White light interferometry in measurements of micro volumes

A procedure for measuring micro-volumes of solids with irregular and complex boundaries of both concave and convex forms has been developed. Advantages, limitations and potential applications of the developed procedure are identified and discussed. The precision of this procedure is demonstrated in...

Full description

Bibliographic Details
Main Author: Ferri, Carlo
Published: Cardiff University 2006
Subjects:
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.583806
id ndltd-bl.uk-oai-ethos.bl.uk-583806
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-5838062015-12-31T03:27:34ZWhite light interferometry in measurements of micro volumesFerri, Carlo2006A procedure for measuring micro-volumes of solids with irregular and complex boundaries of both concave and convex forms has been developed. Advantages, limitations and potential applications of the developed procedure are identified and discussed. The precision of this procedure is demonstrated in the case of a con vex form. In the light of the key role of metrology in the current trend toward product miniaturisation, the need for dedicating resources and effort to assessing quantitatively the performances of measuring processes is most apparent. The developed procedure is based on white light interferometric microscopy. In order to enable the deployment of this measuring system in the developed procedure and in agreement with the centrality of metrology mentioned above, an investigation of white light interferometric microscopy has been carried out from a user perspective. In particular, two sources of variability were identified and experimentally quantified and the precision in repeatability conditions was estimated when measuring length along the z-axis in a pre-specified micro-metric range. A critical analysis of the calibration procedure built in the investigated microscope has also been conducted. In order to overcome the pitfalls discovered in such an analysis, a spline-based calibration procedure has been developed and demonstrated. In addition, the control methods needed for the practical usage of the proposed calibration procedure have been developed. Calibration studies are made possible by the provision of traceable reference materials. Therefore, a cost-effective and versatile procedure for the build ing of traceable reference samples of length in the micrometric range was developed. The proposed method used standard gauge blocks commonly found in metrology laboratories.621.36Cardiff Universityhttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.583806http://orca.cf.ac.uk/54574/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 621.36
spellingShingle 621.36
Ferri, Carlo
White light interferometry in measurements of micro volumes
description A procedure for measuring micro-volumes of solids with irregular and complex boundaries of both concave and convex forms has been developed. Advantages, limitations and potential applications of the developed procedure are identified and discussed. The precision of this procedure is demonstrated in the case of a con vex form. In the light of the key role of metrology in the current trend toward product miniaturisation, the need for dedicating resources and effort to assessing quantitatively the performances of measuring processes is most apparent. The developed procedure is based on white light interferometric microscopy. In order to enable the deployment of this measuring system in the developed procedure and in agreement with the centrality of metrology mentioned above, an investigation of white light interferometric microscopy has been carried out from a user perspective. In particular, two sources of variability were identified and experimentally quantified and the precision in repeatability conditions was estimated when measuring length along the z-axis in a pre-specified micro-metric range. A critical analysis of the calibration procedure built in the investigated microscope has also been conducted. In order to overcome the pitfalls discovered in such an analysis, a spline-based calibration procedure has been developed and demonstrated. In addition, the control methods needed for the practical usage of the proposed calibration procedure have been developed. Calibration studies are made possible by the provision of traceable reference materials. Therefore, a cost-effective and versatile procedure for the build ing of traceable reference samples of length in the micrometric range was developed. The proposed method used standard gauge blocks commonly found in metrology laboratories.
author Ferri, Carlo
author_facet Ferri, Carlo
author_sort Ferri, Carlo
title White light interferometry in measurements of micro volumes
title_short White light interferometry in measurements of micro volumes
title_full White light interferometry in measurements of micro volumes
title_fullStr White light interferometry in measurements of micro volumes
title_full_unstemmed White light interferometry in measurements of micro volumes
title_sort white light interferometry in measurements of micro volumes
publisher Cardiff University
publishDate 2006
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.583806
work_keys_str_mv AT ferricarlo whitelightinterferometryinmeasurementsofmicrovolumes
_version_ 1718157817219645440