Metal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effects

Metal on metal (MoM) hip replacements consist of a cobalt-chromium-molybdenum alloy femoral head which articulates against an acetabular cup manufactured from similar material. MoM hip replacements were introduced in the 1980s. It was thought that the overall reduction in volumetric wear as well as...

Full description

Bibliographic Details
Main Author: Langton, David
Published: University of Newcastle upon Tyne 2013
Subjects:
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.627737
id ndltd-bl.uk-oai-ethos.bl.uk-627737
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-6277372017-11-03T03:13:46ZMetal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effectsLangton, David2013Metal on metal (MoM) hip replacements consist of a cobalt-chromium-molybdenum alloy femoral head which articulates against an acetabular cup manufactured from similar material. MoM hip replacements were introduced in the 1980s. It was thought that the overall reduction in volumetric wear as well as the avoidance of polyethylene would lead to greater longevity of these prostheses. There had been isolated reports of adverse tissue reactions with previous generations of MoM devices but it was thought that improved manufacturing technology would eliminate these problems. In the 1990s, the Birmingham Hip Resurfacing (BHR) was developed. The positive mid-term results of this device led to a rapid increase in the use of the BHR throughout the world. For obvious reasons, the enhanced stability large diameter bearings provided proved extremely attractive to surgeons and patients. Manufacturers therefore began to develop total hip replacement systems for patients unsuitable for the resurfacing procedure. These systems used bearings of size 36mm and greater, in Contrast to the existing 28mm Metasul device. From 2005 onwards there began to emerge increasing numbers of reports of local complications in the tissues adjacent to MoM prostheses. These reactions included sterile masses, tissue destruction and osteolysis. The incidence of these tissue reactions was unknown, as were the risk factors for their development. This piece of work sought to quantity the volumetric and linear wear rates of failed MoM hips and to investigate the relationship these wear rates and a number of clinical parameters. These parameters included blood, serum and hip fluid chromium and cobalt concentrations, and the macro and microscopic appearance of periprosthetic tissue at revision surgery. In this way it was hoped that component design, host and surgical factors leading to adverse tissue reactions could be identified and potentially eliminated.617.5810592Hip replacementsUniversity of Newcastle upon Tynehttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.627737http://hdl.handle.net/10443/3629Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 617.5810592
Hip replacements
spellingShingle 617.5810592
Hip replacements
Langton, David
Metal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effects
description Metal on metal (MoM) hip replacements consist of a cobalt-chromium-molybdenum alloy femoral head which articulates against an acetabular cup manufactured from similar material. MoM hip replacements were introduced in the 1980s. It was thought that the overall reduction in volumetric wear as well as the avoidance of polyethylene would lead to greater longevity of these prostheses. There had been isolated reports of adverse tissue reactions with previous generations of MoM devices but it was thought that improved manufacturing technology would eliminate these problems. In the 1990s, the Birmingham Hip Resurfacing (BHR) was developed. The positive mid-term results of this device led to a rapid increase in the use of the BHR throughout the world. For obvious reasons, the enhanced stability large diameter bearings provided proved extremely attractive to surgeons and patients. Manufacturers therefore began to develop total hip replacement systems for patients unsuitable for the resurfacing procedure. These systems used bearings of size 36mm and greater, in Contrast to the existing 28mm Metasul device. From 2005 onwards there began to emerge increasing numbers of reports of local complications in the tissues adjacent to MoM prostheses. These reactions included sterile masses, tissue destruction and osteolysis. The incidence of these tissue reactions was unknown, as were the risk factors for their development. This piece of work sought to quantity the volumetric and linear wear rates of failed MoM hips and to investigate the relationship these wear rates and a number of clinical parameters. These parameters included blood, serum and hip fluid chromium and cobalt concentrations, and the macro and microscopic appearance of periprosthetic tissue at revision surgery. In this way it was hoped that component design, host and surgical factors leading to adverse tissue reactions could be identified and potentially eliminated.
author Langton, David
author_facet Langton, David
author_sort Langton, David
title Metal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effects
title_short Metal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effects
title_full Metal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effects
title_fullStr Metal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effects
title_full_unstemmed Metal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effects
title_sort metal debris release from metal-on-metal hip arthroplasty : mechanism, quantification and clinical effects
publisher University of Newcastle upon Tyne
publishDate 2013
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.627737
work_keys_str_mv AT langtondavid metaldebrisreleasefrommetalonmetalhiparthroplastymechanismquantificationandclinicaleffects
_version_ 1718559323233189888