The volume distribution of Tetrahymena elliotti : its measurement and application to growth parameter estimation

The volume distribution of a population of cells growing by binary fission is considered practically and theoretically. A mathematical model of the volume distribution of extant cells in a growing population is derived and compared to volume distributions obtained by optical means and by use of a Co...

Full description

Bibliographic Details
Main Author: Roberts, D. McL.
Published: University of Surrey 1982
Subjects:
590
Online Access:https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.257557
id ndltd-bl.uk-oai-ethos.bl.uk-257557
record_format oai_dc
spelling ndltd-bl.uk-oai-ethos.bl.uk-2575572018-09-11T03:19:06ZThe volume distribution of Tetrahymena elliotti : its measurement and application to growth parameter estimationRoberts, D. McL.1982The volume distribution of a population of cells growing by binary fission is considered practically and theoretically. A mathematical model of the volume distribution of extant cells in a growing population is derived and compared to volume distributions obtained by optical means and by use of a Coulter counter. The model has the same form as distributions obtained optically, but is substantially different from those measured with the Coulter counter. An examination of the mode of operation of the Coulter counter shows that its physical configuration leads to excessive skewness in the measured distributions. The use of an hydrodynamic focusing system produces distributions which agree in form with both the theoretical model and the optically derived volume distributions. The Coulter counter has been shown to underestimate the size of ciliates. The apparent shrinkage of the cells after dilution with saline solution is thought to be due to the permiability of the cell pellicle to electrical current. The mean size of cells measured with the Coulter counter is linearly related to the size measured microscopically. A novel method of assessing the skewness of volume distributions is developed. The relationship of skewness to growth rate is determined and discussed. The relationship between the mitotic index and the growth rate is derived for the first time. The batch growth of Tetrahymena elliotti has been studied in depth, and. it has been demonstrated that no stationary phase, in the classical sense, is developed. It is shown that there is significant cell cell death in cultures of T. elliotti, particularly in relation to sparged aeration and magnetic stirring. Continuous culture of T. elliotti failed to achieve steady states, whereas other microorganisms (T. pyriformis and Klebsiella pneumoniae) came to steady state in the same apparatus.590ZoologyUniversity of Surreyhttps://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.257557http://epubs.surrey.ac.uk/847949/Electronic Thesis or Dissertation
collection NDLTD
sources NDLTD
topic 590
Zoology
spellingShingle 590
Zoology
Roberts, D. McL.
The volume distribution of Tetrahymena elliotti : its measurement and application to growth parameter estimation
description The volume distribution of a population of cells growing by binary fission is considered practically and theoretically. A mathematical model of the volume distribution of extant cells in a growing population is derived and compared to volume distributions obtained by optical means and by use of a Coulter counter. The model has the same form as distributions obtained optically, but is substantially different from those measured with the Coulter counter. An examination of the mode of operation of the Coulter counter shows that its physical configuration leads to excessive skewness in the measured distributions. The use of an hydrodynamic focusing system produces distributions which agree in form with both the theoretical model and the optically derived volume distributions. The Coulter counter has been shown to underestimate the size of ciliates. The apparent shrinkage of the cells after dilution with saline solution is thought to be due to the permiability of the cell pellicle to electrical current. The mean size of cells measured with the Coulter counter is linearly related to the size measured microscopically. A novel method of assessing the skewness of volume distributions is developed. The relationship of skewness to growth rate is determined and discussed. The relationship between the mitotic index and the growth rate is derived for the first time. The batch growth of Tetrahymena elliotti has been studied in depth, and. it has been demonstrated that no stationary phase, in the classical sense, is developed. It is shown that there is significant cell cell death in cultures of T. elliotti, particularly in relation to sparged aeration and magnetic stirring. Continuous culture of T. elliotti failed to achieve steady states, whereas other microorganisms (T. pyriformis and Klebsiella pneumoniae) came to steady state in the same apparatus.
author Roberts, D. McL.
author_facet Roberts, D. McL.
author_sort Roberts, D. McL.
title The volume distribution of Tetrahymena elliotti : its measurement and application to growth parameter estimation
title_short The volume distribution of Tetrahymena elliotti : its measurement and application to growth parameter estimation
title_full The volume distribution of Tetrahymena elliotti : its measurement and application to growth parameter estimation
title_fullStr The volume distribution of Tetrahymena elliotti : its measurement and application to growth parameter estimation
title_full_unstemmed The volume distribution of Tetrahymena elliotti : its measurement and application to growth parameter estimation
title_sort volume distribution of tetrahymena elliotti : its measurement and application to growth parameter estimation
publisher University of Surrey
publishDate 1982
url https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.257557
work_keys_str_mv AT robertsdmcl thevolumedistributionoftetrahymenaelliottiitsmeasurementandapplicationtogrowthparameterestimation
AT robertsdmcl volumedistributionoftetrahymenaelliottiitsmeasurementandapplicationtogrowthparameterestimation
_version_ 1718732149869248512