Extending the measurement range of an optical surface profiler.

This dissertation investigates a method for extending the measurement range of an optical surface profiling instrument. The instrument examined in these experiments is a computer-controlled phase-modulated interference microscope. Because of its ability to measure surfaces with a high degree of vert...

Full description

Bibliographic Details
Main Author: Cochran, Eugene Rowland, III.
Other Authors: Wyant, James C.
Language:en
Published: The University of Arizona. 1988
Subjects:
Online Access:http://hdl.handle.net/10150/184531
id ndltd-arizona.edu-oai-arizona.openrepository.com-10150-184531
record_format oai_dc
spelling ndltd-arizona.edu-oai-arizona.openrepository.com-10150-1845312015-10-23T04:29:50Z Extending the measurement range of an optical surface profiler. Cochran, Eugene Rowland, III. Wyant, James C. Flatness measurement. Interference microscopes. This dissertation investigates a method for extending the measurement range of an optical surface profiling instrument. The instrument examined in these experiments is a computer-controlled phase-modulated interference microscope. Because of its ability to measure surfaces with a high degree of vertical resolution as well as excellent lateral resolution, this instrument is one of the most favorable candidates for determining the microtopography of optical surfaces. However, the data acquired by the instrument are restricted to a finite lateral and vertical range. To overcome this restriction, the feasibility of a new testing technique is explored. By overlapping a series of collinear profiles the limited field of view of this instrument can be increased and profiles that contain longer surface wavelengths can be examined. This dissertation also presents a method to augment both the vertical and horizontal dynamic range of the surface profiler by combining multiple subapertures and two-wavelength techniques. The theory, algorithms, error sources, and limitations encountered when concatenating a number of profiles are presented. In particular, the effects of accumulated piston and tilt errors on a measurement are explored. Some practical considerations for implementation and integration into an existing system are presented. Experimental findings and results of Monte Carlo simulations are also studied to explain the effects of random noise, lateral position errors, and defocus across the CCD array on measurement results. These results indicate the extent to which the field of view of the profiler may be augmented. A review of current methods of measuring surface topography is included, to provide for a more coherent text, along with a summary of pertinent measurement parameters for surface characterization. This work concludes with recommendations for future work that would make subaperture-testing techniques more reliable for measuring the microsurface structure of a material over an extended region. 1988 text Dissertation-Reproduction (electronic) http://hdl.handle.net/10150/184531 701549510 8902397 en Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author. The University of Arizona.
collection NDLTD
language en
sources NDLTD
topic Flatness measurement.
Interference microscopes.
spellingShingle Flatness measurement.
Interference microscopes.
Cochran, Eugene Rowland, III.
Extending the measurement range of an optical surface profiler.
description This dissertation investigates a method for extending the measurement range of an optical surface profiling instrument. The instrument examined in these experiments is a computer-controlled phase-modulated interference microscope. Because of its ability to measure surfaces with a high degree of vertical resolution as well as excellent lateral resolution, this instrument is one of the most favorable candidates for determining the microtopography of optical surfaces. However, the data acquired by the instrument are restricted to a finite lateral and vertical range. To overcome this restriction, the feasibility of a new testing technique is explored. By overlapping a series of collinear profiles the limited field of view of this instrument can be increased and profiles that contain longer surface wavelengths can be examined. This dissertation also presents a method to augment both the vertical and horizontal dynamic range of the surface profiler by combining multiple subapertures and two-wavelength techniques. The theory, algorithms, error sources, and limitations encountered when concatenating a number of profiles are presented. In particular, the effects of accumulated piston and tilt errors on a measurement are explored. Some practical considerations for implementation and integration into an existing system are presented. Experimental findings and results of Monte Carlo simulations are also studied to explain the effects of random noise, lateral position errors, and defocus across the CCD array on measurement results. These results indicate the extent to which the field of view of the profiler may be augmented. A review of current methods of measuring surface topography is included, to provide for a more coherent text, along with a summary of pertinent measurement parameters for surface characterization. This work concludes with recommendations for future work that would make subaperture-testing techniques more reliable for measuring the microsurface structure of a material over an extended region.
author2 Wyant, James C.
author_facet Wyant, James C.
Cochran, Eugene Rowland, III.
author Cochran, Eugene Rowland, III.
author_sort Cochran, Eugene Rowland, III.
title Extending the measurement range of an optical surface profiler.
title_short Extending the measurement range of an optical surface profiler.
title_full Extending the measurement range of an optical surface profiler.
title_fullStr Extending the measurement range of an optical surface profiler.
title_full_unstemmed Extending the measurement range of an optical surface profiler.
title_sort extending the measurement range of an optical surface profiler.
publisher The University of Arizona.
publishDate 1988
url http://hdl.handle.net/10150/184531
work_keys_str_mv AT cochraneugenerowlandiii extendingthemeasurementrangeofanopticalsurfaceprofiler
_version_ 1718097385943465984