Multiplex detection for sexually transmitted infections using a novel electrochemical assay

Chlamydia trachomatis (Chlamydia) is the most common sexually transmitted infection diagnosed in genitourinary medicine (GUM) clinics and affects one in ten sexually active young people. Neisseria gonorrhoeae (gonorrhoea) is the second most common. They are asymptomatic in at least three-quarters of...

Full description

Bibliographic Details
Main Author: Olds, Jonathan
Other Authors: Jenkins, Andrew
Published: University of Bath 2008
Subjects:
Online Access:https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.507752
id ndltd-bl.uk-oai-ethos.bl.uk-507752
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-5077522019-03-14T03:24:49ZMultiplex detection for sexually transmitted infections using a novel electrochemical assayOlds, JonathanJenkins, Andrew2008Chlamydia trachomatis (Chlamydia) is the most common sexually transmitted infection diagnosed in genitourinary medicine (GUM) clinics and affects one in ten sexually active young people. Neisseria gonorrhoeae (gonorrhoea) is the second most common. They are asymptomatic in at least three-quarters of patients. Untreated infection can lead to serious health problems; including pelvic inflammatory disease and infertility in women. In men, it can cause urethritis and Reiter‟s Syndrome (arthritis). The number of diagnoses of uncomplicated chlamydia in GUM clinics in England increased by 288% between 1995 and 20061. Co infection with chlamydia and gonorrhoea is not uncommon. Up to half of patients diagnosed may be infected with both pathogens and, therefore, it is important to test sexually active individuals for both chlamydia and gonorrhoea using a multiplex system2. Electrochemical detection of specific DNA sequences offers advantages over established fluorescence techniques; including cost and ease of miniaturisation. The electrochemical gene sensor described here uniquely utilises enzymatic T7 Exonuclease digestion to generate ferrocenylated oligonucleotide fragments in a matched (gene sequence presence) sensor. These fragments exhibit a characteristically high response upon electrochemical analysis, using Differential Pulse Voltammetry and have been designed based on the ability to „tune‟ the oxidation potential of ferrocene by using electron-withdrawing and electron-donating substituent groups. Ferrocenylated oligonucleotide labels have been synthesised, each with a characteristic oxidation potential. Results from a study of the adsorption and electron transfer kinetics of T7 exonuclease - digested and undigested oligonucleotide redox probes at screen-printed carbon paste electrode (SCPE) surfaces will be considered as a basis for the assay discrimination. The high selectivity of the T7 Exonuclease digest is demonstrated using the ferrocenylated oligonucleotides and a triplex genomic electrochemical assay for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae and the human 7 beta-actin gene as an internal control for the assay using clinical samples will be presented.616.951University of Bathhttps://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.507752Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 616.951
spellingShingle 616.951
Olds, Jonathan
Multiplex detection for sexually transmitted infections using a novel electrochemical assay
description Chlamydia trachomatis (Chlamydia) is the most common sexually transmitted infection diagnosed in genitourinary medicine (GUM) clinics and affects one in ten sexually active young people. Neisseria gonorrhoeae (gonorrhoea) is the second most common. They are asymptomatic in at least three-quarters of patients. Untreated infection can lead to serious health problems; including pelvic inflammatory disease and infertility in women. In men, it can cause urethritis and Reiter‟s Syndrome (arthritis). The number of diagnoses of uncomplicated chlamydia in GUM clinics in England increased by 288% between 1995 and 20061. Co infection with chlamydia and gonorrhoea is not uncommon. Up to half of patients diagnosed may be infected with both pathogens and, therefore, it is important to test sexually active individuals for both chlamydia and gonorrhoea using a multiplex system2. Electrochemical detection of specific DNA sequences offers advantages over established fluorescence techniques; including cost and ease of miniaturisation. The electrochemical gene sensor described here uniquely utilises enzymatic T7 Exonuclease digestion to generate ferrocenylated oligonucleotide fragments in a matched (gene sequence presence) sensor. These fragments exhibit a characteristically high response upon electrochemical analysis, using Differential Pulse Voltammetry and have been designed based on the ability to „tune‟ the oxidation potential of ferrocene by using electron-withdrawing and electron-donating substituent groups. Ferrocenylated oligonucleotide labels have been synthesised, each with a characteristic oxidation potential. Results from a study of the adsorption and electron transfer kinetics of T7 exonuclease - digested and undigested oligonucleotide redox probes at screen-printed carbon paste electrode (SCPE) surfaces will be considered as a basis for the assay discrimination. The high selectivity of the T7 Exonuclease digest is demonstrated using the ferrocenylated oligonucleotides and a triplex genomic electrochemical assay for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae and the human 7 beta-actin gene as an internal control for the assay using clinical samples will be presented.
author2 Jenkins, Andrew
author_facet Jenkins, Andrew
Olds, Jonathan
author Olds, Jonathan
author_sort Olds, Jonathan
title Multiplex detection for sexually transmitted infections using a novel electrochemical assay
title_short Multiplex detection for sexually transmitted infections using a novel electrochemical assay
title_full Multiplex detection for sexually transmitted infections using a novel electrochemical assay
title_fullStr Multiplex detection for sexually transmitted infections using a novel electrochemical assay
title_full_unstemmed Multiplex detection for sexually transmitted infections using a novel electrochemical assay
title_sort multiplex detection for sexually transmitted infections using a novel electrochemical assay
publisher University of Bath
publishDate 2008
url https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.507752
work_keys_str_mv AT oldsjonathan multiplexdetectionforsexuallytransmittedinfectionsusinganovelelectrochemicalassay
_version_ 1719002245604835328