Can the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?

Introduction: Implantable defibrillators (ICD's) are currently unable to assess the haemodynamic stability of arrhythmias and can occasionally deliver intracardiac shocks when patients are conscious. We investigated the use of trans-ventricular impedance (across the left ventricle {LV}) as a ha...

Full description

Bibliographic Details
Main Author: Mudawi, Telal Omer Khalid
Other Authors: Kaye, Gerry C.
Published: University of Hull 2009
Subjects:
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.518632
id ndltd-bl.uk-oai-ethos.bl.uk-518632
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-5186322015-03-20T04:38:59ZCan the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?Mudawi, Telal Omer KhalidKaye, Gerry C.2009Introduction: Implantable defibrillators (ICD's) are currently unable to assess the haemodynamic stability of arrhythmias and can occasionally deliver intracardiac shocks when patients are conscious. We investigated the use of trans-ventricular impedance (across the left ventricle {LV}) as a haemodynamic sensor during arrhythmias in man. Methodology: Trans-ventricular LV impedance and systemic blood pressure (BP) were continuously monitored during clinical VT stimulation studies. LV impedance was measured by injecting a biphasic rectangular current pulse of 600|uA amplitude at a sampling rate of 128 Hz between the distal poles of a standard quadripolar pacing/recording electrode positioned at the right ventricular (RV) apex, and the proximal poles of a decapolar catheter positioned within the coronary sinus (CS). Current was injected using an external pacemaker (INOS, Biotronik) connected to the poles of the RV & CS catheters. Haemodynamically unstable arrhythmias were defined as those needing urgent DC cardioversion for loss of consciousness. Results: 28 patients were studied. Unstable VT: 5 (18%), Stable VT: 5 (18%), SVT: 2 (7%). During haemodynamically unstable VT, the stroke impedance (SZ) - the difference between the end systolic and end diastolic impedance values - dropped to 22% of its original sinus rhythm value (standard deviation = 15 - 32%), which was associated with a simultaneous drop in mean arterial BP down to 13% of its original sinus rhythm value (standard deviation = 3 - 36%), p <0.001. During haemodynamically stable VT, SZ dropped to 58% of its original sinus rhythm value (standard deviation = 33 - 88%), which was associated with a simultaneous drop in mean arterial BP down to 55% of its original sinus rhythm value (standard deviation = 24 - 77%), p = 0.008. Conclusion: Trans-ventricular impedance was able to assess the pumping efficacy of the heart during sinus rhythm, ventricular pacing and ventricular arrhythmias, and correlated well with changes in blood pressure, but was still unable to discriminate between haemodynamically stable and unstable arrhythmias. Further studies are needed to determine the long-term stability of trans-ventricular impedance measurement as a reliable haemodynamic sensor.616.1MedicineUniversity of Hullhttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.518632http://hydra.hull.ac.uk/resources/hull:5767Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 616.1
Medicine
spellingShingle 616.1
Medicine
Mudawi, Telal Omer Khalid
Can the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?
description Introduction: Implantable defibrillators (ICD's) are currently unable to assess the haemodynamic stability of arrhythmias and can occasionally deliver intracardiac shocks when patients are conscious. We investigated the use of trans-ventricular impedance (across the left ventricle {LV}) as a haemodynamic sensor during arrhythmias in man. Methodology: Trans-ventricular LV impedance and systemic blood pressure (BP) were continuously monitored during clinical VT stimulation studies. LV impedance was measured by injecting a biphasic rectangular current pulse of 600|uA amplitude at a sampling rate of 128 Hz between the distal poles of a standard quadripolar pacing/recording electrode positioned at the right ventricular (RV) apex, and the proximal poles of a decapolar catheter positioned within the coronary sinus (CS). Current was injected using an external pacemaker (INOS, Biotronik) connected to the poles of the RV & CS catheters. Haemodynamically unstable arrhythmias were defined as those needing urgent DC cardioversion for loss of consciousness. Results: 28 patients were studied. Unstable VT: 5 (18%), Stable VT: 5 (18%), SVT: 2 (7%). During haemodynamically unstable VT, the stroke impedance (SZ) - the difference between the end systolic and end diastolic impedance values - dropped to 22% of its original sinus rhythm value (standard deviation = 15 - 32%), which was associated with a simultaneous drop in mean arterial BP down to 13% of its original sinus rhythm value (standard deviation = 3 - 36%), p <0.001. During haemodynamically stable VT, SZ dropped to 58% of its original sinus rhythm value (standard deviation = 33 - 88%), which was associated with a simultaneous drop in mean arterial BP down to 55% of its original sinus rhythm value (standard deviation = 24 - 77%), p = 0.008. Conclusion: Trans-ventricular impedance was able to assess the pumping efficacy of the heart during sinus rhythm, ventricular pacing and ventricular arrhythmias, and correlated well with changes in blood pressure, but was still unable to discriminate between haemodynamically stable and unstable arrhythmias. Further studies are needed to determine the long-term stability of trans-ventricular impedance measurement as a reliable haemodynamic sensor.
author2 Kaye, Gerry C.
author_facet Kaye, Gerry C.
Mudawi, Telal Omer Khalid
author Mudawi, Telal Omer Khalid
author_sort Mudawi, Telal Omer Khalid
title Can the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?
title_short Can the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?
title_full Can the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?
title_fullStr Can the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?
title_full_unstemmed Can the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?
title_sort can the measurement of transventricular intracardiac impedance reliably differentiate haemodynamically stable from unstable arrhythmias?
publisher University of Hull
publishDate 2009
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.518632
work_keys_str_mv AT mudawitelalomerkhalid canthemeasurementoftransventricularintracardiacimpedancereliablydifferentiatehaemodynamicallystablefromunstablearrhythmias
_version_ 1716785907515785216