Utilisation of the natural self-diffusion of water to make physiological measurements in human brain

Magnetic resonance imaging enables the parameterisation of various physiological processes by comparison of a baseline set of images with a set of images taken after some perturbation of the nuclear spins. By linking this perturbation to a physiological process, changes in signal intensity become a...

Full description

Bibliographic Details
Main Author: Green, H. A. L.
Published: University of Cambridge 2004
Subjects:
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.599663
id ndltd-bl.uk-oai-ethos.bl.uk-599663
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-5996632015-03-20T05:52:36ZUtilisation of the natural self-diffusion of water to make physiological measurements in human brainGreen, H. A. L.2004Magnetic resonance imaging enables the parameterisation of various physiological processes by comparison of a baseline set of images with a set of images taken after some perturbation of the nuclear spins. By linking this perturbation to a physiological process, changes in signal intensity become a proxy measure of that physiological process. This thesis is concerned with the accuracy and meaning of the measurements made using the natural self-diffusion of water. The first section deals with diffusion tensor measurements, which are three-dimensional measures of water self-diffusion using linear magnetic field gradients. The thesis looks in turn at the effect of signal noise, and partial volume effects on parameters such as the mean diffusivity, the eigenvalues and the fractional anisotropy of the diffusion tensor. The accuracy of the technique, as indicated by the results of numerical simulations, is compared to those acquired from phantom and brain imaging. These results provide an estimate of the dependence of diffusion measurements on technique. The coefficient of variation of diffusion measurements is shown to depend on the metric being used. The voxel volume is shown to have a large effect on the measured anisotropy but not the mean diffusivity. The elevation in diffusion anisotropy observed in acute stroke was then investigated using the eigenvalues of the diffusion tensor, and isotropic and anisotropic tensors. The second section addresses the relationship between gradient-echo and spin-echo dynamic-susceptibility-contrast measurements of cerebral perfusion. The basic contrast measurement is the diffusion of water through pseudo-random magnetic fields created by the injection of a contrast agent. Numerical simulations were used to elucidate the relationship between signal loss and biophysical variables, such as the vessel geometry, the blood volume, and the rate of water self-diffusion.615.84University of Cambridgehttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.599663Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 615.84
spellingShingle 615.84
Green, H. A. L.
Utilisation of the natural self-diffusion of water to make physiological measurements in human brain
description Magnetic resonance imaging enables the parameterisation of various physiological processes by comparison of a baseline set of images with a set of images taken after some perturbation of the nuclear spins. By linking this perturbation to a physiological process, changes in signal intensity become a proxy measure of that physiological process. This thesis is concerned with the accuracy and meaning of the measurements made using the natural self-diffusion of water. The first section deals with diffusion tensor measurements, which are three-dimensional measures of water self-diffusion using linear magnetic field gradients. The thesis looks in turn at the effect of signal noise, and partial volume effects on parameters such as the mean diffusivity, the eigenvalues and the fractional anisotropy of the diffusion tensor. The accuracy of the technique, as indicated by the results of numerical simulations, is compared to those acquired from phantom and brain imaging. These results provide an estimate of the dependence of diffusion measurements on technique. The coefficient of variation of diffusion measurements is shown to depend on the metric being used. The voxel volume is shown to have a large effect on the measured anisotropy but not the mean diffusivity. The elevation in diffusion anisotropy observed in acute stroke was then investigated using the eigenvalues of the diffusion tensor, and isotropic and anisotropic tensors. The second section addresses the relationship between gradient-echo and spin-echo dynamic-susceptibility-contrast measurements of cerebral perfusion. The basic contrast measurement is the diffusion of water through pseudo-random magnetic fields created by the injection of a contrast agent. Numerical simulations were used to elucidate the relationship between signal loss and biophysical variables, such as the vessel geometry, the blood volume, and the rate of water self-diffusion.
author Green, H. A. L.
author_facet Green, H. A. L.
author_sort Green, H. A. L.
title Utilisation of the natural self-diffusion of water to make physiological measurements in human brain
title_short Utilisation of the natural self-diffusion of water to make physiological measurements in human brain
title_full Utilisation of the natural self-diffusion of water to make physiological measurements in human brain
title_fullStr Utilisation of the natural self-diffusion of water to make physiological measurements in human brain
title_full_unstemmed Utilisation of the natural self-diffusion of water to make physiological measurements in human brain
title_sort utilisation of the natural self-diffusion of water to make physiological measurements in human brain
publisher University of Cambridge
publishDate 2004
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.599663
work_keys_str_mv AT greenhal utilisationofthenaturalselfdiffusionofwatertomakephysiologicalmeasurementsinhumanbrain
_version_ 1716794764401049600