Measured temperature profiles to evaluate recharge In the semiarid southwest

Natural recharge is one of the most poorly constrained components of the water budget. In semiarid environments, quantifying natural recharge is difficult due to the relatively low fluxes and the thick unsaturated zones. Measuring deep recharge to great depths in multiple locations is impractical an...

Full description

Bibliographic Details
Main Author: Dowman, Charles E.
Other Authors: Ferre, P. A. Ty
Language:en
Published: The University of Arizona. 2002
Online Access:http://hdl.handle.net/10150/191369
id ndltd-arizona.edu-oai-arizona.openrepository.com-10150-191369
record_format oai_dc
spelling ndltd-arizona.edu-oai-arizona.openrepository.com-10150-1913692015-10-23T04:37:08Z Measured temperature profiles to evaluate recharge In the semiarid southwest Dowman, Charles E. Ferre, P. A. Ty Natural recharge is one of the most poorly constrained components of the water budget. In semiarid environments, quantifying natural recharge is difficult due to the relatively low fluxes and the thick unsaturated zones. Measuring deep recharge to great depths in multiple locations is impractical and cost prohibitive for most measurement methods. An alternative method to estimate deep percolation utilizes temperature profiles measured from the ground surface to the water table. Temperature measurements taken in existing cased wells provide an economical and useful vantage for accessing many locations within a basin. A controlled infiltration experiment was conducted to test the feasibility of using downhole temperature measurements to estimate the infiltration flux. VS2DHI (Healy and Ronan, 1996), an interactive numerical model, was used to predict and interpret coupled water-flow and heat-transport occurring in the subsurface during infiltration and redistribution. A sequential sensitivity analysis showed that downhole temperature profiles were most sensitive to the temperature of the applied water, the water flux, and the heat capacity of the dry soil. This downhole temperature method was extended to a natural setting. Temperature profiles were measured at six sites within the Tucson Basin. The temperature profiles varied throughout the basin, and the factors affecting the temperature profiles were numerous. Profiles from the in-channel and intrabasin boreholes showed effects of focused recharge, mountain-front recharge, and stream-channel recharge. Results suggest that this temperature method may be transferable to other basins in semiarid regions. 2002 Thesis-Reproduction (electronic) text http://hdl.handle.net/10150/191369 226258256 en Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author. The University of Arizona.
collection NDLTD
language en
sources NDLTD
description Natural recharge is one of the most poorly constrained components of the water budget. In semiarid environments, quantifying natural recharge is difficult due to the relatively low fluxes and the thick unsaturated zones. Measuring deep recharge to great depths in multiple locations is impractical and cost prohibitive for most measurement methods. An alternative method to estimate deep percolation utilizes temperature profiles measured from the ground surface to the water table. Temperature measurements taken in existing cased wells provide an economical and useful vantage for accessing many locations within a basin. A controlled infiltration experiment was conducted to test the feasibility of using downhole temperature measurements to estimate the infiltration flux. VS2DHI (Healy and Ronan, 1996), an interactive numerical model, was used to predict and interpret coupled water-flow and heat-transport occurring in the subsurface during infiltration and redistribution. A sequential sensitivity analysis showed that downhole temperature profiles were most sensitive to the temperature of the applied water, the water flux, and the heat capacity of the dry soil. This downhole temperature method was extended to a natural setting. Temperature profiles were measured at six sites within the Tucson Basin. The temperature profiles varied throughout the basin, and the factors affecting the temperature profiles were numerous. Profiles from the in-channel and intrabasin boreholes showed effects of focused recharge, mountain-front recharge, and stream-channel recharge. Results suggest that this temperature method may be transferable to other basins in semiarid regions.
author2 Ferre, P. A. Ty
author_facet Ferre, P. A. Ty
Dowman, Charles E.
author Dowman, Charles E.
spellingShingle Dowman, Charles E.
Measured temperature profiles to evaluate recharge In the semiarid southwest
author_sort Dowman, Charles E.
title Measured temperature profiles to evaluate recharge In the semiarid southwest
title_short Measured temperature profiles to evaluate recharge In the semiarid southwest
title_full Measured temperature profiles to evaluate recharge In the semiarid southwest
title_fullStr Measured temperature profiles to evaluate recharge In the semiarid southwest
title_full_unstemmed Measured temperature profiles to evaluate recharge In the semiarid southwest
title_sort measured temperature profiles to evaluate recharge in the semiarid southwest
publisher The University of Arizona.
publishDate 2002
url http://hdl.handle.net/10150/191369
work_keys_str_mv AT dowmancharlese measuredtemperatureprofilestoevaluaterechargeinthesemiaridsouthwest
_version_ 1718098546056495104