Quantifying the Response of Relative Brain/Skull Motion to Rotational Input in the PMHS Head
Post-mortem human surrogate (PMHS) head specimens were subjected to two different angular speed pulses. Each pulse was approximately a half-sine with either a peak angular speed of either 40 or 20 rad/s and duration of either 30 or 60 milliseconds. High-speed biplane x-ray was used to record the mot...