Municipal sludge dewatering using a belt filter press

Experiments were performed on alum, anaerobically digested and aerobically digested sludges to determine the optimum polymer conditioning for a belt filter press The optimum polymer dosages for all three zones of a belt filter press were compared with each other to determine the best overall conditi...

Full description

Bibliographic Details
Main Author: Reitz, Daniel D.
Other Authors: Environmental Engineering
Format: Others
Language:en_US
Published: Virginia Polytechnic Institute and State University 2015
Subjects:
Online Access:http://hdl.handle.net/10919/53178
Description
Summary:Experiments were performed on alum, anaerobically digested and aerobically digested sludges to determine the optimum polymer conditioning for a belt filter press The optimum polymer dosages for all three zones of a belt filter press were compared with each other to determine the best overall conditioning. The requirements of all three zones of a belt filter press were the same. However, the gravity rate of drainage seems to under predict the dosages for optimum belt filter press performance. In addition the total mixing energy, G (the shear) and t (the mixing time), that represents the laboratory belt filter press was found to be approximately 45,000. Using a mixing energy input of 45,000 and a standard Buchner funnel apparatus the correct polymer dose for the belt filter press can be predicted. === Master of Science