ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER.
Two identical instruments have been developed for use in the field to make radiometric measurements. They have been described as spectropolarimeters because of their ability to make polarization measurements in narrow spectral passbands. They have been used as part of a NASA sponsored project to mon...
Main Author: | |
---|---|
Other Authors: | |
Language: | en |
Published: |
The University of Arizona.
1985
|
Subjects: | |
Online Access: | http://hdl.handle.net/10150/188026 |
id |
ndltd-arizona.edu-oai-arizona.openrepository.com-10150-188026 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-arizona.edu-oai-arizona.openrepository.com-10150-1880262015-11-21T03:00:57Z ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER. CASTLE, KENNETH ROBERT. Slater, Philip N. Palmer, James M. Ionization of gases. Hydrogen-ion concentration. Hydrogen -- Isotopes. Two identical instruments have been developed for use in the field to make radiometric measurements. They have been described as spectropolarimeters because of their ability to make polarization measurements in narrow spectral passbands. They have been used as part of a NASA sponsored project to monitor the spectral and temporal response of the thematic mapper satellites. These satellites allow many natural and man-tended resources to be monitored over years of time, thus allowing their use to be planned for in the future. The dissertation discusses the design, fabrication, testing and absolute radiometric calibration of these spectropolarimeter instruments. The outstanding feature of these instruments are that they have been calibrated absolutely, for radiance measurements, to an accuracy of 2% - 3%, in the range of 400 nm to 1040 nm over selected spectral passbands. Previously, field measurements were considered good if they had an absolute accuracy of 10%, implying that the present accuracies are advancing the state-of-the-art for field instrument calibrations. These improved accuracies are the result of using two recently developed calibration standards, both of which use detector based methods. These standards are the Electrically Calibrated Pyroelectric Radiometer (ECPR), and the QED-100 quad detector. The end of the dissertation discusses the attempts made to verify that the accuracies claimed are indeed valid, and it is the author's belief that these accuracies have been verified completely. 1985 text Dissertation-Reproduction (electronic) http://hdl.handle.net/10150/188026 696621163 8525590 en Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author. The University of Arizona. |
collection |
NDLTD |
language |
en |
sources |
NDLTD |
topic |
Ionization of gases. Hydrogen-ion concentration. Hydrogen -- Isotopes. |
spellingShingle |
Ionization of gases. Hydrogen-ion concentration. Hydrogen -- Isotopes. CASTLE, KENNETH ROBERT. ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER. |
description |
Two identical instruments have been developed for use in the field to make radiometric measurements. They have been described as spectropolarimeters because of their ability to make polarization measurements in narrow spectral passbands. They have been used as part of a NASA sponsored project to monitor the spectral and temporal response of the thematic mapper satellites. These satellites allow many natural and man-tended resources to be monitored over years of time, thus allowing their use to be planned for in the future. The dissertation discusses the design, fabrication, testing and absolute radiometric calibration of these spectropolarimeter instruments. The outstanding feature of these instruments are that they have been calibrated absolutely, for radiance measurements, to an accuracy of 2% - 3%, in the range of 400 nm to 1040 nm over selected spectral passbands. Previously, field measurements were considered good if they had an absolute accuracy of 10%, implying that the present accuracies are advancing the state-of-the-art for field instrument calibrations. These improved accuracies are the result of using two recently developed calibration standards, both of which use detector based methods. These standards are the Electrically Calibrated Pyroelectric Radiometer (ECPR), and the QED-100 quad detector. The end of the dissertation discusses the attempts made to verify that the accuracies claimed are indeed valid, and it is the author's belief that these accuracies have been verified completely. |
author2 |
Slater, Philip N. |
author_facet |
Slater, Philip N. CASTLE, KENNETH ROBERT. |
author |
CASTLE, KENNETH ROBERT. |
author_sort |
CASTLE, KENNETH ROBERT. |
title |
ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER. |
title_short |
ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER. |
title_full |
ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER. |
title_fullStr |
ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER. |
title_full_unstemmed |
ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER. |
title_sort |
absolute radiometric calibration of a spectropolarimeter. |
publisher |
The University of Arizona. |
publishDate |
1985 |
url |
http://hdl.handle.net/10150/188026 |
work_keys_str_mv |
AT castlekennethrobert absoluteradiometriccalibrationofaspectropolarimeter |
_version_ |
1718133531740209152 |