An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs

Expanding the standard, single-well recording geometry used to monitor seismicity during hydro-fracture treatments could provide more accurate hypocenter locations and seismic velocities, improving general reservoir characterization. However, for the real, two-well data set obtained for this projec...

Full description

Bibliographic Details
Main Author: Gilliland, Ellen
Other Authors: Geosciences
Format: Others
Published: Virginia Tech 2014
Subjects:
Online Access:http://hdl.handle.net/10919/45325
http://scholar.lib.vt.edu/theses/available/etd-10272009-165453/
id ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-45325
record_format oai_dc
spelling ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-453252021-03-16T05:32:28Z An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs Gilliland, Ellen Geosciences Hole, John A. Weiss, Chester J. Chapman, Martin C. hydro-fracture treatment hypocenter location error hypocenter inversion algorithm multi-well survey velocity structure arrival-time picking error geometric constraint Expanding the standard, single-well recording geometry used to monitor seismicity during hydro-fracture treatments could provide more accurate hypocenter locations and seismic velocities, improving general reservoir characterization. However, for the real, two-well data set obtained for this project, only S-wave picks were available, and testing resulted in anomalous hypocenter location behavior. This study uses a hypocenter location algorithm and both real and synthetic data sets to investigate how the accuracy of the velocity model, starting hypocenter location, recording geometry, and arrival-time picking error affect final hypocenter locations. Hypocenter locations improved using a velocity model that closely matched the observed sonic log rather than a smoothed version of this model. The starting hypocenter location did not affect the final location solution if both starting and final locations were between the wells. Two solutions were possible when the true solution was not directly between the wells. Adding realistic random picking errors to synthetic data closely modeled the dispersed hypocenter error pattern observed in the real data results. Adding data from a third well to synthetic tests dramatically reduced location error and removed horizontal geometric bias observed in the two-well case. Seismic event data recorded during hydro-fracture treatments could potentially be used for three-dimensional joint hypocenter-velocity tomography. This would require observation wells close enough to earthquakes to record P- and S-wave arrivals or wells at orientations sufficient to properly triangulate hypocenter locations. Simulating results with synthetic tests before drilling could optimize survey design to collect data more effectively and make analysis more useful. Master of Science 2014-03-14T21:48:15Z 2014-03-14T21:48:15Z 2009-10-14 2009-10-27 2009-11-17 2009-11-17 Thesis etd-10272009-165453 http://hdl.handle.net/10919/45325 http://scholar.lib.vt.edu/theses/available/etd-10272009-165453/ Gilliland_ES_T_2009.pdf In Copyright http://rightsstatements.org/vocab/InC/1.0/ application/pdf Virginia Tech
collection NDLTD
format Others
sources NDLTD
topic hydro-fracture treatment
hypocenter location error
hypocenter inversion algorithm
multi-well survey
velocity structure
arrival-time picking error
geometric constraint
spellingShingle hydro-fracture treatment
hypocenter location error
hypocenter inversion algorithm
multi-well survey
velocity structure
arrival-time picking error
geometric constraint
Gilliland, Ellen
An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs
description Expanding the standard, single-well recording geometry used to monitor seismicity during hydro-fracture treatments could provide more accurate hypocenter locations and seismic velocities, improving general reservoir characterization. However, for the real, two-well data set obtained for this project, only S-wave picks were available, and testing resulted in anomalous hypocenter location behavior. This study uses a hypocenter location algorithm and both real and synthetic data sets to investigate how the accuracy of the velocity model, starting hypocenter location, recording geometry, and arrival-time picking error affect final hypocenter locations. Hypocenter locations improved using a velocity model that closely matched the observed sonic log rather than a smoothed version of this model. The starting hypocenter location did not affect the final location solution if both starting and final locations were between the wells. Two solutions were possible when the true solution was not directly between the wells. Adding realistic random picking errors to synthetic data closely modeled the dispersed hypocenter error pattern observed in the real data results. Adding data from a third well to synthetic tests dramatically reduced location error and removed horizontal geometric bias observed in the two-well case. Seismic event data recorded during hydro-fracture treatments could potentially be used for three-dimensional joint hypocenter-velocity tomography. This would require observation wells close enough to earthquakes to record P- and S-wave arrivals or wells at orientations sufficient to properly triangulate hypocenter locations. Simulating results with synthetic tests before drilling could optimize survey design to collect data more effectively and make analysis more useful. === Master of Science
author2 Geosciences
author_facet Geosciences
Gilliland, Ellen
author Gilliland, Ellen
author_sort Gilliland, Ellen
title An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs
title_short An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs
title_full An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs
title_fullStr An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs
title_full_unstemmed An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs
title_sort assessment of hypocenter errors associated with the seismic monitoring of induced hydro-fracturing in hydrocarbon reservoirs
publisher Virginia Tech
publishDate 2014
url http://hdl.handle.net/10919/45325
http://scholar.lib.vt.edu/theses/available/etd-10272009-165453/
work_keys_str_mv AT gillilandellen anassessmentofhypocentererrorsassociatedwiththeseismicmonitoringofinducedhydrofracturinginhydrocarbonreservoirs
AT gillilandellen assessmentofhypocentererrorsassociatedwiththeseismicmonitoringofinducedhydrofracturinginhydrocarbonreservoirs
_version_ 1719383790816591872