Retinal Photometer Final Design Review

The main objective of the retinal photometer is to detect visual changes in the retina before irreversible damage can occur. The handheld photometer is fitted with a small light source surrounded by a circular pattern of LEDs. The central LED is focused into the fovea of the retina by a single lens....

Full description

Bibliographic Details
Main Author: Castro, Layne Arin
Other Authors: Arabyan, Ara
Language:en
Published: The University of Arizona. 2013
Online Access:http://hdl.handle.net/10150/297519
id ndltd-arizona.edu-oai-arizona.openrepository.com-10150-297519
record_format oai_dc
spelling ndltd-arizona.edu-oai-arizona.openrepository.com-10150-2975192015-10-23T05:19:47Z Retinal Photometer Final Design Review Castro, Layne Arin Arabyan, Ara The main objective of the retinal photometer is to detect visual changes in the retina before irreversible damage can occur. The handheld photometer is fitted with a small light source surrounded by a circular pattern of LEDs. The central LED is focused into the fovea of the retina by a single lens. The lens can adjust to account for various visual acuities. The momentary light pulse induces photobleaching, a harmless process of temporarily blinding the fovea similar to the temporary blindness of walking into the sun after being in a dark space. The photometer will then record the amount of time it takes for full eyesight regeneration on the onboard LCD screen using a timer, which is programmed and wired through a self-contained circuit. Recovery times, interpreted by a medical professional, are shorter in healthy eyes than in eyes with macular degeneration. If increased response times are observed, a different lens can be inserted to decrease the spot size of the LED to pinpoint the severely damaged areas of the macula. Additionally, the circular pattern of LEDs tests visual sensitivities of off-center vision. Diabetic retinopathy or macular edema is likely if the patient cannot detect the full arrangement of LEDs. 2013 text Electronic Thesis http://hdl.handle.net/10150/297519 en Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author. The University of Arizona.
collection NDLTD
language en
sources NDLTD
description The main objective of the retinal photometer is to detect visual changes in the retina before irreversible damage can occur. The handheld photometer is fitted with a small light source surrounded by a circular pattern of LEDs. The central LED is focused into the fovea of the retina by a single lens. The lens can adjust to account for various visual acuities. The momentary light pulse induces photobleaching, a harmless process of temporarily blinding the fovea similar to the temporary blindness of walking into the sun after being in a dark space. The photometer will then record the amount of time it takes for full eyesight regeneration on the onboard LCD screen using a timer, which is programmed and wired through a self-contained circuit. Recovery times, interpreted by a medical professional, are shorter in healthy eyes than in eyes with macular degeneration. If increased response times are observed, a different lens can be inserted to decrease the spot size of the LED to pinpoint the severely damaged areas of the macula. Additionally, the circular pattern of LEDs tests visual sensitivities of off-center vision. Diabetic retinopathy or macular edema is likely if the patient cannot detect the full arrangement of LEDs.
author2 Arabyan, Ara
author_facet Arabyan, Ara
Castro, Layne Arin
author Castro, Layne Arin
spellingShingle Castro, Layne Arin
Retinal Photometer Final Design Review
author_sort Castro, Layne Arin
title Retinal Photometer Final Design Review
title_short Retinal Photometer Final Design Review
title_full Retinal Photometer Final Design Review
title_fullStr Retinal Photometer Final Design Review
title_full_unstemmed Retinal Photometer Final Design Review
title_sort retinal photometer final design review
publisher The University of Arizona.
publishDate 2013
url http://hdl.handle.net/10150/297519
work_keys_str_mv AT castrolaynearin retinalphotometerfinaldesignreview
_version_ 1718105156514480128