The feasibility of using heart rate variability to detect distress

The objective of this work is to look at the feasibility of using heart rate variability analysis as a method of improving discrimination between those fetuses suffering distress and those not.;Heart rate variability analysis was applied to data acquired from rats who had undergone asphyxia for set...

Full description

Bibliographic Details
Main Author: Boardman, Anita
Published: University of Leicester 2003
Subjects:
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.488947
id ndltd-bl.uk-oai-ethos.bl.uk-488947
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-4889472016-12-08T03:27:02ZThe feasibility of using heart rate variability to detect distressBoardman, Anita2003The objective of this work is to look at the feasibility of using heart rate variability analysis as a method of improving discrimination between those fetuses suffering distress and those not.;Heart rate variability analysis was applied to data acquired from rats who had undergone asphyxia for set durations of up to 7 minutes. From analysis in both the time and frequency domain, it was possible to clearly identify the occurrence of the injury. Further correlations were made between these results, pH levels and neurological assessments for the different durations of asphyxia. It was found that during and following the injury, the pH and the heart rate decrease as expected, but the overall change in heart rate variability was much more pronounced. Some interesting results were also found for the shorter durations of asphyxia which will be looked at.;Fetal heart rate data was collected before and during labour in normal patients and variability analysis of the heart rate was performed. The acquisition of heart rate data using Doppler ultrasound is discussed and comparisons made between heart rate data acquired non-invasively using Doppler ultrasound and that acquired invasively using the scalp electrode during labour. It was found that providing the ultrasound signals did not suffer greater from noise, a reasonable comparison of beat-to-heat intervals and the time domain measure of heart rate variability was possible. The application of these results is discussed.;In conclusion, it has been found that it is feasible to detect asphyxial distress in rats using the standard deviation of 30 second intervals of heart beats. It has also been possible to collect fetal heart rate data and perform a similar heart rate variability analysis however further work needs to be undertaken to find out if this is predictive of distress in the fetus during labour.618.5University of Leicesterhttp://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.488947http://hdl.handle.net/2381/30206Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 618.5
spellingShingle 618.5
Boardman, Anita
The feasibility of using heart rate variability to detect distress
description The objective of this work is to look at the feasibility of using heart rate variability analysis as a method of improving discrimination between those fetuses suffering distress and those not.;Heart rate variability analysis was applied to data acquired from rats who had undergone asphyxia for set durations of up to 7 minutes. From analysis in both the time and frequency domain, it was possible to clearly identify the occurrence of the injury. Further correlations were made between these results, pH levels and neurological assessments for the different durations of asphyxia. It was found that during and following the injury, the pH and the heart rate decrease as expected, but the overall change in heart rate variability was much more pronounced. Some interesting results were also found for the shorter durations of asphyxia which will be looked at.;Fetal heart rate data was collected before and during labour in normal patients and variability analysis of the heart rate was performed. The acquisition of heart rate data using Doppler ultrasound is discussed and comparisons made between heart rate data acquired non-invasively using Doppler ultrasound and that acquired invasively using the scalp electrode during labour. It was found that providing the ultrasound signals did not suffer greater from noise, a reasonable comparison of beat-to-heat intervals and the time domain measure of heart rate variability was possible. The application of these results is discussed.;In conclusion, it has been found that it is feasible to detect asphyxial distress in rats using the standard deviation of 30 second intervals of heart beats. It has also been possible to collect fetal heart rate data and perform a similar heart rate variability analysis however further work needs to be undertaken to find out if this is predictive of distress in the fetus during labour.
author Boardman, Anita
author_facet Boardman, Anita
author_sort Boardman, Anita
title The feasibility of using heart rate variability to detect distress
title_short The feasibility of using heart rate variability to detect distress
title_full The feasibility of using heart rate variability to detect distress
title_fullStr The feasibility of using heart rate variability to detect distress
title_full_unstemmed The feasibility of using heart rate variability to detect distress
title_sort feasibility of using heart rate variability to detect distress
publisher University of Leicester
publishDate 2003
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.488947
work_keys_str_mv AT boardmananita thefeasibilityofusingheartratevariabilitytodetectdistress
AT boardmananita feasibilityofusingheartratevariabilitytodetectdistress
_version_ 1718400251820244992