Flow through a partially blocked artery downstream of a stented region

A numerical analysis of flow through a stenosed artery downstream of a stented region is presented. Three different Food and Drug Administration (FDA) approved stents (Bx Velocity, NIR, and Multilink Zeta) are considered in analyzing pressure drop and flow rates at the blockage and outlet of artery....

Full description

Bibliographic Details
Main Author: Gogineni, Aneesha
Other Authors: Ravigururajan, Tiruvadi S.
Format: Others
Language:en_US
Published: Wichita State University 2012
Subjects:
Online Access:http://hdl.handle.net/10057/5047
id ndltd-WICHITA-oai-soar.wichita.edu-10057-5047
record_format oai_dc
spelling ndltd-WICHITA-oai-soar.wichita.edu-10057-50472013-04-19T21:00:09ZFlow through a partially blocked artery downstream of a stented regionGogineni, AneeshaElectronic dissertationsA numerical analysis of flow through a stenosed artery downstream of a stented region is presented. Three different Food and Drug Administration (FDA) approved stents (Bx Velocity, NIR, and Multilink Zeta) are considered in analyzing pressure drop and flow rates at the blockage and outlet of artery. Blood flow inside the artery is assumed to be steady. The inlet pressures are defined as the mean arterial pressures in the stented artery using all stages of blood pressures. The pressure drop and volumetric flow rate increases at the blocked artery with increase in mean arterial pressures. In contrast to the previous results the pressure drop and volumetric flow rates decreases at the narrow end of the artery. A comparison was made between all the three different stents which determines the highly optimum stent geometry. An unsteady flow analysis is performed using NIR stent since it is proved to highly optimum when compared to other stents. The velocity and mass flow rates at the outlet are relatively high for unsteady flow rates when compared to steady flow rates. A grid independence study was also performed for all the three stents for accuracy. The obtained results can be used in determining the restenosis rates in patients after NIR stent implantation.Thesis (M.S.)--Wichita State University, College of Engineering, Dept. of Mechanical Engineering.Wichita State UniversityRavigururajan, Tiruvadi S.2012-04-02T20:34:23Z2012-04-02T20:34:23Z20112011-07Thesisxi, 63 p.t11064http://hdl.handle.net/10057/5047en_US© Copyright 2011 by Aneesha Gogineni. All rights reserved
collection NDLTD
language en_US
format Others
sources NDLTD
topic Electronic dissertations
spellingShingle Electronic dissertations
Gogineni, Aneesha
Flow through a partially blocked artery downstream of a stented region
description A numerical analysis of flow through a stenosed artery downstream of a stented region is presented. Three different Food and Drug Administration (FDA) approved stents (Bx Velocity, NIR, and Multilink Zeta) are considered in analyzing pressure drop and flow rates at the blockage and outlet of artery. Blood flow inside the artery is assumed to be steady. The inlet pressures are defined as the mean arterial pressures in the stented artery using all stages of blood pressures. The pressure drop and volumetric flow rate increases at the blocked artery with increase in mean arterial pressures. In contrast to the previous results the pressure drop and volumetric flow rates decreases at the narrow end of the artery. A comparison was made between all the three different stents which determines the highly optimum stent geometry. An unsteady flow analysis is performed using NIR stent since it is proved to highly optimum when compared to other stents. The velocity and mass flow rates at the outlet are relatively high for unsteady flow rates when compared to steady flow rates. A grid independence study was also performed for all the three stents for accuracy. The obtained results can be used in determining the restenosis rates in patients after NIR stent implantation. === Thesis (M.S.)--Wichita State University, College of Engineering, Dept. of Mechanical Engineering.
author2 Ravigururajan, Tiruvadi S.
author_facet Ravigururajan, Tiruvadi S.
Gogineni, Aneesha
author Gogineni, Aneesha
author_sort Gogineni, Aneesha
title Flow through a partially blocked artery downstream of a stented region
title_short Flow through a partially blocked artery downstream of a stented region
title_full Flow through a partially blocked artery downstream of a stented region
title_fullStr Flow through a partially blocked artery downstream of a stented region
title_full_unstemmed Flow through a partially blocked artery downstream of a stented region
title_sort flow through a partially blocked artery downstream of a stented region
publisher Wichita State University
publishDate 2012
url http://hdl.handle.net/10057/5047
work_keys_str_mv AT goginenianeesha flowthroughapartiallyblockedarterydownstreamofastentedregion
_version_ 1716583190546612224