Chemometric methods for the analysis of process spectra using minimal reference data

To construct a spectroscopic multivariate calibration model, a set of representative mixture spectra (independent variables) and the corresponding reference values for the property of interest (dependent variables) must be obtained. For a dynamic system such as a batch or semi-batch chemical reactio...

Full description

Bibliographic Details
Main Author: Pedge, Nicholas Ian
Other Authors: Walmsley, Anthony
Published: University of Hull 2008
Subjects:
543
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.503733
id ndltd-bl.uk-oai-ethos.bl.uk-503733
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-5037332015-03-20T04:39:39ZChemometric methods for the analysis of process spectra using minimal reference dataPedge, Nicholas IanWalmsley, Anthony2008To construct a spectroscopic multivariate calibration model, a set of representative mixture spectra (independent variables) and the corresponding reference values for the property of interest (dependent variables) must be obtained. For a dynamic system such as a batch or semi-batch chemical reaction, creating such a data set may be very difficult or extremely time consuming. It may not be possible to create synthetic mixtures because reaction between the various reactants may occur. If the reaction proceeds via a reactive intermediate or affords a reactive product, isolated reference standards of those species may not be available. Reactions in industry are often heterogeneous and highly concentrated; sampling the batch throughout the course of the reaction for off-line analysis can be problematic and therefore introduce significant error into measured reference values. An alternative approach that combined Self-Modelling Curve Resolution (SMCR) methods and Partial Least Squares (PLS) to construct a quantitative model using only minimal reference data was implemented. The objective was to construct a quantitative calibration model to allow real-time in-situ UV/ATR measurements to be used to determine the end-point of a chlorination reaction. Difficult reaction sampling conditions and the absence of isolated reference standards for the product and reactive intermediate required the method to be developed using only a few key reference measurements.543ChemistryUniversity of Hullhttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.503733http://hydra.hull.ac.uk/resources/hull:1747Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 543
Chemistry
spellingShingle 543
Chemistry
Pedge, Nicholas Ian
Chemometric methods for the analysis of process spectra using minimal reference data
description To construct a spectroscopic multivariate calibration model, a set of representative mixture spectra (independent variables) and the corresponding reference values for the property of interest (dependent variables) must be obtained. For a dynamic system such as a batch or semi-batch chemical reaction, creating such a data set may be very difficult or extremely time consuming. It may not be possible to create synthetic mixtures because reaction between the various reactants may occur. If the reaction proceeds via a reactive intermediate or affords a reactive product, isolated reference standards of those species may not be available. Reactions in industry are often heterogeneous and highly concentrated; sampling the batch throughout the course of the reaction for off-line analysis can be problematic and therefore introduce significant error into measured reference values. An alternative approach that combined Self-Modelling Curve Resolution (SMCR) methods and Partial Least Squares (PLS) to construct a quantitative model using only minimal reference data was implemented. The objective was to construct a quantitative calibration model to allow real-time in-situ UV/ATR measurements to be used to determine the end-point of a chlorination reaction. Difficult reaction sampling conditions and the absence of isolated reference standards for the product and reactive intermediate required the method to be developed using only a few key reference measurements.
author2 Walmsley, Anthony
author_facet Walmsley, Anthony
Pedge, Nicholas Ian
author Pedge, Nicholas Ian
author_sort Pedge, Nicholas Ian
title Chemometric methods for the analysis of process spectra using minimal reference data
title_short Chemometric methods for the analysis of process spectra using minimal reference data
title_full Chemometric methods for the analysis of process spectra using minimal reference data
title_fullStr Chemometric methods for the analysis of process spectra using minimal reference data
title_full_unstemmed Chemometric methods for the analysis of process spectra using minimal reference data
title_sort chemometric methods for the analysis of process spectra using minimal reference data
publisher University of Hull
publishDate 2008
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.503733
work_keys_str_mv AT pedgenicholasian chemometricmethodsfortheanalysisofprocessspectrausingminimalreferencedata
_version_ 1716785873153949696