Design, test and biological validation of microfluidic systems for blood plasma separation

Sample preparation has been described as the weak link in microfluidics. In particular, plasma has to be extracted from whole blood for many analysis including protein analysis, cell-free DNA detection for prenatal diagnosis and transplant monitoring. The lack of suitable devices to perform the sepa...

Full description

Bibliographic Details
Main Author: Kersaudy-Kerhoas, Maiwenn
Other Authors: Dhariwal, Resh : Desmulliez, Marc
Published: Heriot-Watt University 2010
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.547709
id ndltd-bl.uk-oai-ethos.bl.uk-547709
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-5477092015-11-03T03:45:35ZDesign, test and biological validation of microfluidic systems for blood plasma separationKersaudy-Kerhoas, MaiwennDhariwal, Resh : Desmulliez, Marc2010Sample preparation has been described as the weak link in microfluidics. In particular, plasma has to be extracted from whole blood for many analysis including protein analysis, cell-free DNA detection for prenatal diagnosis and transplant monitoring. The lack of suitable devices to perform the separation at the microscale means that Lab On Chip (LOC) modules cannot be fully operated without sample preparation in a full-scale laboratory. In order to address this issue, blood flow in microchannels has been studied, and red blood cells behaviours in different geometrical environments have been classified. Several designs have been subsequently proposed to exploit some natural properties of blood flow and extract pure plasma without disturbing the cells. Furthermore, a high-level modelling method was developed to predict the behaviour of passive microfluidic networks. Additionally, the technique proposed provides useful guidance over the use of systems in more complex external environments. Experimental results have shown that plasma could be separated from undiluted whole blood in 10μm width microchannels at a flow rate of 2mL/hr. Using slightly larger structures (20μm) suitable for mass-manufacturing, diluted blood can be separated with 100% purity efficiency at high flow rate. An extensive biological validation of the extracted plasma was carried out to demonstrate its quality. To this effect Polymerase Chain Reaction (PCR) was performed to amplify targeted human genomic sequence from cell-free DNA present in the plasma. Furthermore, the influence of the sample dilution and separation efficiency on the amplification was characterised. It was shown that the sample dilution does have an influence on the amplification of house-keeping gene, but that amplification can be achieved even on high diluted samples. Additionally amplification can also be obtained on plasma samples with a range of separation efficiencies from 100% to 84%. In particular, two main points have been demonstrated (i) the extraction of plasma using combination of constrictions and bifurcations, (ii) the biological validation of the extracted plasma.Heriot-Watt Universityhttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.547709http://hdl.handle.net/10399/2365Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
description Sample preparation has been described as the weak link in microfluidics. In particular, plasma has to be extracted from whole blood for many analysis including protein analysis, cell-free DNA detection for prenatal diagnosis and transplant monitoring. The lack of suitable devices to perform the separation at the microscale means that Lab On Chip (LOC) modules cannot be fully operated without sample preparation in a full-scale laboratory. In order to address this issue, blood flow in microchannels has been studied, and red blood cells behaviours in different geometrical environments have been classified. Several designs have been subsequently proposed to exploit some natural properties of blood flow and extract pure plasma without disturbing the cells. Furthermore, a high-level modelling method was developed to predict the behaviour of passive microfluidic networks. Additionally, the technique proposed provides useful guidance over the use of systems in more complex external environments. Experimental results have shown that plasma could be separated from undiluted whole blood in 10μm width microchannels at a flow rate of 2mL/hr. Using slightly larger structures (20μm) suitable for mass-manufacturing, diluted blood can be separated with 100% purity efficiency at high flow rate. An extensive biological validation of the extracted plasma was carried out to demonstrate its quality. To this effect Polymerase Chain Reaction (PCR) was performed to amplify targeted human genomic sequence from cell-free DNA present in the plasma. Furthermore, the influence of the sample dilution and separation efficiency on the amplification was characterised. It was shown that the sample dilution does have an influence on the amplification of house-keeping gene, but that amplification can be achieved even on high diluted samples. Additionally amplification can also be obtained on plasma samples with a range of separation efficiencies from 100% to 84%. In particular, two main points have been demonstrated (i) the extraction of plasma using combination of constrictions and bifurcations, (ii) the biological validation of the extracted plasma.
author2 Dhariwal, Resh : Desmulliez, Marc
author_facet Dhariwal, Resh : Desmulliez, Marc
Kersaudy-Kerhoas, Maiwenn
author Kersaudy-Kerhoas, Maiwenn
spellingShingle Kersaudy-Kerhoas, Maiwenn
Design, test and biological validation of microfluidic systems for blood plasma separation
author_sort Kersaudy-Kerhoas, Maiwenn
title Design, test and biological validation of microfluidic systems for blood plasma separation
title_short Design, test and biological validation of microfluidic systems for blood plasma separation
title_full Design, test and biological validation of microfluidic systems for blood plasma separation
title_fullStr Design, test and biological validation of microfluidic systems for blood plasma separation
title_full_unstemmed Design, test and biological validation of microfluidic systems for blood plasma separation
title_sort design, test and biological validation of microfluidic systems for blood plasma separation
publisher Heriot-Watt University
publishDate 2010
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.547709
work_keys_str_mv AT kersaudykerhoasmaiwenn designtestandbiologicalvalidationofmicrofluidicsystemsforbloodplasmaseparation
_version_ 1718120841978314752