An Updated Telemetry System for Reliable Powering In Vivo Coupled to a Tablet Computer

Accurate and reliable in vivo measurement systems for orthopedic applications will allow a better understanding of native joint loading, gait patterns, and changes during healing and tissue regeneration. Robust and reliable telemetry units with an implantable transmitter and data acquisition softwar...

Full description

Bibliographic Details
Main Author: Ouellette, Jacalyn Lee
Other Authors: Szivek, John A.
Language:en
Published: The University of Arizona. 2013
Subjects:
Online Access:http://hdl.handle.net/10150/293645
id ndltd-arizona.edu-oai-arizona.openrepository.com-10150-293645
record_format oai_dc
spelling ndltd-arizona.edu-oai-arizona.openrepository.com-10150-2936452015-10-23T05:17:11Z An Updated Telemetry System for Reliable Powering In Vivo Coupled to a Tablet Computer Ouellette, Jacalyn Lee Szivek, John A. Bilgin, Ali Vande Geest, Jonathan Wenger, Karl Biomedical Engineering Accurate and reliable in vivo measurement systems for orthopedic applications will allow a better understanding of native joint loading, gait patterns, and changes during healing and tissue regeneration. Robust and reliable telemetry units with an implantable transmitter and data acquisition software are necessary to insure long-term measurements. It was the goal of this study to update the current implantable telemetry system. Updates included using a new tablet computer for increased rates of data acquisition and encasing transmitters in a new waterproof casing. Software was developed using Labview on a Windows based Acer Iconia Tab. The Labview program allowed the user to save data to a measurement file and view the data in real time. The increased processing power of the tablet resulted in an increase in data collection rates from 29Hz to 87Hz. Interfacing the tablet computer with the telemetry system required the use of a RS-232 protocol to USB adapter. The newly developed tablet computer system was also used for load measurement collection during the most recent in vivo study. In order to insure transmitter function in vivo it was necessary to characterize the factors affecting transmission in vivo and develop transmitter and power coil designs that operated reliably. In the past implantable transmitters were noted to operate properly during bench top testing, but often failed after being placed in vivo. The two factors studied that limited power transfer to the transmitters were immersion in an aqueous environment and exposure to elevated temperatures. An aqueous environment significantly decreased power transfer by 11.9% (p-value = 0.014) relative to testing on the bench top. Additionally, a temperature increase to 40°C decreased power transfer by 6.2% (p-value = 0.017) when compared to power transfer in room temperature air. A solution that restored transmitter function required encasing transmitters in a new waterproof casing. Different casing designs made of silicone and semi-solid triglycerides were developed and tested on the bench top. Two different casing designs were used during in vivo testing and implanted into test animals. One casing design insured transmission while the other separated in vivo and did not facilitate transmission. 2013 text Electronic Thesis http://hdl.handle.net/10150/293645 en Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author. The University of Arizona.
collection NDLTD
language en
sources NDLTD
topic Biomedical Engineering
spellingShingle Biomedical Engineering
Ouellette, Jacalyn Lee
An Updated Telemetry System for Reliable Powering In Vivo Coupled to a Tablet Computer
description Accurate and reliable in vivo measurement systems for orthopedic applications will allow a better understanding of native joint loading, gait patterns, and changes during healing and tissue regeneration. Robust and reliable telemetry units with an implantable transmitter and data acquisition software are necessary to insure long-term measurements. It was the goal of this study to update the current implantable telemetry system. Updates included using a new tablet computer for increased rates of data acquisition and encasing transmitters in a new waterproof casing. Software was developed using Labview on a Windows based Acer Iconia Tab. The Labview program allowed the user to save data to a measurement file and view the data in real time. The increased processing power of the tablet resulted in an increase in data collection rates from 29Hz to 87Hz. Interfacing the tablet computer with the telemetry system required the use of a RS-232 protocol to USB adapter. The newly developed tablet computer system was also used for load measurement collection during the most recent in vivo study. In order to insure transmitter function in vivo it was necessary to characterize the factors affecting transmission in vivo and develop transmitter and power coil designs that operated reliably. In the past implantable transmitters were noted to operate properly during bench top testing, but often failed after being placed in vivo. The two factors studied that limited power transfer to the transmitters were immersion in an aqueous environment and exposure to elevated temperatures. An aqueous environment significantly decreased power transfer by 11.9% (p-value = 0.014) relative to testing on the bench top. Additionally, a temperature increase to 40°C decreased power transfer by 6.2% (p-value = 0.017) when compared to power transfer in room temperature air. A solution that restored transmitter function required encasing transmitters in a new waterproof casing. Different casing designs made of silicone and semi-solid triglycerides were developed and tested on the bench top. Two different casing designs were used during in vivo testing and implanted into test animals. One casing design insured transmission while the other separated in vivo and did not facilitate transmission.
author2 Szivek, John A.
author_facet Szivek, John A.
Ouellette, Jacalyn Lee
author Ouellette, Jacalyn Lee
author_sort Ouellette, Jacalyn Lee
title An Updated Telemetry System for Reliable Powering In Vivo Coupled to a Tablet Computer
title_short An Updated Telemetry System for Reliable Powering In Vivo Coupled to a Tablet Computer
title_full An Updated Telemetry System for Reliable Powering In Vivo Coupled to a Tablet Computer
title_fullStr An Updated Telemetry System for Reliable Powering In Vivo Coupled to a Tablet Computer
title_full_unstemmed An Updated Telemetry System for Reliable Powering In Vivo Coupled to a Tablet Computer
title_sort updated telemetry system for reliable powering in vivo coupled to a tablet computer
publisher The University of Arizona.
publishDate 2013
url http://hdl.handle.net/10150/293645
work_keys_str_mv AT ouellettejacalynlee anupdatedtelemetrysystemforreliablepoweringinvivocoupledtoatabletcomputer
AT ouellettejacalynlee updatedtelemetrysystemforreliablepoweringinvivocoupledtoatabletcomputer
_version_ 1718104797396074496