The electrical impedance of stationary and moving blood and its clinical applications

This investigation is concerned with the unique property of blood, that its electrical impedance varies with flow. A review of past work on this topic shows that the factors upon which this variation depends have not been properly investigated, and for any clinical application, further knowledge of...

Full description

Bibliographic Details
Main Author: Frewer, R. A.
Published: University of Surrey 1975
Subjects:
612
Online Access:https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.455990
id ndltd-bl.uk-oai-ethos.bl.uk-455990
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-4559902018-09-11T03:20:02ZThe electrical impedance of stationary and moving blood and its clinical applicationsFrewer, R. A.1975This investigation is concerned with the unique property of blood, that its electrical impedance varies with flow. A review of past work on this topic shows that the factors upon which this variation depends have not been properly investigated, and for any clinical application, further knowledge of these factors is required. To this end, conductivity cells for use with flowing liquids were designed, and their electrode characteristics determined using saline solution, plasma and blood. This resulted in a new electrical circuit model being proposed. The impedances of samples of human blood were found as functions of a number of parameters. In the majority of tests results were obtained over a wide frequency range (from about 10 kHz to 8 MHz), enabling electrode polarization to be accounted for. These fairly high frequencies, made possible by the use of a transformer ratio-arm bridge, reduced electrode effects to reasonable values. The change in electrical impedance of blood with flow rate was examined as a function of flow tube bore, electrode disposition, temperature and erythrocyte concentration in addition to its dependence on frequency. Major findings concerned the dependence of this change on both bore of flow tube and electrode disposition. A critical examination of hypotheses previously suggested to explain the mechanism of this change, and also of the rheological properties of blood, together with experimental results described here, led to the proposition that viscosity dependence on shear rate is linked to electrical impedance change with flow rate. Thus it would be logical to regard blood impedance as a function of shear rate, as part of a new theory. Some clinical applications were suggested, and a small diameter catheter for detection and monitoring of flow in narrow arteries was investigated. It was shown that such a catheter would also enable measurements of bore of vessels to be obtained.612University of Surreyhttps://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.455990http://epubs.surrey.ac.uk/847448/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 612
spellingShingle 612
Frewer, R. A.
The electrical impedance of stationary and moving blood and its clinical applications
description This investigation is concerned with the unique property of blood, that its electrical impedance varies with flow. A review of past work on this topic shows that the factors upon which this variation depends have not been properly investigated, and for any clinical application, further knowledge of these factors is required. To this end, conductivity cells for use with flowing liquids were designed, and their electrode characteristics determined using saline solution, plasma and blood. This resulted in a new electrical circuit model being proposed. The impedances of samples of human blood were found as functions of a number of parameters. In the majority of tests results were obtained over a wide frequency range (from about 10 kHz to 8 MHz), enabling electrode polarization to be accounted for. These fairly high frequencies, made possible by the use of a transformer ratio-arm bridge, reduced electrode effects to reasonable values. The change in electrical impedance of blood with flow rate was examined as a function of flow tube bore, electrode disposition, temperature and erythrocyte concentration in addition to its dependence on frequency. Major findings concerned the dependence of this change on both bore of flow tube and electrode disposition. A critical examination of hypotheses previously suggested to explain the mechanism of this change, and also of the rheological properties of blood, together with experimental results described here, led to the proposition that viscosity dependence on shear rate is linked to electrical impedance change with flow rate. Thus it would be logical to regard blood impedance as a function of shear rate, as part of a new theory. Some clinical applications were suggested, and a small diameter catheter for detection and monitoring of flow in narrow arteries was investigated. It was shown that such a catheter would also enable measurements of bore of vessels to be obtained.
author Frewer, R. A.
author_facet Frewer, R. A.
author_sort Frewer, R. A.
title The electrical impedance of stationary and moving blood and its clinical applications
title_short The electrical impedance of stationary and moving blood and its clinical applications
title_full The electrical impedance of stationary and moving blood and its clinical applications
title_fullStr The electrical impedance of stationary and moving blood and its clinical applications
title_full_unstemmed The electrical impedance of stationary and moving blood and its clinical applications
title_sort electrical impedance of stationary and moving blood and its clinical applications
publisher University of Surrey
publishDate 1975
url https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.455990
work_keys_str_mv AT frewerra theelectricalimpedanceofstationaryandmovingbloodanditsclinicalapplications
AT frewerra electricalimpedanceofstationaryandmovingbloodanditsclinicalapplications
_version_ 1718732714533715968