Magnetically Actuated Electronics and Robotics for Medical Applications

abstract: Presented in this thesis are two projects that fall under the umbrella of magnetically actuated electronics and robotics for medical applications. First, magnetically actuated tunable soft electronics are discussed in Chapter 2. Wearable and implantable soft electronics are clinically avai...

Full description

Bibliographic Details
Other Authors: Edwards, Dakota (Author)
Format: Dissertation
Language:English
Published: 2020
Subjects:
Online Access:http://hdl.handle.net/2286/R.I.57115
id ndltd-asu.edu-item-57115
record_format oai_dc
spelling ndltd-asu.edu-item-571152020-06-02T03:01:16Z Magnetically Actuated Electronics and Robotics for Medical Applications abstract: Presented in this thesis are two projects that fall under the umbrella of magnetically actuated electronics and robotics for medical applications. First, magnetically actuated tunable soft electronics are discussed in Chapter 2. Wearable and implantable soft electronics are clinically available and commonplace. However, these devices can be taken a step further to improve the lives of their users by adding remote tunability. The four electric units tested were planar inductors, axial inductors, capacitors and resistors. The devices were made of polydimethylsiloxane (PDMS) for flexibility with copper components for conductivity. The units were tuned using magnets and mobile components comprised of iron filings and ferrofluid. The characteristic properties examined for each unit are as follows: inductance and quality factor (Q-factor) for inductors, capacitance and Q-factor for capacitors, and impedance for resistors. There were two groups of tuning tests: quantity effect and position effect of the mobile component. The position of the mobile component had a larger effect on each unit, with 20-23% change in inductance for inductors (from 3.31 µH for planar and 0.44 µH for axial), 12.7% from 2.854 pF for capacitors and 185.3% from 0.353 kΩ for resistors. Chapter 3 discusses a magnetic needle tracking device with operative assistance from a six degree-of-freedom robotic arm. Traditional needle steering faces many obstacles such as torsional effects, buckling, and small radii of curvature. To improve upon the concept, this project uses permanent magnets in parallel with a tracking system to steer and determine the position and orientation of the needle in real time. The magnet configuration is located at the end effector of the robotic arm. The trajectory of the end effector depends on the needle’s path, and vice versa. The distance the needle travels inside the workspace is tracked by a direct current (DC) motor, to which the needle is tethered. Combining this length with the pose of the end effector, the position and orientation of the needle can be calculated. Simulation of this tracking device has shown the functionality of the system. Testing has been done to confirm that a single magnet pulls the needle through the phantom tissue. Dissertation/Thesis Edwards, Dakota (Author) Marvi, Hamidreza (Advisor) Lee, Hyunglae (Committee member) Berman, Spring (Committee member) Arizona State University (Publisher) Mechanical engineering Medical Devices Needle Steering Robotics Soft Electronics Tracking eng 88 pages Masters Thesis Mechanical Engineering 2020 Masters Thesis http://hdl.handle.net/2286/R.I.57115 http://rightsstatements.org/vocab/InC/1.0/ 2020
collection NDLTD
language English
format Dissertation
sources NDLTD
topic Mechanical engineering
Medical Devices
Needle Steering
Robotics
Soft Electronics
Tracking
spellingShingle Mechanical engineering
Medical Devices
Needle Steering
Robotics
Soft Electronics
Tracking
Magnetically Actuated Electronics and Robotics for Medical Applications
description abstract: Presented in this thesis are two projects that fall under the umbrella of magnetically actuated electronics and robotics for medical applications. First, magnetically actuated tunable soft electronics are discussed in Chapter 2. Wearable and implantable soft electronics are clinically available and commonplace. However, these devices can be taken a step further to improve the lives of their users by adding remote tunability. The four electric units tested were planar inductors, axial inductors, capacitors and resistors. The devices were made of polydimethylsiloxane (PDMS) for flexibility with copper components for conductivity. The units were tuned using magnets and mobile components comprised of iron filings and ferrofluid. The characteristic properties examined for each unit are as follows: inductance and quality factor (Q-factor) for inductors, capacitance and Q-factor for capacitors, and impedance for resistors. There were two groups of tuning tests: quantity effect and position effect of the mobile component. The position of the mobile component had a larger effect on each unit, with 20-23% change in inductance for inductors (from 3.31 µH for planar and 0.44 µH for axial), 12.7% from 2.854 pF for capacitors and 185.3% from 0.353 kΩ for resistors. Chapter 3 discusses a magnetic needle tracking device with operative assistance from a six degree-of-freedom robotic arm. Traditional needle steering faces many obstacles such as torsional effects, buckling, and small radii of curvature. To improve upon the concept, this project uses permanent magnets in parallel with a tracking system to steer and determine the position and orientation of the needle in real time. The magnet configuration is located at the end effector of the robotic arm. The trajectory of the end effector depends on the needle’s path, and vice versa. The distance the needle travels inside the workspace is tracked by a direct current (DC) motor, to which the needle is tethered. Combining this length with the pose of the end effector, the position and orientation of the needle can be calculated. Simulation of this tracking device has shown the functionality of the system. Testing has been done to confirm that a single magnet pulls the needle through the phantom tissue. === Dissertation/Thesis === Masters Thesis Mechanical Engineering 2020
author2 Edwards, Dakota (Author)
author_facet Edwards, Dakota (Author)
title Magnetically Actuated Electronics and Robotics for Medical Applications
title_short Magnetically Actuated Electronics and Robotics for Medical Applications
title_full Magnetically Actuated Electronics and Robotics for Medical Applications
title_fullStr Magnetically Actuated Electronics and Robotics for Medical Applications
title_full_unstemmed Magnetically Actuated Electronics and Robotics for Medical Applications
title_sort magnetically actuated electronics and robotics for medical applications
publishDate 2020
url http://hdl.handle.net/2286/R.I.57115
_version_ 1719315752200175616