Rapid bioluminometric enumeration of microorganisms in ground beef

Use of the bioluminometric ATP assay was evaluated for estimating total bacterial counts in ground beef. Minimum sensitivity was found to be 10⁶ cfu/g using a double filtration procedure for sample preparation. Although ATP content per cfu decreased approximately 10 fold during storage, correlation...

Full description

Bibliographic Details
Main Author: Cook, Frederick K.
Other Authors: Food Science and Technology
Format: Others
Language:en_US
Published: Virginia Polytechnic Institute and State University 2015
Subjects:
Online Access:http://hdl.handle.net/10919/51933
id ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-51933
record_format oai_dc
spelling ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-519332020-12-23T05:32:29Z Rapid bioluminometric enumeration of microorganisms in ground beef Cook, Frederick K. Food Science and Technology LD5655.V856 1988.C664 Cooking (Beef) -- Analysis Food -- Microbiology Use of the bioluminometric ATP assay was evaluated for estimating total bacterial counts in ground beef. Minimum sensitivity was found to be 10⁶ cfu/g using a double filtration procedure for sample preparation. Although ATP content per cfu decreased approximately 10 fold during storage, correlation of total aerobic plate count (APC) with microbial ATP content was 0.96. Selective non-microbial ATP extraction with ATPase treatment was evaluated for use in conjunction with the double filtration procedure to increase assay sensitivity. The new method was effective for removing additional non-microbial ATP without reducing ATP in bacteria. Estimated APC values were generally accurate to within ±0.50 log for ground beef samples above the detection limit of 5 x 10⁴ cfu/g. ATPase treatment increased sensitivity of the ATP assay and APC estimation by about 1 log while increasing assay time by 40 minutes, for a total of 60 minutes for 4 samples assayed in triplicate. The ATP assay was evaluated for use with ground beef patties inoculated with mixed ground beef spoilage flora, <i>Pseudomonas</i>, or <i>Lactobacillus</i> and stored at 2°C or 10°C using oxygen permeable or impermeable (vacuum) packaging. Excellent correlation (r²=0.95) was obtained for each inoculum and storage condition over the range of 5 x 10⁴ to 1 x 10⁹ cfu/g, when estimated APC values were compared with experimentally observed APC values. Usefulness of the ATP assay for estimating APC values of frozen ground beef was evaluated. Retail ground beef and <i>Lactobacillus</i>- and <i>Pseudomonas</i>-inoculated beef were frozen and thawed at different rates and examined for APC and microbial ATP content. Results indicated that, although freezing and thawing lowered numbers of <i>Pseudomonas</i>, APC values and microbial ATP content closely correlated. APC estimates were generally accurate to within 1/2 log. The importance of using an ATP assay standard to correct for variable enzyme activity and presence of quenching factors was demonstrated, and improved formulae were developed for optimum assay standard use. Alternate regression methods were evaluated for estimation of APC values but did not yield enhanced accuracy. Only one regression equation was needed for estimating APC values of ground beef containing different types of bacteria stored in various ways. Therefore, little knowledge of ground beef history is needed in order to rapidly and accurately estimate microbial numbers in ground beef using the bioluminometric ATP assay. Ph. D. 2015-04-29T18:30:56Z 2015-04-29T18:30:56Z 1988 Dissertation Text http://hdl.handle.net/10919/51933 en_US OCLC# 19730700 In Copyright http://rightsstatements.org/vocab/InC/1.0/ v, 161 leaves application/pdf application/pdf Virginia Polytechnic Institute and State University
collection NDLTD
language en_US
format Others
sources NDLTD
topic LD5655.V856 1988.C664
Cooking (Beef) -- Analysis
Food -- Microbiology
spellingShingle LD5655.V856 1988.C664
Cooking (Beef) -- Analysis
Food -- Microbiology
Cook, Frederick K.
Rapid bioluminometric enumeration of microorganisms in ground beef
description Use of the bioluminometric ATP assay was evaluated for estimating total bacterial counts in ground beef. Minimum sensitivity was found to be 10⁶ cfu/g using a double filtration procedure for sample preparation. Although ATP content per cfu decreased approximately 10 fold during storage, correlation of total aerobic plate count (APC) with microbial ATP content was 0.96. Selective non-microbial ATP extraction with ATPase treatment was evaluated for use in conjunction with the double filtration procedure to increase assay sensitivity. The new method was effective for removing additional non-microbial ATP without reducing ATP in bacteria. Estimated APC values were generally accurate to within ±0.50 log for ground beef samples above the detection limit of 5 x 10⁴ cfu/g. ATPase treatment increased sensitivity of the ATP assay and APC estimation by about 1 log while increasing assay time by 40 minutes, for a total of 60 minutes for 4 samples assayed in triplicate. The ATP assay was evaluated for use with ground beef patties inoculated with mixed ground beef spoilage flora, <i>Pseudomonas</i>, or <i>Lactobacillus</i> and stored at 2°C or 10°C using oxygen permeable or impermeable (vacuum) packaging. Excellent correlation (r²=0.95) was obtained for each inoculum and storage condition over the range of 5 x 10⁴ to 1 x 10⁹ cfu/g, when estimated APC values were compared with experimentally observed APC values. Usefulness of the ATP assay for estimating APC values of frozen ground beef was evaluated. Retail ground beef and <i>Lactobacillus</i>- and <i>Pseudomonas</i>-inoculated beef were frozen and thawed at different rates and examined for APC and microbial ATP content. Results indicated that, although freezing and thawing lowered numbers of <i>Pseudomonas</i>, APC values and microbial ATP content closely correlated. APC estimates were generally accurate to within 1/2 log. The importance of using an ATP assay standard to correct for variable enzyme activity and presence of quenching factors was demonstrated, and improved formulae were developed for optimum assay standard use. Alternate regression methods were evaluated for estimation of APC values but did not yield enhanced accuracy. Only one regression equation was needed for estimating APC values of ground beef containing different types of bacteria stored in various ways. Therefore, little knowledge of ground beef history is needed in order to rapidly and accurately estimate microbial numbers in ground beef using the bioluminometric ATP assay. === Ph. D.
author2 Food Science and Technology
author_facet Food Science and Technology
Cook, Frederick K.
author Cook, Frederick K.
author_sort Cook, Frederick K.
title Rapid bioluminometric enumeration of microorganisms in ground beef
title_short Rapid bioluminometric enumeration of microorganisms in ground beef
title_full Rapid bioluminometric enumeration of microorganisms in ground beef
title_fullStr Rapid bioluminometric enumeration of microorganisms in ground beef
title_full_unstemmed Rapid bioluminometric enumeration of microorganisms in ground beef
title_sort rapid bioluminometric enumeration of microorganisms in ground beef
publisher Virginia Polytechnic Institute and State University
publishDate 2015
url http://hdl.handle.net/10919/51933
work_keys_str_mv AT cookfrederickk rapidbioluminometricenumerationofmicroorganismsingroundbeef
_version_ 1719371261029646336