MECHANICAL CHARACTERIZATION OF METALLIC NANOWIRES BY USING A CUSTOMIZED ATOMIC MICROSCOPE

A new experimental method to characterize the mechanical properties of metallic nanowires is introduced. An accurate and fast mechanical characterization of nanowires requires simultaneous imaging and testing of nanowires. However, there exists no practical experimental procedure in the literature...

Full description

Bibliographic Details
Main Author: Celik, Emrah
Other Authors: Madenci, Erdogan
Language:en
Published: The University of Arizona. 2010
Subjects:
Online Access:http://hdl.handle.net/10150/195425
id ndltd-arizona.edu-oai-arizona.openrepository.com-10150-195425
record_format oai_dc
spelling ndltd-arizona.edu-oai-arizona.openrepository.com-10150-1954252015-10-23T04:42:39Z MECHANICAL CHARACTERIZATION OF METALLIC NANOWIRES BY USING A CUSTOMIZED ATOMIC MICROSCOPE Celik, Emrah Madenci, Erdogan Madenci, Erdogan Madenci, Erdogan Palusinski, Olgierd Enikov, Eniko Wu, Xiaoyi Vujosevic, Milena Atomic Force Microscope Finite Element Analysis Mechanical Properties Nanowire Peridynamics A new experimental method to characterize the mechanical properties of metallic nanowires is introduced. An accurate and fast mechanical characterization of nanowires requires simultaneous imaging and testing of nanowires. However, there exists no practical experimental procedure in the literature that provides a quantitative mechanical analysis and imaging of the nanowire specimens during mechanical testing. In this study, a customized atomic force microscope (AFM) is placed inside a scanning electron microscope (SEM) in order to locate the position of the nanowires. The tip of the atomic force microscope cantilever is utilized to bend and break the nanowires. The nanowires are prepared by electroplating of nickel ions into the nanoscale pores of the alumina membranes. Force versus bending displacement responses of these nanowires are measured experimentally and then compared against those of the finite element analysis and peridynamic simulations to extract their mechanical properties through an inverse approach.The average elastic modulus of nickel nanowires, which are extracted using finite element analysis and peridynamic simulations, varies between 220 GPa and 225 GPa. The elastic modulus of bulk nickel published in the literature is comparable to that of nickel nanowires. This observation agrees well with the previous findings on nanowires stating that the elastic modulus of nanowires with diameters over 100nm is similar to that of bulk counterparts. The average yield stress of nickel nanowires, which are extracted using finite element analysis and peridynamic simulations, is found to be between 3.6 GPa to 4.1 GPa. The average value of yield stress of nickel nanowires with 250nm diameter is significantly higher than that of bulk nickel. Higher yield stress of nickel nanowires observed in this study can be explained by the lower defect density of nickel nanowires when compared to their bulk counterparts.Deviation in the extracted mechanical properties is investigated by analyzing the major sources of uncertainty in the experimental procedure. The effects of the nanowire orientation, the loading position and the nanowire diameter on the mechanical test results are quantified using ANSYS simulations. Among all of these three sources of uncertainty investigated, the nanowire diameter has been found to have the most significant effect on the extracted mechanical properties. 2010 text Electronic Dissertation http://hdl.handle.net/10150/195425 752261148 11301 en Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author. The University of Arizona.
collection NDLTD
language en
sources NDLTD
topic Atomic Force Microscope
Finite Element Analysis
Mechanical Properties
Nanowire
Peridynamics
spellingShingle Atomic Force Microscope
Finite Element Analysis
Mechanical Properties
Nanowire
Peridynamics
Celik, Emrah
MECHANICAL CHARACTERIZATION OF METALLIC NANOWIRES BY USING A CUSTOMIZED ATOMIC MICROSCOPE
description A new experimental method to characterize the mechanical properties of metallic nanowires is introduced. An accurate and fast mechanical characterization of nanowires requires simultaneous imaging and testing of nanowires. However, there exists no practical experimental procedure in the literature that provides a quantitative mechanical analysis and imaging of the nanowire specimens during mechanical testing. In this study, a customized atomic force microscope (AFM) is placed inside a scanning electron microscope (SEM) in order to locate the position of the nanowires. The tip of the atomic force microscope cantilever is utilized to bend and break the nanowires. The nanowires are prepared by electroplating of nickel ions into the nanoscale pores of the alumina membranes. Force versus bending displacement responses of these nanowires are measured experimentally and then compared against those of the finite element analysis and peridynamic simulations to extract their mechanical properties through an inverse approach.The average elastic modulus of nickel nanowires, which are extracted using finite element analysis and peridynamic simulations, varies between 220 GPa and 225 GPa. The elastic modulus of bulk nickel published in the literature is comparable to that of nickel nanowires. This observation agrees well with the previous findings on nanowires stating that the elastic modulus of nanowires with diameters over 100nm is similar to that of bulk counterparts. The average yield stress of nickel nanowires, which are extracted using finite element analysis and peridynamic simulations, is found to be between 3.6 GPa to 4.1 GPa. The average value of yield stress of nickel nanowires with 250nm diameter is significantly higher than that of bulk nickel. Higher yield stress of nickel nanowires observed in this study can be explained by the lower defect density of nickel nanowires when compared to their bulk counterparts.Deviation in the extracted mechanical properties is investigated by analyzing the major sources of uncertainty in the experimental procedure. The effects of the nanowire orientation, the loading position and the nanowire diameter on the mechanical test results are quantified using ANSYS simulations. Among all of these three sources of uncertainty investigated, the nanowire diameter has been found to have the most significant effect on the extracted mechanical properties.
author2 Madenci, Erdogan
author_facet Madenci, Erdogan
Celik, Emrah
author Celik, Emrah
author_sort Celik, Emrah
title MECHANICAL CHARACTERIZATION OF METALLIC NANOWIRES BY USING A CUSTOMIZED ATOMIC MICROSCOPE
title_short MECHANICAL CHARACTERIZATION OF METALLIC NANOWIRES BY USING A CUSTOMIZED ATOMIC MICROSCOPE
title_full MECHANICAL CHARACTERIZATION OF METALLIC NANOWIRES BY USING A CUSTOMIZED ATOMIC MICROSCOPE
title_fullStr MECHANICAL CHARACTERIZATION OF METALLIC NANOWIRES BY USING A CUSTOMIZED ATOMIC MICROSCOPE
title_full_unstemmed MECHANICAL CHARACTERIZATION OF METALLIC NANOWIRES BY USING A CUSTOMIZED ATOMIC MICROSCOPE
title_sort mechanical characterization of metallic nanowires by using a customized atomic microscope
publisher The University of Arizona.
publishDate 2010
url http://hdl.handle.net/10150/195425
work_keys_str_mv AT celikemrah mechanicalcharacterizationofmetallicnanowiresbyusingacustomizedatomicmicroscope
_version_ 1718099560959574016