The engineering and biology of femoral impaction grafting

Femoral impaction grafting is a technique where bone graft is impacted into the femur prior to cementing a stem in place. The technique is designed to compensate for bone stock loss in revision surgery, however it has associated problems of implant movement / subsidence and periprosthetic fractures....

Full description

Bibliographic Details
Main Author: Phipps, Kirsty
Published: University College London (University of London) 2005
Subjects:
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.415141
id ndltd-bl.uk-oai-ethos.bl.uk-415141
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-4151412016-08-04T03:30:17ZThe engineering and biology of femoral impaction graftingPhipps, Kirsty2005Femoral impaction grafting is a technique where bone graft is impacted into the femur prior to cementing a stem in place. The technique is designed to compensate for bone stock loss in revision surgery, however it has associated problems of implant movement / subsidence and periprosthetic fractures. The hypothesis for this thesis was that the stability and remodelling of impaction grafting could be improved, either by changing the graft size or by adding a synthetic graft. To quantify the technique of impaction grafting the Exeter slap hammer was modified, enabling force readings to be measured in nine surgical cases with four different surgeons. The results found that the average force that travels through the impactor is 1.8 to 8.4 kN, which is equivalent to three to eleven times body weight. These readings were used in the subsequent studies to replicate the current technique. It was hypothesised that varying the graft size might alter the porosity, strength and remodelling of impacted graft. Three graft groups were studied Small, Large and a Graded mix. The results found that the impacted Large graft had higher porosity and lower axial stiffness than the Small and Graded Graft. A noted reduction in graft density was found after six weeks in-vivo compared with twelve, irrespective of graft type. Since density can be related to mechanical strength this led to the question: Could the inclusion of a synthetic bone graft improve the mechanical properties of remodelling graft A 50:50 mix of allograft and BoneSave was compared with allograft. No difference in stiffness was found between the groups after six and twelve weeks remodelling. These studies were carried out using small test samples either in the laboratory or in- vivo. In order to determine if synthetic graft extenders could be used clinically tests in more realistic models were undertaken. Mechanical analysis was conducted on the 50 % inclusion of two graft extenders with allograft, namely: BoneSave and Appapore-60. The results of both projects showed a positive result.617.5820592University College London (University of London)http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.415141http://discovery.ucl.ac.uk/1445787/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 617.5820592
spellingShingle 617.5820592
Phipps, Kirsty
The engineering and biology of femoral impaction grafting
description Femoral impaction grafting is a technique where bone graft is impacted into the femur prior to cementing a stem in place. The technique is designed to compensate for bone stock loss in revision surgery, however it has associated problems of implant movement / subsidence and periprosthetic fractures. The hypothesis for this thesis was that the stability and remodelling of impaction grafting could be improved, either by changing the graft size or by adding a synthetic graft. To quantify the technique of impaction grafting the Exeter slap hammer was modified, enabling force readings to be measured in nine surgical cases with four different surgeons. The results found that the average force that travels through the impactor is 1.8 to 8.4 kN, which is equivalent to three to eleven times body weight. These readings were used in the subsequent studies to replicate the current technique. It was hypothesised that varying the graft size might alter the porosity, strength and remodelling of impacted graft. Three graft groups were studied Small, Large and a Graded mix. The results found that the impacted Large graft had higher porosity and lower axial stiffness than the Small and Graded Graft. A noted reduction in graft density was found after six weeks in-vivo compared with twelve, irrespective of graft type. Since density can be related to mechanical strength this led to the question: Could the inclusion of a synthetic bone graft improve the mechanical properties of remodelling graft A 50:50 mix of allograft and BoneSave was compared with allograft. No difference in stiffness was found between the groups after six and twelve weeks remodelling. These studies were carried out using small test samples either in the laboratory or in- vivo. In order to determine if synthetic graft extenders could be used clinically tests in more realistic models were undertaken. Mechanical analysis was conducted on the 50 % inclusion of two graft extenders with allograft, namely: BoneSave and Appapore-60. The results of both projects showed a positive result.
author Phipps, Kirsty
author_facet Phipps, Kirsty
author_sort Phipps, Kirsty
title The engineering and biology of femoral impaction grafting
title_short The engineering and biology of femoral impaction grafting
title_full The engineering and biology of femoral impaction grafting
title_fullStr The engineering and biology of femoral impaction grafting
title_full_unstemmed The engineering and biology of femoral impaction grafting
title_sort engineering and biology of femoral impaction grafting
publisher University College London (University of London)
publishDate 2005
url http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.415141
work_keys_str_mv AT phippskirsty theengineeringandbiologyoffemoralimpactiongrafting
AT phippskirsty engineeringandbiologyoffemoralimpactiongrafting
_version_ 1718369534979604480