Application of multilevel inverter as shunt active power filter in three-phase three-wire power system

This research investigates application issues of the active power filter to three-phase three-wire systems, with unbalanced, distorted loads where the line impedance gives rise to voltage distortion at the point of common coupling. Five shunt active power filters are investigated: two-level, wye con...

Full description

Bibliographic Details
Main Author: Zhang, Huibin
Published: University of Strathclyde 2009
Subjects:
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.501797
id ndltd-bl.uk-oai-ethos.bl.uk-501797
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-5017972015-03-20T05:30:19ZApplication of multilevel inverter as shunt active power filter in three-phase three-wire power systemZhang, Huibin2009This research investigates application issues of the active power filter to three-phase three-wire systems, with unbalanced, distorted loads where the line impedance gives rise to voltage distortion at the point of common coupling. Five shunt active power filters are investigated: two-level, wye connected cascaded three and five level, and diode-clamped three and five level. Capabilities of the different shunt active power filter topologies to mitigate voltage/current distortion, compensate reactive power, and balance real power from the source are investigated. Results indicate that neutral point clamped multilevel inverters have advantages over wye cascaded multilevel inverters when operating under asymmetrical load conditions.621.3815324University of Strathclydehttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.501797Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 621.3815324
spellingShingle 621.3815324
Zhang, Huibin
Application of multilevel inverter as shunt active power filter in three-phase three-wire power system
description This research investigates application issues of the active power filter to three-phase three-wire systems, with unbalanced, distorted loads where the line impedance gives rise to voltage distortion at the point of common coupling. Five shunt active power filters are investigated: two-level, wye connected cascaded three and five level, and diode-clamped three and five level. Capabilities of the different shunt active power filter topologies to mitigate voltage/current distortion, compensate reactive power, and balance real power from the source are investigated. Results indicate that neutral point clamped multilevel inverters have advantages over wye cascaded multilevel inverters when operating under asymmetrical load conditions.
author Zhang, Huibin
author_facet Zhang, Huibin
author_sort Zhang, Huibin
title Application of multilevel inverter as shunt active power filter in three-phase three-wire power system
title_short Application of multilevel inverter as shunt active power filter in three-phase three-wire power system
title_full Application of multilevel inverter as shunt active power filter in three-phase three-wire power system
title_fullStr Application of multilevel inverter as shunt active power filter in three-phase three-wire power system
title_full_unstemmed Application of multilevel inverter as shunt active power filter in three-phase three-wire power system
title_sort application of multilevel inverter as shunt active power filter in three-phase three-wire power system
publisher University of Strathclyde
publishDate 2009
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.501797
work_keys_str_mv AT zhanghuibin applicationofmultilevelinverterasshuntactivepowerfilterinthreephasethreewirepowersystem
_version_ 1716791855033614336