The development of an electron spin resonance biosensor, with both biomedical and biophysical implications

There is a need for new and innovative biosensing technologies. Biosensors are extremely useful in: relieving the diagnostics burden of healthcare professionals, environmental safety screening, drug and food testing, etc. Here, we have utilized the inherent advantages of continuous wave electron spi...

Full description

Bibliographic Details
Main Author: Sanchania, V.
Published: University College London (University of London) 2014
Subjects:
570
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.626531
id ndltd-bl.uk-oai-ethos.bl.uk-626531
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-6265312016-08-04T03:28:51ZThe development of an electron spin resonance biosensor, with both biomedical and biophysical implicationsSanchania, V.2014There is a need for new and innovative biosensing technologies. Biosensors are extremely useful in: relieving the diagnostics burden of healthcare professionals, environmental safety screening, drug and food testing, etc. Here, we have utilized the inherent advantages of continuous wave electron spin resonance (CW-ESR) over other biosensing platforms to develop ESR biosensing metrologies. Initially, we extrapolate the work of the ESR biosensing company Syva, established in the 1970’s. They previously performed various small molecule competition immunoassays, through spin labeling of small antigens e.g. morphine, but not large biomolecules. We attempted to strategically develop an assay for large biomolecule sensing - using similar assay principles to Syva enabled by epitope tagging. However, competition immunoassays suffer from a range of pitfalls, so a CWESR direct immunoassay was developed for the first time. Consequently, a proof-of-concept ESR direct immunoassay for a cystine stabilized single chain variable fragment (sscFv) for the carcinoembryonic antigen (CEA) was developed using disulfide bond labeling. The direct immunoassay was performed successfully in human plasma and whole human blood, both without the need for any sample pretreatment. Furthermore, using the direct immunoassay method, a thermal stability shift assay (TSSA) was developed. To truly evaluate the potential of the direct immunoassay, the disulfide bridging nitroxide spin labeling methodology was utilized to modify full-length antibodies. An anti-FLAG antibody, two human IgG1 antibodies varying in light chains only and anti-C-reactive protein (CRP) antibodies were modified and show interesting binding effects. Finally, a competition glucose sensing assay utilizing the displacement of concanavalin-A bound nitroxide spin labeled mannan complexes by glucose and a direct sensing assay utilizing chromium ions were developed. Overall, the biosensing capabilities of ESR are explored, and the respective advantages and disadvantages are discussed. Furthermore, the commercialization potential of the work is considered and critically evaluated.570University College London (University of London)http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.626531http://discovery.ucl.ac.uk/1425682/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 570
spellingShingle 570
Sanchania, V.
The development of an electron spin resonance biosensor, with both biomedical and biophysical implications
description There is a need for new and innovative biosensing technologies. Biosensors are extremely useful in: relieving the diagnostics burden of healthcare professionals, environmental safety screening, drug and food testing, etc. Here, we have utilized the inherent advantages of continuous wave electron spin resonance (CW-ESR) over other biosensing platforms to develop ESR biosensing metrologies. Initially, we extrapolate the work of the ESR biosensing company Syva, established in the 1970’s. They previously performed various small molecule competition immunoassays, through spin labeling of small antigens e.g. morphine, but not large biomolecules. We attempted to strategically develop an assay for large biomolecule sensing - using similar assay principles to Syva enabled by epitope tagging. However, competition immunoassays suffer from a range of pitfalls, so a CWESR direct immunoassay was developed for the first time. Consequently, a proof-of-concept ESR direct immunoassay for a cystine stabilized single chain variable fragment (sscFv) for the carcinoembryonic antigen (CEA) was developed using disulfide bond labeling. The direct immunoassay was performed successfully in human plasma and whole human blood, both without the need for any sample pretreatment. Furthermore, using the direct immunoassay method, a thermal stability shift assay (TSSA) was developed. To truly evaluate the potential of the direct immunoassay, the disulfide bridging nitroxide spin labeling methodology was utilized to modify full-length antibodies. An anti-FLAG antibody, two human IgG1 antibodies varying in light chains only and anti-C-reactive protein (CRP) antibodies were modified and show interesting binding effects. Finally, a competition glucose sensing assay utilizing the displacement of concanavalin-A bound nitroxide spin labeled mannan complexes by glucose and a direct sensing assay utilizing chromium ions were developed. Overall, the biosensing capabilities of ESR are explored, and the respective advantages and disadvantages are discussed. Furthermore, the commercialization potential of the work is considered and critically evaluated.
author Sanchania, V.
author_facet Sanchania, V.
author_sort Sanchania, V.
title The development of an electron spin resonance biosensor, with both biomedical and biophysical implications
title_short The development of an electron spin resonance biosensor, with both biomedical and biophysical implications
title_full The development of an electron spin resonance biosensor, with both biomedical and biophysical implications
title_fullStr The development of an electron spin resonance biosensor, with both biomedical and biophysical implications
title_full_unstemmed The development of an electron spin resonance biosensor, with both biomedical and biophysical implications
title_sort development of an electron spin resonance biosensor, with both biomedical and biophysical implications
publisher University College London (University of London)
publishDate 2014
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.626531
work_keys_str_mv AT sanchaniav thedevelopmentofanelectronspinresonancebiosensorwithbothbiomedicalandbiophysicalimplications
AT sanchaniav developmentofanelectronspinresonancebiosensorwithbothbiomedicalandbiophysicalimplications
_version_ 1718369617128194048