Optimised detectors for integration of NMR with microfluidic devices
title_short Optimised detectors for integration of NMR with microfluidic devices
title_full Optimised detectors for integration of NMR with microfluidic devices
title_fullStr Optimised detectors for integration of NMR with microfluidic devices
title_full_unstemmed Optimised detectors for integration of NMR with microfluidic devices
title_sort optimised detectors for integration of nmr with microfluidic devices
publisher University of Southampton
publishDate 2017
url https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.714596
work_keys_str_mv AT finchgraemerichard optimiseddetectorsforintegrationofnmrwithmicrofluidicdevices
_version_ 1718730957065814016